Development and Validation GC/MS Method for Methamphetamine Analysis in Urine by Miniaturization QuEChERS

Q2 Pharmacology, Toxicology and Pharmaceutics Science and Technology Indonesia Pub Date : 2023-07-06 DOI:10.26554/sti.2023.8.3.451-460
Soraya Aulia, R. Primaharinastiti, D. Purwanto
{"title":"Development and Validation GC/MS Method for Methamphetamine Analysis in Urine by Miniaturization QuEChERS","authors":"Soraya Aulia, R. Primaharinastiti, D. Purwanto","doi":"10.26554/sti.2023.8.3.451-460","DOIUrl":null,"url":null,"abstract":"This paper explains the development of a quick and easy gas chromatography (GC) approach to identify methamphetamine in urine. This research used gas chromatography with mass spectroscopy and a capillary column TG-5SILMS (5% phenyl methyl siloxane, 30 m x 0.32 x 25 m). The carrier gas flow rate was set at 1.0 mL/minute, the temperature inlet and detector had been set at 300°C, and the oven temperature was programmed to initiate at 50°C and held for 1.5 minutes before being raised to 300°C at a rate 40°C/minute and held for 3 minutes. Sample pre-treatment by modification of the QuEChERS method includes using a relatively large amount of inorganic salt, extraction volume and extraction cycle. The optimal conditions for processing a 400 uL urine sample were 160 mg magnesium sulphate, 40 mg sodium chloride, and 400 uL acetonitrile for organic solvent. According to the validation test, the detection limit for methamphetamine was 0.36 ug/mL; the quantitation limit was 1.09 ug/mL, and the calibration curve followed the regression line. y=1.0489x-3.7914, coefficient (r) was 0.9973. The recovery of the analyte spiked into urine at 5, 7 and 9 ug/mL on average was 100.5±2.33% for intraday dan 93.3±7.21% for interday. The precision was excellent, with an average coefficient of variation of 2.31%. The procedure was applied to four urine samples from drug users and the first abuser (25.51 ug/mL), the second abuser (15.05 ug/mL), the third abuser (17.72 ug/mL) and the last abuser (3.08 ug/mL) were all satisfactorily quantitated.","PeriodicalId":21644,"journal":{"name":"Science and Technology Indonesia","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-07-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Science and Technology Indonesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26554/sti.2023.8.3.451-460","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Pharmacology, Toxicology and Pharmaceutics","Score":null,"Total":0}
引用次数: 0

Abstract

This paper explains the development of a quick and easy gas chromatography (GC) approach to identify methamphetamine in urine. This research used gas chromatography with mass spectroscopy and a capillary column TG-5SILMS (5% phenyl methyl siloxane, 30 m x 0.32 x 25 m). The carrier gas flow rate was set at 1.0 mL/minute, the temperature inlet and detector had been set at 300°C, and the oven temperature was programmed to initiate at 50°C and held for 1.5 minutes before being raised to 300°C at a rate 40°C/minute and held for 3 minutes. Sample pre-treatment by modification of the QuEChERS method includes using a relatively large amount of inorganic salt, extraction volume and extraction cycle. The optimal conditions for processing a 400 uL urine sample were 160 mg magnesium sulphate, 40 mg sodium chloride, and 400 uL acetonitrile for organic solvent. According to the validation test, the detection limit for methamphetamine was 0.36 ug/mL; the quantitation limit was 1.09 ug/mL, and the calibration curve followed the regression line. y=1.0489x-3.7914, coefficient (r) was 0.9973. The recovery of the analyte spiked into urine at 5, 7 and 9 ug/mL on average was 100.5±2.33% for intraday dan 93.3±7.21% for interday. The precision was excellent, with an average coefficient of variation of 2.31%. The procedure was applied to four urine samples from drug users and the first abuser (25.51 ug/mL), the second abuser (15.05 ug/mL), the third abuser (17.72 ug/mL) and the last abuser (3.08 ug/mL) were all satisfactorily quantitated.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
小型化QuEChERS分析尿中甲基苯丙胺的GC/MS方法的建立与验证
本文介绍了一种快速简便的气相色谱法(GC)检测尿液中甲基苯丙胺的方法。本研究使用了气相色谱质谱和毛细管柱TG-5SILMS(5%苯基甲基硅氧烷,30m x 0.32 x 25m)。载气流速设定为1.0 mL/分钟,温度入口和检测器设定为300°C,烘箱温度设定为在50°C启动并保持1.5分钟,然后以40°C/分钟的速度升至300°C并保持3分钟。通过改进QuEChERS方法对样品进行预处理,包括使用相对大量的无机盐、提取体积和提取周期。处理400微升尿样的最佳条件是160毫克硫酸镁、40毫克氯化钠和400微升乙腈作为有机溶剂。根据验证试验,甲基苯丙胺的检测限为0.36微克/毫升;定量限为1.09ug/mL,校准曲线遵循回归线。y=1.0489x-3.7914,系数(r)为0.9973。以5、7和9微克/毫升的浓度掺入尿液的分析物的平均回收率为100.5±2.33%,日间为93.3±7.21%。该程序应用于吸毒者的四份尿液样本,第一次吸毒者(25.51微克/毫升)、第二次吸毒者、第三次吸毒者和最后一次吸毒者的尿液样本均能令人满意地定量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Science and Technology Indonesia
Science and Technology Indonesia Pharmacology, Toxicology and Pharmaceutics-Pharmacology, Toxicology and Pharmaceutics (miscellaneous)
CiteScore
1.80
自引率
0.00%
发文量
72
审稿时长
8 weeks
期刊最新文献
Modification of Indonesian Kaolinite-Based Silica Coarse (SC) for RNA Extraction Method of SARS-CoV-2 An Updated Water Masses Stratification of Indonesian Maritime Continent (IMC) Attributed to Normal and ENSO Conditions by Argo Float Anti-Inflammatory Activity and Phytochemical Profile from the Leaves of the Mangrove Sonneratia caseolaris (L.) Engl. for Future Drug Discovery Results on Toeplitz Determinants for Subclasses of Analytic Functions Associated to q-Derivative Operator LSTM-CNN Hybrid Model Performance Improvement with BioWordVec for Biomedical Report Big Data Classification
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1