MIP-based electrochemical sensor for highly selective and sensitive determination of entacapone from the triple mixture in tablet dosage form

Fatma Budak , Ahmet Cetinkaya , S. Irem Kaya , Sibel A. Ozkan
{"title":"MIP-based electrochemical sensor for highly selective and sensitive determination of entacapone from the triple mixture in tablet dosage form","authors":"Fatma Budak ,&nbsp;Ahmet Cetinkaya ,&nbsp;S. Irem Kaya ,&nbsp;Sibel A. Ozkan","doi":"10.1016/j.jpbao.2023.100005","DOIUrl":null,"url":null,"abstract":"<div><p>The aim of this study is to develop a molecularly imprinted polymer (MIP) sensor via photopolymerization for selective and sensitive analysis of entacapone (ENT), a catecholamine-o-methyl transferase (COMT) inhibitor. ENT is used for Parkinson’s disease treatment with levodopa (LEV) and carbidopa (CAR), and it is available in a triple combination tablet dosage form. For the MIP-based electrochemical sensor (4-AP@MIP/GCE) design, 4-aminophenol (4-AP) was selected as the functional monomer. Surface characterization of the 4-AP@MIP/GCE sensor was performed by scanning electron microscopy, electrochemical characterization by CV, and electrochemical impedance spectroscopy (EIS). The linear concentration range was between 1.0 pM and 10.0 pM under optimum conditions for ENT determination. The limit of detection (LOD) of 0.24 pM and the limit of quantification (LOQ) of 0.80 pM were calculated for ENT analysis using 4-AP@MIP/GCE. The accuracy was proven by performing a recovery study on the tablet sample that contains ENT, LEV, and CAR, and the recovery was found to be 99.32%. The selectivity of the 4-AP@MIP/GCE sensor for ENT has been proven by interference studies on LEV, CAR, and their binary mixtures. Looking at the results of the study, it has been proven that the 4-AP@MIP/GCE sensor is a highly selective, sensitive, and specific quantitative option for the analysis of ENT.</p></div>","PeriodicalId":100822,"journal":{"name":"Journal of Pharmaceutical and Biomedical Analysis Open","volume":"1 ","pages":"Article 100005"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Pharmaceutical and Biomedical Analysis Open","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2949771X23000051","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The aim of this study is to develop a molecularly imprinted polymer (MIP) sensor via photopolymerization for selective and sensitive analysis of entacapone (ENT), a catecholamine-o-methyl transferase (COMT) inhibitor. ENT is used for Parkinson’s disease treatment with levodopa (LEV) and carbidopa (CAR), and it is available in a triple combination tablet dosage form. For the MIP-based electrochemical sensor (4-AP@MIP/GCE) design, 4-aminophenol (4-AP) was selected as the functional monomer. Surface characterization of the 4-AP@MIP/GCE sensor was performed by scanning electron microscopy, electrochemical characterization by CV, and electrochemical impedance spectroscopy (EIS). The linear concentration range was between 1.0 pM and 10.0 pM under optimum conditions for ENT determination. The limit of detection (LOD) of 0.24 pM and the limit of quantification (LOQ) of 0.80 pM were calculated for ENT analysis using 4-AP@MIP/GCE. The accuracy was proven by performing a recovery study on the tablet sample that contains ENT, LEV, and CAR, and the recovery was found to be 99.32%. The selectivity of the 4-AP@MIP/GCE sensor for ENT has been proven by interference studies on LEV, CAR, and their binary mixtures. Looking at the results of the study, it has been proven that the 4-AP@MIP/GCE sensor is a highly selective, sensitive, and specific quantitative option for the analysis of ENT.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于mip的电化学传感器高选择性、高灵敏度测定恩他卡彭片剂剂型
本研究的目的是通过光聚合开发一种分子印迹聚合物(MIP)传感器,用于儿茶酚胺-邻甲基转移酶(COMT)抑制剂五卡彭(ENT)的选择性和灵敏分析。耳鼻喉科用于左旋多巴(LEV)和卡比多巴(CAR)治疗帕金森病,有三种组合片剂剂型。用于基于MIP的电化学传感器(4-AP@MIP/GCE)设计,选择4-氨基苯酚(4-AP)为功能单体。表面特征4-AP@MIP/通过扫描电子显微镜、CV电化学表征和电化学阻抗谱(EIS)对GCE传感器进行了表征。在ENT测定的最佳条件下,线性浓度范围在1.0pM和10.0pM之间。耳鼻喉科分析的检测限(LOD)为0.24 pM,定量限(LOQ)为0.80 pM4-AP@MIP/GCE。通过对含有ENT、LEV和CAR的片剂样品进行回收率研究证明了其准确性,回收率为99.32%4-AP@MIP/通过对LEV、CAR及其二元混合物的干扰研究,已经证明了用于耳鼻喉科的GCE传感器。从研究结果来看4-AP@MIP/GCE传感器是一种用于耳鼻喉科分析的高度选择性、敏感性和特异性的定量选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development and application of an LC-MS/MS method for the determination of 15 antipsychotic and 15 psychotic drugs and metabolites in plasma Quantitative analysis of D/L-serine and D/L-proline in serum by isotope-coded derivatization using an original chiral resolution labeling reagent Investigation of the metabolic role of d-amino acid aminotransferase in Arabidopsis thaliana using a column-switching two-dimensional high-performance liquid chromatography system Microsampling for antidepressant drug analysis: Current state and perspectives A simple approach for amperometric determination of pyridoxine and caffeine in pre-workout supplements using batch injection analysis with boron-doped diamond electrode
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1