Quantitative estimation of tritium amount in surface layer and bulk of tungsten sample using BIXS

Yang Yang, Zhilin Chen, Po Huang, Shenghan Cheng, Wenxiang Jiang
{"title":"Quantitative estimation of tritium amount in surface layer and bulk of tungsten sample using BIXS","authors":"Yang Yang,&nbsp;Zhilin Chen,&nbsp;Po Huang,&nbsp;Shenghan Cheng,&nbsp;Wenxiang Jiang","doi":"10.1016/j.nucana.2023.100062","DOIUrl":null,"url":null,"abstract":"<div><p>Estimation of both the surface tritium and tritium in bulk in key materials of fusion reactors is of great importance for tritium safety and the management of tritium-contaminated material. For the further quantitative analysis of tritium in solids, the elaborate BIXS spectra were calculated based on Monte Carlo simulation. Four types of tritium depth profile were considered to evaluate the quantitative estimation method. It is found that the attenuation of X-rays in tungsten depends on both the energy of X-rays and the depth of X-rays. The evaluation of tritium amount in surface layer indicated that the intensity of Ar(Kα) peak could be used to evaluate the surface tritium within 400 nm from the surface in most cases and the deviations were less than 9% in the calculation. The intensity of both W(Lα) X-rays and the high energy X-rays can be employed to roughly estimate the total tritium amount. For linearly decreasing and exponentially decreasing distribution, the maximum calculation deviations were 24.9% and 28.8%, respectively. While for Gaussian distribution, the maximum deviations were 146% and 53%, respectively. And it can also be used for tritium estimation in other materials.</p></div>","PeriodicalId":100965,"journal":{"name":"Nuclear Analysis","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Analysis","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2773183923000162","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Estimation of both the surface tritium and tritium in bulk in key materials of fusion reactors is of great importance for tritium safety and the management of tritium-contaminated material. For the further quantitative analysis of tritium in solids, the elaborate BIXS spectra were calculated based on Monte Carlo simulation. Four types of tritium depth profile were considered to evaluate the quantitative estimation method. It is found that the attenuation of X-rays in tungsten depends on both the energy of X-rays and the depth of X-rays. The evaluation of tritium amount in surface layer indicated that the intensity of Ar(Kα) peak could be used to evaluate the surface tritium within 400 nm from the surface in most cases and the deviations were less than 9% in the calculation. The intensity of both W(Lα) X-rays and the high energy X-rays can be employed to roughly estimate the total tritium amount. For linearly decreasing and exponentially decreasing distribution, the maximum calculation deviations were 24.9% and 28.8%, respectively. While for Gaussian distribution, the maximum deviations were 146% and 53%, respectively. And it can also be used for tritium estimation in other materials.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用BIXS定量估算钨样品表层和大块中的氚含量
聚变堆关键材料中表面氚和散装氚的估算对氚安全和氚污染材料的管理具有重要意义。为了进一步定量分析固体中的氚,基于蒙特卡罗模拟计算了详细的BIXS光谱。考虑了四种类型的氚深度剖面来评价定量估算方法。研究发现,X射线在钨中的衰减取决于X射线的能量和深度。对表层氚含量的评估表明,在大多数情况下,Ar(Kα)峰的强度可以用来评估距离表面400nm以内的表面氚,计算中的偏差小于9%。W(Lα)X射线和高能X射线的强度可以用来粗略估计氚的总量。对于线性递减和指数递减分布,最大计算偏差分别为24.9%和28.8%。而对于高斯分布,最大偏差分别为146%和53%。它也可用于其他材料中氚的估算。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.70
自引率
0.00%
发文量
0
期刊最新文献
A comparative analysis of the NaI detector response function using GAMOS and FLUKA Monte Carlo simulations Coulomb interaction dependence of optimal energy to synthesize superheavy elements Structural insights into soft matter materials via spin echo small angle neutron scattering and small angle neutron scattering Major and trace elements determination in organic and conventional Moroccan vegetables using the k0-standardisation method of neutron activation analysis Gold nanoparticle effect on dose and DNA damage enhancement in the vicinity of gold nanoparticles
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1