Accuracy of Sonographic Airway Parameters in Difficult Laryngoscopy Prediction: A Prospective Observational Cohort Study from Central India.

S K Parameshwar, Sunaina Tejpal Karna, Vaishali Waindeskar, Harish Kumar, Pooja Singh, Saurabh Saigal
{"title":"Accuracy of Sonographic Airway Parameters in Difficult Laryngoscopy Prediction: A Prospective Observational Cohort Study from Central India.","authors":"S K Parameshwar,&nbsp;Sunaina Tejpal Karna,&nbsp;Vaishali Waindeskar,&nbsp;Harish Kumar,&nbsp;Pooja Singh,&nbsp;Saurabh Saigal","doi":"10.4274/TJAR.2023.231217","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Though airway ultrasonography (USG) is used to assess difficult laryngoscopy (DL), there is still ambiguity about approach followed and parameters assessed. There is need of a simple, stepwise sonographic assessment with clearly defined parameters for DL prediction. The primary objective of this study was to find diagnostic accuracy of sonographic parameters measured by a stepwise Airway-USG in DL prediction (DLP).</p><p><strong>Methods: </strong>This prospective, observational cohort study was done in 217 elective surgical adult patients administered general anaesthesia with tracheal intubation using conventional laryngoscopy from 1<sup>st</sup> May 2019 to 31<sup>st</sup> July 2020, after ethical approval. A sagittal Airway-USG was done using 2-6 Hz transducer in three steps specifying probe placement and head position. Demographic, clinical and Airway-USG measurements were noted. Correlation of the clinical/sonographic parameters was made with Cormack-Lehane score on DL. After receiver operating characteristic curve plotting, the sensitivity, specificity, positive predictive value, negative predictive value (NPV) of DL was calculated for each parameter using open-epi software.</p><p><strong>Results: </strong>DL was observed in 19/217 patients. Airway-USG parameters of skin to epiglottis distance >2.45 cm, hyomental distance with head extension <5.13 cm, head neutral <4.5 cm, their ratio <1.18, maximum tongue thickness >3.93 cm and maximum skin to tongue distance >5.45 cm were statistically significant in predicting DL. DLP score with presence of >3 positive parameters showed 98% specificity, 98% NPV and 96% diagnostic accuracy to predict DL.</p><p><strong>Conclusion: </strong>DLP score derived from Airway-USG may be used as a screening and diagnostic tool for DL.</p>","PeriodicalId":23353,"journal":{"name":"Turkish journal of anaesthesiology and reanimation","volume":"51 5","pages":"434-442"},"PeriodicalIF":0.6000,"publicationDate":"2023-10-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10606741/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkish journal of anaesthesiology and reanimation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4274/TJAR.2023.231217","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Though airway ultrasonography (USG) is used to assess difficult laryngoscopy (DL), there is still ambiguity about approach followed and parameters assessed. There is need of a simple, stepwise sonographic assessment with clearly defined parameters for DL prediction. The primary objective of this study was to find diagnostic accuracy of sonographic parameters measured by a stepwise Airway-USG in DL prediction (DLP).

Methods: This prospective, observational cohort study was done in 217 elective surgical adult patients administered general anaesthesia with tracheal intubation using conventional laryngoscopy from 1st May 2019 to 31st July 2020, after ethical approval. A sagittal Airway-USG was done using 2-6 Hz transducer in three steps specifying probe placement and head position. Demographic, clinical and Airway-USG measurements were noted. Correlation of the clinical/sonographic parameters was made with Cormack-Lehane score on DL. After receiver operating characteristic curve plotting, the sensitivity, specificity, positive predictive value, negative predictive value (NPV) of DL was calculated for each parameter using open-epi software.

Results: DL was observed in 19/217 patients. Airway-USG parameters of skin to epiglottis distance >2.45 cm, hyomental distance with head extension <5.13 cm, head neutral <4.5 cm, their ratio <1.18, maximum tongue thickness >3.93 cm and maximum skin to tongue distance >5.45 cm were statistically significant in predicting DL. DLP score with presence of >3 positive parameters showed 98% specificity, 98% NPV and 96% diagnostic accuracy to predict DL.

Conclusion: DLP score derived from Airway-USG may be used as a screening and diagnostic tool for DL.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
超声气道参数在困难喉镜预测中的准确性:一项来自印度中部的前瞻性观察队列研究。
目的:尽管气道超声检查(USG)用于评估困难喉镜检查(DL),但所采用的方法和评估的参数仍存在歧义。需要一种简单、逐步的超声评估,并明确定义DL预测的参数。本研究的主要目的是寻找通过逐步气道USG测量的DL预测(DLP)超声参数的诊断准确性。方法:这项前瞻性、观察性队列研究是在获得伦理批准后,于2019年5月1日至2020年7月31日对217名接受常规喉镜下气管插管全身麻醉的择期手术成年患者进行的。矢状气道USG使用2-6 Hz换能器分三步进行,指定探头位置和头部位置。注意到人口统计学、临床和气道USG测量。临床/超声参数与DL的Cormack-Lehane评分相关。在绘制受试者工作特性曲线后,使用开放epi软件计算每个参数的DL的敏感性、特异性、阳性预测值、阴性预测值(NPV)。结果:在217例患者中有19例出现DL。皮肤至会厌距离>2.45 cm、舌骨与头部延伸距离3.93 cm和最大皮肤至舌头距离>5.45 cm的气道USG参数在预测DL方面具有统计学意义。存在>3个阳性参数的DLP评分显示预测DL的特异性为98%,NPV为98%,诊断准确率为96%。结论:气道USG DLP评分可作为DL的筛查和诊断工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.10
自引率
0.00%
发文量
0
期刊最新文献
A Comparative Study of Magnesium Sulfate, Lignocaine, and Propofol for Attenuating Hemodynamic Response During Functional Endoscopic Sinus Surgery Under General Anaesthesia: A Prospective Randomized Trial. Anaesthesia Management of A Patient with Airway Obstruction Caused by Prosthetic Vascular Graft Invasion into the Tracheal Lumen. Bispectral Index Guidance Reduced Target Plasma Propofol Concentration During ERCP in Patients with Liver Cirrhosis. Dexmedetomidine Versus Fentanyl in Intraoperative Neuromuscular Monitoring Using A Propofol-based Total Intravenous Anaesthesia Regimen in Spine Surgeries. Implementation of ERAS Protocols: In Theory and Practice.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1