Resilience-Oriented Valuation for Energy Storage Amidst Extreme Events

Youzhen Wu;Jianxiao Wang;Yiyang Song;Yunyun Xie
{"title":"Resilience-Oriented Valuation for Energy Storage Amidst Extreme Events","authors":"Youzhen Wu;Jianxiao Wang;Yiyang Song;Yunyun Xie","doi":"10.23919/CJEE.2023.000031","DOIUrl":null,"url":null,"abstract":"In power grids, the frequency is increasing of extreme accidents which have a low probability but high risk such as natural disasters and deliberate attacks. This has sparked discussions on the resilience of power grids. Energy-storage systems (ESSs) are critical for enhancing the resilience of power grids. ESSs, with their mechanism of flexible charging and discharging, adjust energy usage as needed during disasters, thereby mitigating the impact on the grid and enhancing security and resilience. This, in turn, ensures the power system's stable operation. Currently, there is limited systematic research quantifying the economic value of energy storage in resilience scenarios. Therefore, a model and methodology were proposed to quantify the value of energy storage systems for enhancing grid resilience during extreme events. A two-stage stochastic optimization mathematical model was developed. The first stage involves pre-deployment based on day-ahead expectations, and the second stage involves simulating potential failure scenarios through real-time scheduling. Considering the temporal dimension, the energy storage systems with flexible regulation capabilities was used as emergency power sources to reduce occurrences of load-shedding. Here, a novel index was proposed that quantifies the resilience value of energy storage as the economic value of energy storage per unit of capacity, as reflected in the emergency dispatch model. This index helps determine the balance between the energy storage investment cost and resilience value. Finally, an IEEE-30 node transmission system was used to verify the feasibility and effectiveness of the proposed method. The findings revealed a significant improvement in the resilience value, with a 23.49% increase observed when energy storage systems were implemented compared to the scenario without energy storage systems. The optimal capacity configurations for the flywheel, lithium-ion batteries, and pumped hydro storage were 10 MW, 11 MW, and 12 MW, respectively, highlight their potential to maximize value in experimental system.","PeriodicalId":36428,"journal":{"name":"Chinese Journal of Electrical Engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/iel7/7873788/10272329/10272567.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chinese Journal of Electrical Engineering","FirstCategoryId":"1087","ListUrlMain":"https://ieeexplore.ieee.org/document/10272567/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

Abstract

In power grids, the frequency is increasing of extreme accidents which have a low probability but high risk such as natural disasters and deliberate attacks. This has sparked discussions on the resilience of power grids. Energy-storage systems (ESSs) are critical for enhancing the resilience of power grids. ESSs, with their mechanism of flexible charging and discharging, adjust energy usage as needed during disasters, thereby mitigating the impact on the grid and enhancing security and resilience. This, in turn, ensures the power system's stable operation. Currently, there is limited systematic research quantifying the economic value of energy storage in resilience scenarios. Therefore, a model and methodology were proposed to quantify the value of energy storage systems for enhancing grid resilience during extreme events. A two-stage stochastic optimization mathematical model was developed. The first stage involves pre-deployment based on day-ahead expectations, and the second stage involves simulating potential failure scenarios through real-time scheduling. Considering the temporal dimension, the energy storage systems with flexible regulation capabilities was used as emergency power sources to reduce occurrences of load-shedding. Here, a novel index was proposed that quantifies the resilience value of energy storage as the economic value of energy storage per unit of capacity, as reflected in the emergency dispatch model. This index helps determine the balance between the energy storage investment cost and resilience value. Finally, an IEEE-30 node transmission system was used to verify the feasibility and effectiveness of the proposed method. The findings revealed a significant improvement in the resilience value, with a 23.49% increase observed when energy storage systems were implemented compared to the scenario without energy storage systems. The optimal capacity configurations for the flywheel, lithium-ion batteries, and pumped hydro storage were 10 MW, 11 MW, and 12 MW, respectively, highlight their potential to maximize value in experimental system.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
极端事件下面向弹性的储能评估
在电网中,自然灾害和蓄意袭击等概率较低但风险较高的极端事故日益频繁。这引发了关于电网弹性的讨论。储能系统对于提高电网的弹性至关重要。ESS具有灵活的充电和放电机制,可在灾害期间根据需要调整能源使用,从而减轻对电网的影响,增强安全性和弹性。这反过来又确保了电力系统的稳定运行。目前,量化弹性情景下储能的经济价值的系统研究有限。因此,提出了一种模型和方法来量化储能系统在极端事件期间增强电网弹性的价值。建立了两阶段随机优化数学模型。第一阶段涉及基于日前预期的预部署,第二阶段涉及通过实时调度模拟潜在故障场景。考虑到时间维度,具有灵活调节能力的储能系统被用作应急电源,以减少甩负荷的发生。在此,提出了一个新的指标,将储能的弹性值量化为单位容量储能的经济值,如应急调度模型中所反映的那样。该指数有助于确定储能投资成本和弹性价值之间的平衡。最后,以IEEE-30节点传输系统为例,验证了该方法的可行性和有效性。研究结果显示,弹性值显著提高,与没有储能系统的情况相比,实施储能系统时观察到的弹性值增加了23.49%。飞轮、锂离子电池和抽水蓄能器的最佳容量配置分别为10MW、11MW和12MW,突出了它们在实验系统中实现价值最大化的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Chinese Journal of Electrical Engineering
Chinese Journal of Electrical Engineering Energy-Energy Engineering and Power Technology
CiteScore
7.80
自引率
0.00%
发文量
621
审稿时长
12 weeks
期刊最新文献
Contents Front Cover Hybrid Modulation Strategy with Voltage Balancing Control for Four-Level Neutral-Point Clamped Converters Design-Oriented Transient Stability Assessment for Droop-Controlled Converter Considering Grid Voltage Phase-Angle Jump Dynamic Reconstruction of Total-Cross-Tied Photovoltaic Array Based on Arrays Using an Improved Dung Beetle Algorithm
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1