Biological and dosimetric effect of the number of beams for radiotherapy plans of breast cancer patients. Z. Mansour1, Ehab M. Attalla 2, Ibrahim A. Awad 3 M.I. Abdel Hamid 4 and A. Sarhan 5

Q3 Health Professions Iranian Journal of Medical Physics Pub Date : 2021-05-13 DOI:10.22038/IJMP.2021.55487.1919
Zezy Mansour, A. Ehab, A. Sarhan, Ebrahim Awad, M. Ismail
{"title":"Biological and dosimetric effect of the number of beams for radiotherapy plans of breast cancer patients. Z. Mansour1, Ehab M. Attalla 2, Ibrahim A. Awad 3 M.I. Abdel Hamid 4 and A. Sarhan 5","authors":"Zezy Mansour, A. Ehab, A. Sarhan, Ebrahim Awad, M. Ismail","doi":"10.22038/IJMP.2021.55487.1919","DOIUrl":null,"url":null,"abstract":"Aim: To evaluate the biologic differences in treatment plans, the dosimetric outcome with different number of beams on 3D conformal radiotherapy for breast cancer patients as well as evaluate the outcome of plans with more number of fields compared with less number of fields for irradiation of breast cancer patients then determine the optimum plan through dosimetric and biological parameters. The study included 13 of the female breast cancer patients who were irradiated, after surgery. The tumor and the organs at risk were delineated. Then for every patient two plans of increasing and decreasing the number of beams were done. The DVH of each plan was analyzed based on the calculating the TCP and NTCP by MATLAB and calculating the dosemetrical parameters such as CI and HI. Results: All the results representing the following parameters V105% , V95% ,V110%, D mean , D max CI, HI and D5% are the same in both more and less number of beams . All the results also showed that the average TCP% of PTV of the plans that contains more numbers of beams is 54.27 % while in other plans 54.65%. Mean± SEM of group (a) is 54.27 ± 1.121 while in group b is 54.65 ± 0.9297 N=13. This show that there is no significance in the group (a) (increasing numbers of beams) versus group (b) (less numbers of beam) means that the tumor control by increasing the number of beams is nearly the same as decreasing the number, b value = ( 0.7964). This occurred in the rest of the parametersRadio oncologist and medical physicist must make a decision about treatment though the accurate values of TCP and NTCP and this achieved via testing plans by MATLAP program not by the number of beams.","PeriodicalId":14613,"journal":{"name":"Iranian Journal of Medical Physics","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Medical Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22038/IJMP.2021.55487.1919","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: To evaluate the biologic differences in treatment plans, the dosimetric outcome with different number of beams on 3D conformal radiotherapy for breast cancer patients as well as evaluate the outcome of plans with more number of fields compared with less number of fields for irradiation of breast cancer patients then determine the optimum plan through dosimetric and biological parameters. The study included 13 of the female breast cancer patients who were irradiated, after surgery. The tumor and the organs at risk were delineated. Then for every patient two plans of increasing and decreasing the number of beams were done. The DVH of each plan was analyzed based on the calculating the TCP and NTCP by MATLAB and calculating the dosemetrical parameters such as CI and HI. Results: All the results representing the following parameters V105% , V95% ,V110%, D mean , D max CI, HI and D5% are the same in both more and less number of beams . All the results also showed that the average TCP% of PTV of the plans that contains more numbers of beams is 54.27 % while in other plans 54.65%. Mean± SEM of group (a) is 54.27 ± 1.121 while in group b is 54.65 ± 0.9297 N=13. This show that there is no significance in the group (a) (increasing numbers of beams) versus group (b) (less numbers of beam) means that the tumor control by increasing the number of beams is nearly the same as decreasing the number, b value = ( 0.7964). This occurred in the rest of the parametersRadio oncologist and medical physicist must make a decision about treatment though the accurate values of TCP and NTCP and this achieved via testing plans by MATLAP program not by the number of beams.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
乳腺癌患者放疗计划中光束数的生物学和剂量学效应。Z. Mansour1, Ehab M. Attalla 2, Ibrahim A. Awad 3, M.I. Abdel Hamid 4, A. Sarhan 5
目的:评价癌症患者三维适形放射治疗方案的生物学差异、不同射束数的剂量测量结果,以及癌症患者多照射野与少照射野方案的结果,通过剂量测量和生物学参数确定最佳方案。这项研究包括13名癌症女性患者,她们在手术后接受了放射治疗。对肿瘤和危险器官进行了描绘。然后,为每个患者制定两个增加和减少波束数量的计划。通过MATLAB计算TCP和NTCP,并计算CI和HI等剂量测量参数,对各方案的DVH进行了分析。结果:表示以下参数V105%、V95%、V110%、D均值、D最大CI、HI和D5%的所有结果在或多或少的光束数量中都是相同的。结果还表明,多波束方案的PTV平均TCP%为54.27%,其他方案为54.65%。(a)组的平均±SEM为54.27±1.121,(b)组为54.65±0.9297 N=13。这表明在组(a)(增加波束数量)与组(b)(减少波束数量)中没有显著性意味着通过增加波束数量的肿瘤控制与减少数量几乎相同,b值=(0.7964)。这发生在其他参数中。无线电肿瘤学家和医学物理学家必须通过TCP和NTCP的准确值来决定治疗,这是通过MATLAP程序的测试计划而不是通过波束数量来实现的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Iranian Journal of Medical Physics
Iranian Journal of Medical Physics Health Professions-Radiological and Ultrasound Technology
CiteScore
1.00
自引率
0.00%
发文量
0
审稿时长
8 weeks
期刊介绍: Iranian Journal of Medical Physics (IJMP) is the official scientific bimonthly publication of the Iranian Association of Medical Physicists. IJMP is an international and multidisciplinary journal, peer review, free of charge publication and open access. This journal devoted to publish Original Papers, Review Articles, Short Communications, Technical Notes, Editorial and Letters to the Editor in the field of “Medical Physics” involving both basic and clinical research. Submissions of manuscript from all countries are welcome and will be reviewed by at least two expert reviewers.
期刊最新文献
Secondary cancer risk after radiotherapy of seminoma stage one The effect of cobalt oxide nanoparticles on improving the quality of CT and PET scan medical imaging Scatter radiation absorbed dose distribution in coronary angiography: A measurement based study Evaluation of Low-Dose 3D skull CT images in craniosynostosis Left-sided Breast Cancer Radiotherapy and Risk of Heart Diseases: with Considering Baseline Risk of Heart Diseases
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1