The effect of unilateral chest drainage for transpulmonary pressure during mechanical ventilation.

Pub Date : 2023-10-28 DOI:10.1186/s40981-023-00664-2
Takayuki Hasegawa, Yuzo Iseki, Atsuyuki Hosono, Satoki Inoue
{"title":"The effect of unilateral chest drainage for transpulmonary pressure during mechanical ventilation.","authors":"Takayuki Hasegawa,&nbsp;Yuzo Iseki,&nbsp;Atsuyuki Hosono,&nbsp;Satoki Inoue","doi":"10.1186/s40981-023-00664-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Chest tube drainage is usually performed through an underwater seal at a level of 10-20 cmH<sub>2</sub>O. Based on the definition of transpulmonary pressure, continuous chest drainage creates continuous negative pressure, decreasing pleural surface pressure and increasing transpulmonary pressure. We investigated how unilateral chest drainage could affect the tidal volume or driving pressure during mandatory mechanical ventilation.</p><p><strong>Methods: </strong>This study was an experimental study using a lung-thoracic model and anesthesia ventilator. Tidal volume was set to 300 mL with pressure-controlled ventilation or volume-controlled ventilation. Left tidal volume and right tidal volume were measured independently using respirometers with positive end-expiratory pressure (PEEP) levels of 0, 10, and 20 cmH<sub>2</sub>O. Simultaneously, left negative pressure of the chest drainage was changed to 0, 10, and 20 cmH<sub>2</sub>O.</p><p><strong>Results: </strong>In all conditions, a tidal volume of 300 mL was achieved. In both pressure-controlled ventilation and volume-controlled ventilation, the left tidal volume increased with the application of chest drainage at 10 cmH<sub>2</sub>O when the PEEP level was 0 cmH<sub>2</sub>O, but left tidal volume decreased with the application of chest drainage at 20 cmH<sub>2</sub>O. Furthermore, when PEEP was 10 cmH<sub>2</sub>O, the left tidal volume decreased in proportion to the pressure of thoracic drainage. The right tidal volumes changed inversely with their counterpart left tidal volumes.</p><p><strong>Conclusion: </strong>Unilateral chest drainage caused unbalanced ventilation of the left and right lungs regardless of pressure-controlled ventilation or volume-controlled ventilation.</p>","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10611669/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s40981-023-00664-2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Chest tube drainage is usually performed through an underwater seal at a level of 10-20 cmH2O. Based on the definition of transpulmonary pressure, continuous chest drainage creates continuous negative pressure, decreasing pleural surface pressure and increasing transpulmonary pressure. We investigated how unilateral chest drainage could affect the tidal volume or driving pressure during mandatory mechanical ventilation.

Methods: This study was an experimental study using a lung-thoracic model and anesthesia ventilator. Tidal volume was set to 300 mL with pressure-controlled ventilation or volume-controlled ventilation. Left tidal volume and right tidal volume were measured independently using respirometers with positive end-expiratory pressure (PEEP) levels of 0, 10, and 20 cmH2O. Simultaneously, left negative pressure of the chest drainage was changed to 0, 10, and 20 cmH2O.

Results: In all conditions, a tidal volume of 300 mL was achieved. In both pressure-controlled ventilation and volume-controlled ventilation, the left tidal volume increased with the application of chest drainage at 10 cmH2O when the PEEP level was 0 cmH2O, but left tidal volume decreased with the application of chest drainage at 20 cmH2O. Furthermore, when PEEP was 10 cmH2O, the left tidal volume decreased in proportion to the pressure of thoracic drainage. The right tidal volumes changed inversely with their counterpart left tidal volumes.

Conclusion: Unilateral chest drainage caused unbalanced ventilation of the left and right lungs regardless of pressure-controlled ventilation or volume-controlled ventilation.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
单侧胸腔引流对机械通气过程中经肺压力的影响。
简介:胸管引流通常通过10-20 cmH2O的水下密封进行。根据经肺压力的定义,持续胸腔引流产生持续负压,降低胸膜表面压力,增加经肺压力。我们研究了在强制机械通气期间,单侧胸腔引流如何影响潮气量或驱动压力。方法:采用胸肺模型和麻醉呼吸机进行实验研究。通过压力控制通气或体积控制通气将潮气量设置为300mL。使用呼气末正压(PEEP)水平为0、10和20 cmH2O的呼吸计独立测量左潮气量和右潮气量。同时,胸腔引流的左侧负压分别变为0、10和20 cmH2O。结果:在所有条件下,潮气量均达到300mL。在压力控制通气和容量控制通气中,当PEEP水平为0 cmH2O时,左侧潮气量随着10 cmH2O胸部引流的应用而增加,但左侧潮气量随20 cmH2O胸部排水的应用而减少。此外,当PEEP为10 cmH2O时,左侧潮气量与胸腔引流压力成比例下降。右侧潮气量与对应的左侧潮气量呈反比变化。结论:无论是压力控制通气还是容量控制通气,单侧胸腔引流均导致左右肺通气不平衡。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1