Aminotransferase Activity Measurement on The Atellica® CH 930 and The Architect® ci4100

Soumia Nachate, Hind Zrikem, Fayrouz Debbagh, S. Chellak, A. Boukhira
{"title":"Aminotransferase Activity Measurement on The Atellica® CH 930 and The Architect® ci4100","authors":"Soumia Nachate, Hind Zrikem, Fayrouz Debbagh, S. Chellak, A. Boukhira","doi":"10.24018/ejbio.2023.4.4.472","DOIUrl":null,"url":null,"abstract":"\n\n\n\nThe Atellica® CH 930 is a new biochemistry analyzer recently introduced to the world market. This study aims to compare the Atellica® CH 930 analyzer to the Architect® ci4100 analyzer for measurement of serum aspartate (AST) and alanine (ALT) aminotransferase concentrations. A total of 112 sera were tested on the Architect® ci4100 and the Atellica® CH 930 analyzers for ALT and AST activities, and the results were compared using the paired Student's t-test, Pearson’s correlation analysis, Passing-Bablok regression analysis, and Bland–Altman plots. There was no significant difference between the means of the ALT and AST concentrations measured using the two instruments (p = 0.659 and p = 0.506, respectively). For ALT, the Passing-Bablok equation was Atellica=1.11 ×Architect -0.96, with a correlation coefficient (r) of 0.999. For AST, it was Atellica=1.08 ×Architect -0.50, with r = 0.998. According to Bland-Altman plots, the mean difference between both methods was 2.3 IU/L (4.3%) for ALT and 2.1 IU/L (5.8%) for AST, with 95.53% and 96.43% of points within the interval [0 ± 1.96 × SD], respectively. These findings demonstrated that the Atellica® CH 930 and Architect® ci4100 methods had an overall good agreement in aminotransferase measurement.\n\n\n\n\n ","PeriodicalId":72969,"journal":{"name":"European journal of biology and biotechnology","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European journal of biology and biotechnology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24018/ejbio.2023.4.4.472","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The Atellica® CH 930 is a new biochemistry analyzer recently introduced to the world market. This study aims to compare the Atellica® CH 930 analyzer to the Architect® ci4100 analyzer for measurement of serum aspartate (AST) and alanine (ALT) aminotransferase concentrations. A total of 112 sera were tested on the Architect® ci4100 and the Atellica® CH 930 analyzers for ALT and AST activities, and the results were compared using the paired Student's t-test, Pearson’s correlation analysis, Passing-Bablok regression analysis, and Bland–Altman plots. There was no significant difference between the means of the ALT and AST concentrations measured using the two instruments (p = 0.659 and p = 0.506, respectively). For ALT, the Passing-Bablok equation was Atellica=1.11 ×Architect -0.96, with a correlation coefficient (r) of 0.999. For AST, it was Atellica=1.08 ×Architect -0.50, with r = 0.998. According to Bland-Altman plots, the mean difference between both methods was 2.3 IU/L (4.3%) for ALT and 2.1 IU/L (5.8%) for AST, with 95.53% and 96.43% of points within the interval [0 ± 1.96 × SD], respectively. These findings demonstrated that the Atellica® CH 930 and Architect® ci4100 methods had an overall good agreement in aminotransferase measurement.  
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Atellica®CH 930和The Architect®ci4100上的氨基转移酶活性测量
Atellica®CH 930是最近引入世界市场的一种新型生物化学分析仪。本研究旨在将Atellica®CH 930分析仪与Architect®ci4100分析仪进行比较,以测量血清天冬氨酸(AST)和丙氨酸(ALT)转氨酶浓度。在Architect®ci4100和Atellica®CH 930分析仪上对总共112份血清进行ALT和AST活性测试,并使用配对Student t检验、Pearson相关分析、Passing Bablok回归分析和Bland–Altman图对结果进行比较。使用两种仪器测量的ALT和AST浓度的平均值之间没有显著差异(分别为p=0.659和p=0.506)。对于ALT,Passing Bablok方程为Atellica=1.11×Architect-0.96,相关系数(r)为0.999。AST为Atellica=1.08×Architect-0.50,r=0.998。根据Bland-Altman图,两种方法之间的ALT平均差异为2.3 IU/L(4.3%),AST平均差异为2.1 IU/L(5.8%),区间[0±1.96×SD]内的点分别为95.53%和96.43%。这些发现表明,Atellica®CH 930和Architect®ci4100方法在转氨酶测量方面总体一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparative Study of Jatropha curcas Accessions Control of Photoinhibition and Photoprotective Mechanisms in Senescing Leaves in a Semi-Arid Region Botswana Point-of-Care Molecular Testing with tinto rangTM: A Food Grade Safe Fluorophore for Colorimetric LAMP Assays at Low Resource Settings New Species of Preussia from Sedimentary Cost in Basrah Province, Iraq Sexual Dimorphism of Elastic Fibers in Prenatal Lung Mice Microbial Biotechnology: A Key Tool for Addressing Climate Change and Food Insecurity
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1