Quantification of Flow Rates and Flow Volumes in Valve Regurgitation Using 3-D High Frame-Rate Ultrasound

Stefano Fiorentini;Erik Andreas Rye Berg;Hans Torp;Svend Aakhus;Jørgen Avdal
{"title":"Quantification of Flow Rates and Flow Volumes in Valve Regurgitation Using 3-D High Frame-Rate Ultrasound","authors":"Stefano Fiorentini;Erik Andreas Rye Berg;Hans Torp;Svend Aakhus;Jørgen Avdal","doi":"10.1109/OJUFFC.2023.3259941","DOIUrl":null,"url":null,"abstract":"Valve regurgitation is a cardiac condition caused by the incomplete closure of a cardiac valve. Untreated, this condition may result in cardiac failure. Regular monitoring of this condition is essential in guiding the decision process for surgical intervention. Current guidelines recommend a multi-parametric assessment of valve regurgitation using echocardiography, which is both time consuming and heavily dependent on the experience of the examiner. Several methods have been proposed to provide quantitative markers to facilitate the assessment of valve regurgitation, most notably the Proximal Isovelocity Surface Area (PISA) method and methods based on the quantification of the total Regurgitant Volume (RVol) from the power of backscattered blood signal. In this work, we propose a framework based on trans-thoracic 3-D high frame-rate acquisitions for the simultaneous estimation of the jet cross-sectional area and jet velocity directly at the jet core, which are then combined to estimate the instantaneous flow rate and RVol patients with aortic or mitral insufficiency. We compare two methods for the segmentation of the jet cross-sectional area from the power Doppler signal. Validation on simulated data indicates good segmentation accuracy for the best method (<inline-formula> <tex-math notation=\"LaTeX\">$\\beta $ </tex-math></inline-formula> = 0.97, <inline-formula> <tex-math notation=\"LaTeX\">${R}^{{2}}$ </tex-math></inline-formula> = 0.91). Validation on recordings from a flow phantom shows good agreement (<inline-formula> <tex-math notation=\"LaTeX\">$\\beta $ </tex-math></inline-formula> = 1.2, <inline-formula> <tex-math notation=\"LaTeX\">${R}^{{2}}$ </tex-math></inline-formula> = 0.88) with an external flow rate meter. Clinical feasibility of the method is also shown in a patient with mitral regurgitation.","PeriodicalId":73301,"journal":{"name":"IEEE open journal of ultrasonics, ferroelectrics, and frequency control","volume":"3 ","pages":"29-40"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/iel7/9292640/10031625/10077387.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE open journal of ultrasonics, ferroelectrics, and frequency control","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10077387/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Valve regurgitation is a cardiac condition caused by the incomplete closure of a cardiac valve. Untreated, this condition may result in cardiac failure. Regular monitoring of this condition is essential in guiding the decision process for surgical intervention. Current guidelines recommend a multi-parametric assessment of valve regurgitation using echocardiography, which is both time consuming and heavily dependent on the experience of the examiner. Several methods have been proposed to provide quantitative markers to facilitate the assessment of valve regurgitation, most notably the Proximal Isovelocity Surface Area (PISA) method and methods based on the quantification of the total Regurgitant Volume (RVol) from the power of backscattered blood signal. In this work, we propose a framework based on trans-thoracic 3-D high frame-rate acquisitions for the simultaneous estimation of the jet cross-sectional area and jet velocity directly at the jet core, which are then combined to estimate the instantaneous flow rate and RVol patients with aortic or mitral insufficiency. We compare two methods for the segmentation of the jet cross-sectional area from the power Doppler signal. Validation on simulated data indicates good segmentation accuracy for the best method ( $\beta $ = 0.97, ${R}^{{2}}$ = 0.91). Validation on recordings from a flow phantom shows good agreement ( $\beta $ = 1.2, ${R}^{{2}}$ = 0.88) with an external flow rate meter. Clinical feasibility of the method is also shown in a patient with mitral regurgitation.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用三维高帧率超声定量测量瓣膜返流的流量和流量
瓣膜反流是由心脏瓣膜关闭不完全引起的一种心脏疾病。如果不治疗,这种情况可能会导致心力衰竭。定期监测这种情况对于指导手术干预的决策过程至关重要。目前的指南建议使用超声心动图对瓣膜返流进行多参数评估,这既耗时又严重依赖于检查者的经验。已经提出了几种方法来提供定量标记以促进瓣膜反流的评估,最值得注意的是近端等流速表面积(PISA)方法和基于反向散射血液信号功率的总反流体积(RVol)量化的方法。在这项工作中,我们提出了一个基于经胸三维高帧率采集的框架,用于同时估计直接在射流核心处的射流截面积和射流速度,然后将其结合起来估计主动脉或二尖瓣功能不全患者的瞬时流速和RVol。我们比较了两种从功率多普勒信号中分割射流截面积的方法。仿真数据验证表明,最佳分割方法的分割精度较好($\beta $ = 0.97, ${R}^{{2}}$ = 0.91)。对流量幻象记录的验证显示,与外部流量计具有良好的一致性($\beta $ = 1.2, ${R}^{{2}}$ = 0.88)。该方法在二尖瓣反流患者中也显示了临床可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Preliminary Demonstration of Pulse-Echo Imaging With a Long Monolithic Flexible CMUT Array The 3D Estimation of Mechanical Wave Velocities in the Heart: Methods and Insights Direct Digital Simultaneous Phase-Amplitude Noise and Allan Deviation Measurement System Rochelle Salt Revisited for Eco-Designed Ultrasonic Transducers 3-D Object Reconstruction From Outdoor Ultrasonic Image and Variation Autoencoder
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1