Artificial Collapse of Blastocysts Before Vitrification: Mechanical vs. Laser Technique and Effect on Survival, Cell Number, and Cell Death in Early and Expanded Blastocysts
N. Desai, J. Szeptycki, M. Scott, F. Abdelhafez, J. Goldfarb
{"title":"Artificial Collapse of Blastocysts Before Vitrification: Mechanical vs. Laser Technique and Effect on Survival, Cell Number, and Cell Death in Early and Expanded Blastocysts","authors":"N. Desai, J. Szeptycki, M. Scott, F. Abdelhafez, J. Goldfarb","doi":"10.1089/CPT.2008.0007","DOIUrl":null,"url":null,"abstract":"The purpose of this study was to systematically examine blastocoelic fluid reduction prior to vitrification and its potential benefits. In addition, we compared artificial collapse (AC) by laser pulse to a mechanical method. Mouse and dicarded human blastocysts were used in this study. Blastocysts were collapsed using either a 10 ms pulse with a laser (LAC) or else mechanical puncture with a microneedle (MAC). Blastocysts were vitrified on cryoloops using a two-step ethylene glycol/dimethyl sulfoxide protocol. We examined the effects of AC on specific outcome parameters such as overall survival, reexpansion, cell proliferation, and DNA damage. Unlike others, we report overall high survival rates with expanded blastocysts even without fluid reduction. We did detect a significant increase in blastomeres showing signs of DNA damage in the control group (13%) in comparison to blastocysts AC prior to vitrification (LAC 3%, MAC 5%; p < 0.001). Control blastocysts exhibited a lower rate of reexpansion. Within 3 ...","PeriodicalId":51233,"journal":{"name":"Cell Preservation Technology","volume":"6 1","pages":"181-190"},"PeriodicalIF":0.0000,"publicationDate":"2008-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1089/CPT.2008.0007","citationCount":"29","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cell Preservation Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1089/CPT.2008.0007","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 29
Abstract
The purpose of this study was to systematically examine blastocoelic fluid reduction prior to vitrification and its potential benefits. In addition, we compared artificial collapse (AC) by laser pulse to a mechanical method. Mouse and dicarded human blastocysts were used in this study. Blastocysts were collapsed using either a 10 ms pulse with a laser (LAC) or else mechanical puncture with a microneedle (MAC). Blastocysts were vitrified on cryoloops using a two-step ethylene glycol/dimethyl sulfoxide protocol. We examined the effects of AC on specific outcome parameters such as overall survival, reexpansion, cell proliferation, and DNA damage. Unlike others, we report overall high survival rates with expanded blastocysts even without fluid reduction. We did detect a significant increase in blastomeres showing signs of DNA damage in the control group (13%) in comparison to blastocysts AC prior to vitrification (LAC 3%, MAC 5%; p < 0.001). Control blastocysts exhibited a lower rate of reexpansion. Within 3 ...