Determination of selenium in cereal and biofortified samples by ICP-OES using an alcohol-based deep eutectic solvent in digestion procedure

IF 5.2 Q1 CHEMISTRY, ANALYTICAL Advances in Sample Preparation Pub Date : 2023-10-01 DOI:10.1016/j.sampre.2023.100092
Masixole Sihlahla , Anele Mpupa , Marcin Sojka , Agnieszka Saeid , Philiswa Nosizo Nomngongo
{"title":"Determination of selenium in cereal and biofortified samples by ICP-OES using an alcohol-based deep eutectic solvent in digestion procedure","authors":"Masixole Sihlahla ,&nbsp;Anele Mpupa ,&nbsp;Marcin Sojka ,&nbsp;Agnieszka Saeid ,&nbsp;Philiswa Nosizo Nomngongo","doi":"10.1016/j.sampre.2023.100092","DOIUrl":null,"url":null,"abstract":"<div><p>The application of deep eutectic solvents (DESs) as green solvents in analytical chemistry has attracted increasing attention. The present study presents a simple, eco-friendly, and cost-effective approach for the extraction of selenium (Se) in food samples. The extraction method utilised alcohol-based DES and inductively coupled plasma optical emission spectrometry (ICP-OES) to determine total Se. Factors affecting the extraction procedure were optimised using the design of experiments. Using the optimal conditions, the limits of detection (LOD) and quantification (LOQ) and linearity of the developed method were 0.0011 µg Se/g, 0.0037 µg Se/g and 0.004–0.20 µg Se/g, respectively. The precision expressed as relative standard deviations (RSDs) was less than 10 %. The accuracy of the method was investigated using certified reference materials (IRMM 804 Rice Flour and NIST SRM 1567b wheat flour), and the results were in close agreement with the certified values (0.038 µg/g and 1.14 µg/g) with percentage recoveries ranging from 89.5 to 106 %. The interday ( %RSD) and Intraday ( %RSD) were 2.8–5.4 % and 4.3–5.9 %, respectively. The greenness of the method was assessed using NEMI, AES, and AGREE metrics tools. When comparing all these tools, they all qualified the proposed method as green.</p></div>","PeriodicalId":100052,"journal":{"name":"Advances in Sample Preparation","volume":"8 ","pages":"Article 100092"},"PeriodicalIF":5.2000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Sample Preparation","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772582023000426","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The application of deep eutectic solvents (DESs) as green solvents in analytical chemistry has attracted increasing attention. The present study presents a simple, eco-friendly, and cost-effective approach for the extraction of selenium (Se) in food samples. The extraction method utilised alcohol-based DES and inductively coupled plasma optical emission spectrometry (ICP-OES) to determine total Se. Factors affecting the extraction procedure were optimised using the design of experiments. Using the optimal conditions, the limits of detection (LOD) and quantification (LOQ) and linearity of the developed method were 0.0011 µg Se/g, 0.0037 µg Se/g and 0.004–0.20 µg Se/g, respectively. The precision expressed as relative standard deviations (RSDs) was less than 10 %. The accuracy of the method was investigated using certified reference materials (IRMM 804 Rice Flour and NIST SRM 1567b wheat flour), and the results were in close agreement with the certified values (0.038 µg/g and 1.14 µg/g) with percentage recoveries ranging from 89.5 to 106 %. The interday ( %RSD) and Intraday ( %RSD) were 2.8–5.4 % and 4.3–5.9 %, respectively. The greenness of the method was assessed using NEMI, AES, and AGREE metrics tools. When comparing all these tools, they all qualified the proposed method as green.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用醇基深度共晶溶剂消解ICP-OES测定谷物和生物强化样品中的硒
深共晶溶剂作为绿色溶剂在分析化学中的应用越来越受到关注。本研究提出了一种简单、环保、经济高效的食品样品硒提取方法。提取方法利用醇基DES和电感耦合等离子体发射光谱法(ICP-OES)测定总硒。通过实验设计优化了影响提取过程的因素。使用最佳条件,所开发方法的检测限(LOD)、定量限(LOQ)和线性度分别为0.0011µg Se/g、0.0037µg Seg/g和0.004–0.20µg Se/g。用相对标准偏差表示的精密度小于10%。使用经认证的参考材料(IRMM 804米粉和NIST SRM 1567b小麦粉)对该方法的准确性进行了研究,结果与认证值(0.038µg/g和1.14µg/g)非常一致,回收率在89.5%至106%之间。日内(%RSD)和日内(%RSD)分别为2.8–5.4%和4.3–5.9%。使用NEMI、AES和AGREE度量工具评估该方法的绿色性。在比较所有这些工具时,他们都认为所提出的方法是绿色的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.50
自引率
0.00%
发文量
0
期刊最新文献
Determination of steroid hormones in sea urchins by microwave-assisted extraction and ultrahigh-performance liquid chromatography tandem mass spectrometry Extraction of synthetic cathinones from biological samples: A systematic review Microextraction by packed sorbent: Introducing a novel hybrid silica-based chitosan-graphene oxide biosorbent for the evaluation of pesticides and antibiotics in food matrices One step derivatization and switchable hydrophilicity solvent-based microextraction for the determination of adamantane analogues in human urine by HPLC-FLD Recent advances in the application of MOFs and COFs composites for sample preparation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1