Manuel Parafita MS, MD, PhD (Dipl Ophthalmol) , Eva Yebra-Pimentel MS, PhD (OD) , Marı́a Jesús Giraldez (OD) , Javier González-Pérez (OD) , Marı́a Victoria P. érez-Martı́n MS, PhD , José González-Meijome (OD)
{"title":"Further information on the knowledge of topographical corneal thickness","authors":"Manuel Parafita MS, MD, PhD (Dipl Ophthalmol) , Eva Yebra-Pimentel MS, PhD (OD) , Marı́a Jesús Giraldez (OD) , Javier González-Pérez (OD) , Marı́a Victoria P. érez-Martı́n MS, PhD , José González-Meijome (OD)","doi":"10.1016/S0892-8967(00)00037-7","DOIUrl":null,"url":null,"abstract":"<div><p>Central and peripheral corneal thickness has been used increasingly to obtain information about physiologic and clinical conditions of the cornea. In this study, a new method based on ultrasonic pachometry for topographical corneal thickness measurement is described. Results suggest that the technique is reliable for clinical determination of global corneal thickness. Measurements taken by one observer on different sessions (intersession variation) and measurements taken by different observers (interobserver variation) are not significant different (<em>p</em><span> = 0.586 and 0.273, respectively). This new ultrasound topographical pachometric method can be considered a useful tool for determination of topographical corneal thickness. It has implications for the use of topographical ultrasonic pachometry in contact lenses research, refractive surgery, and management of different pathologic conditions.</span></p></div>","PeriodicalId":80286,"journal":{"name":"International contact lens clinic (New York, N.Y.)","volume":"26 5","pages":"Pages 128-137"},"PeriodicalIF":0.0000,"publicationDate":"1999-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0892-8967(00)00037-7","citationCount":"19","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International contact lens clinic (New York, N.Y.)","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0892896700000377","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 19
Abstract
Central and peripheral corneal thickness has been used increasingly to obtain information about physiologic and clinical conditions of the cornea. In this study, a new method based on ultrasonic pachometry for topographical corneal thickness measurement is described. Results suggest that the technique is reliable for clinical determination of global corneal thickness. Measurements taken by one observer on different sessions (intersession variation) and measurements taken by different observers (interobserver variation) are not significant different (p = 0.586 and 0.273, respectively). This new ultrasound topographical pachometric method can be considered a useful tool for determination of topographical corneal thickness. It has implications for the use of topographical ultrasonic pachometry in contact lenses research, refractive surgery, and management of different pathologic conditions.