M. Krakowiak, P. Sokal, Marcin Rusinek, Marcin Rudaś
{"title":"Comparison of the O-arm and C-arm guided pedicle screws placement","authors":"M. Krakowiak, P. Sokal, Marcin Rusinek, Marcin Rudaś","doi":"10.31373/ejtcm/154811","DOIUrl":null,"url":null,"abstract":"Background: Transpedicular screw placement remains the gold standard technique for stabilization of the lum - bar spine. Material and methods: This is a retrospective study that analyzes patients that underwent the spinal stabilization surgical procedure. We compared results from two independent neurosurgical centers. In the years 2012-2015, the O-arm and StealthStation neuronavigation system was used for implantation of transpedicular screws. From 2018 to 2020 the transcutaneous pedicle screw placement procedure was performed using a standard C-arm device. Results: In 208 procedures performed with the O-arm device, the accuracy of screw position was 98.08%. Screw repositioning was necessary in 1.92% of all cases. In the 30 procedures that were performed using the C-arm, the accuracy of the screws was 86.7% and the screw reposition procedure acco - unted for 10% (in one case screws were not replaced due to clinical sequelae). Conclusions: Our data show that the spinal fusion with the O-arm tool has more accuracy, thus might be more indicated in procedures that require minimally invasive spinal stabilization.","PeriodicalId":52409,"journal":{"name":"European Journal of Translational and Clinical Medicine","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-12-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Translational and Clinical Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31373/ejtcm/154811","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Transpedicular screw placement remains the gold standard technique for stabilization of the lum - bar spine. Material and methods: This is a retrospective study that analyzes patients that underwent the spinal stabilization surgical procedure. We compared results from two independent neurosurgical centers. In the years 2012-2015, the O-arm and StealthStation neuronavigation system was used for implantation of transpedicular screws. From 2018 to 2020 the transcutaneous pedicle screw placement procedure was performed using a standard C-arm device. Results: In 208 procedures performed with the O-arm device, the accuracy of screw position was 98.08%. Screw repositioning was necessary in 1.92% of all cases. In the 30 procedures that were performed using the C-arm, the accuracy of the screws was 86.7% and the screw reposition procedure acco - unted for 10% (in one case screws were not replaced due to clinical sequelae). Conclusions: Our data show that the spinal fusion with the O-arm tool has more accuracy, thus might be more indicated in procedures that require minimally invasive spinal stabilization.