Harmonic-Invariant Scaling Method for Power Electronic Converters in Power Hardware-in-the-Loop Test Beds

IF 7.9 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC IEEE Open Journal of Industry Applications Pub Date : 2023-04-13 DOI:10.1109/OJIA.2023.3266882
Daniel Dos Santos Mota;Joseph Kiran Banda;Ayotunde Adekunle Adeyemo;Elisabetta Tedeschi
{"title":"Harmonic-Invariant Scaling Method for Power Electronic Converters in Power Hardware-in-the-Loop Test Beds","authors":"Daniel Dos Santos Mota;Joseph Kiran Banda;Ayotunde Adekunle Adeyemo;Elisabetta Tedeschi","doi":"10.1109/OJIA.2023.3266882","DOIUrl":null,"url":null,"abstract":"Power hardware-in-the-loop (PHIL) is an experimental technique that uses power amplifiers and real-time simulators for studying the dynamics of power electronic converters and electrical grids. Power hardware-in-the-loop (PHIL) tests provide the means for functional validation of advanced control algorithms without the burden of building high-power prototypes during early technology readiness levels. However, replicating the behavior of high-power systems with laboratory scaled-down converters (SDCs) can be complex. Inaccurate scaling of the SDCs coupled with an exclusive focus on instantaneous voltages and currents at the fundamental frequency can lead to PHIL results that are only partially relatable to the high-power systems under study. Test beds that fail to represent switching frequency harmonics cannot be used for studying harmonic penetration or loss characterization of large-scale converters. To tackle this issue, this article proposes a harmonic-invariant scaling method that exploits the volt-ampere rating of preexisting laboratory SDCs for more accurately replicating harmonic phenomena in a PHIL test bench. First, a theoretical analysis of the proposed method is presented and, subsequently, the method is validated with MATLAB simulations and experimental tests.","PeriodicalId":100629,"journal":{"name":"IEEE Open Journal of Industry Applications","volume":"4 ","pages":"139-148"},"PeriodicalIF":7.9000,"publicationDate":"2023-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/iel7/8782707/10008994/10101823.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Open Journal of Industry Applications","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10101823/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Power hardware-in-the-loop (PHIL) is an experimental technique that uses power amplifiers and real-time simulators for studying the dynamics of power electronic converters and electrical grids. Power hardware-in-the-loop (PHIL) tests provide the means for functional validation of advanced control algorithms without the burden of building high-power prototypes during early technology readiness levels. However, replicating the behavior of high-power systems with laboratory scaled-down converters (SDCs) can be complex. Inaccurate scaling of the SDCs coupled with an exclusive focus on instantaneous voltages and currents at the fundamental frequency can lead to PHIL results that are only partially relatable to the high-power systems under study. Test beds that fail to represent switching frequency harmonics cannot be used for studying harmonic penetration or loss characterization of large-scale converters. To tackle this issue, this article proposes a harmonic-invariant scaling method that exploits the volt-ampere rating of preexisting laboratory SDCs for more accurately replicating harmonic phenomena in a PHIL test bench. First, a theoretical analysis of the proposed method is presented and, subsequently, the method is validated with MATLAB simulations and experimental tests.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
电力半实物试验台中电力电子变换器的谐波不变标度方法
电力硬件在环(PHIL)是一种使用功率放大器和实时模拟器来研究电力电子转换器和电网动态的实验技术。功率硬件在环(PHIL)测试为高级控制算法的功能验证提供了手段,而无需在早期技术准备阶段构建高功率原型。然而,用实验室规模缩小的转换器(SDCs)复制高功率系统的行为可能很复杂。SDCs的不准确缩放,加上对基频下的瞬时电压和电流的专门关注,可能导致仅与所研究的高功率系统部分相关的PHIL结果。不能代表开关频率谐波的试验台不能用于研究大型变换器的谐波穿透或损耗特性。为了解决这个问题,本文提出了一种谐波不变缩放方法,该方法利用现有实验室SDC的额定伏安,在PHIL测试台上更准确地复制谐波现象。首先,对所提出的方法进行了理论分析,随后,通过MATLAB仿真和实验测试对该方法进行了验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
13.50
自引率
0.00%
发文量
0
期刊最新文献
IEEE Industry Applications Society Information Cooperative UAV Scheduling for Power Grid Deicing Using Fuzzy Learning and Evolutionary Optimization State-of-the-Art of CSR Design for Novel Applications Trend Front Cover IEEE Open Journal of Industry Applications Information for Authors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1