Rapid Determination of Bucinnazine in Blood by UPLC-MS/MS.

Zhang-Ming Gao, Jing-Yu Shi, Hao Zeng, Xue-Jun Zhang
{"title":"Rapid Determination of Bucinnazine in Blood by UPLC-MS/MS.","authors":"Zhang-Ming Gao,&nbsp;Jing-Yu Shi,&nbsp;Hao Zeng,&nbsp;Xue-Jun Zhang","doi":"10.12116/j.issn.1004-5619.2022.320702","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To establish a rapid method for the analysis of bucinnazine in blood by UPLC-MS/MS and to apply the method to the practical case.</p><p><strong>Methods: </strong>After the internal standard was added to blood, the protein was precipitated with 900 μL mixed solution (<i>V</i><sub>acetonitrile</sub>∶<i>V</i><sub>water</sub>=8∶2). After vortex and centrifugation, the protein was measured through 0.22 μm filter membrane. The separation was performed on C<sub>18</sub> chromatography column, with acetonitrile and 5 mmol/L ammonium acetate containing 0.1% formic acid aqueous as mobile phase gradient elution at the flow rate of 0.4 mL/min. Multiple reaction monitoring scan was performed in electrospray positive ion mode, quantitative measurement was performed by internal standard method, and methodological verification was carried out.</p><p><strong>Results: </strong>The linear relationship of bucinnazine in blood was good in the range of 0.5-200 μg/L, the correlation coefficient (<i>r</i>) was 0.999 7, the limit of detection was 0.1 μg/L, the limit of quantitation was 0.5 μg/L, and the recovery was 78.3%-83.8% at 1, 10 and 100 μg/L mass concentration levels. The matrix effect was 69.4%-73.8%, the intra-day precision was 1.9%-2.8%, and the inter-day precision was 2.8%-3.2%, the accuracy was 3.1%-3.5%. The stability test results of 1 and 100 μg/L mass concentrations at -25 ℃ showed that the accuracy (bias) of 10 d was less than 4.5%.</p><p><strong>Conclusions: </strong>This method has the advantages of simple pre-treatment process, fast sample processing speed, high sensitivity of instrument analysis, good stability of content determination and reliable identification results, and can meet the needs of case identification.</p>","PeriodicalId":12317,"journal":{"name":"法医学杂志","volume":"39 4","pages":"388-392"},"PeriodicalIF":0.0000,"publicationDate":"2023-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"法医学杂志","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12116/j.issn.1004-5619.2022.320702","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To establish a rapid method for the analysis of bucinnazine in blood by UPLC-MS/MS and to apply the method to the practical case.

Methods: After the internal standard was added to blood, the protein was precipitated with 900 μL mixed solution (VacetonitrileVwater=8∶2). After vortex and centrifugation, the protein was measured through 0.22 μm filter membrane. The separation was performed on C18 chromatography column, with acetonitrile and 5 mmol/L ammonium acetate containing 0.1% formic acid aqueous as mobile phase gradient elution at the flow rate of 0.4 mL/min. Multiple reaction monitoring scan was performed in electrospray positive ion mode, quantitative measurement was performed by internal standard method, and methodological verification was carried out.

Results: The linear relationship of bucinnazine in blood was good in the range of 0.5-200 μg/L, the correlation coefficient (r) was 0.999 7, the limit of detection was 0.1 μg/L, the limit of quantitation was 0.5 μg/L, and the recovery was 78.3%-83.8% at 1, 10 and 100 μg/L mass concentration levels. The matrix effect was 69.4%-73.8%, the intra-day precision was 1.9%-2.8%, and the inter-day precision was 2.8%-3.2%, the accuracy was 3.1%-3.5%. The stability test results of 1 and 100 μg/L mass concentrations at -25 ℃ showed that the accuracy (bias) of 10 d was less than 4.5%.

Conclusions: This method has the advantages of simple pre-treatment process, fast sample processing speed, high sensitivity of instrument analysis, good stability of content determination and reliable identification results, and can meet the needs of case identification.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
UPLC-MS/MS法快速测定血液中丁嗪的含量。
目的:建立UPLC-MS/MS快速测定血液中丁丙嗪含量的方法,并将该方法应用于实际。方法:将内标物加入血液后,用900μL乙腈∶水=8∶2的混合溶液沉淀蛋白质。涡旋和离心后,通过0.22μm的滤膜测量蛋白质。分离在C18色谱柱上进行,以乙腈和含有0.1%甲酸水溶液的5mmol/L乙酸铵作为流动相梯度洗脱,流速为0.4mL/min。采用电喷雾正离子模式进行多反应监测扫描,采用内标法进行定量测量,并进行方法学验证。结果:在1、10和100μg/L质量浓度范围内,血中丁桂嗪的线性关系良好,相关系数(r)为0.9997,检测限为0.1μg/L,定量限为0.5μg/L,回收率为78.3%-83.8%。基质效应为69.4%-73.8%,日内精密度为1.9%-2.8%,日间精密度为2.8%-3.2%,准确度为3.1%-3.5%。1和100μg/L质量浓度在-25℃下的稳定性测试结果表明,10d的准确度(偏差)小于4.5%。结论:该方法具有预处理过程简单、样品处理速度快、,仪器分析灵敏度高,含量测定稳定性好,鉴定结果可靠,能满足病例鉴定的需要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
法医学杂志
法医学杂志 Medicine-Pathology and Forensic Medicine
CiteScore
1.50
自引率
0.00%
发文量
0
期刊介绍:
期刊最新文献
Advances in the Study of Cerebrocardiac Syndrome and Its Forensic Significance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1