Review on Design Strategies of Energy Saving Office Building with Evaporative Cooling in Tropical Region

Rizvanda Ryan, Savero, G. N. Antaryama, B. Soemardiono, Kampus Its Sukolilo Gedung Arsitektur
{"title":"Review on Design Strategies of Energy Saving Office Building with Evaporative Cooling in Tropical Region","authors":"Rizvanda Ryan, Savero, G. N. Antaryama, B. Soemardiono, Kampus Its Sukolilo Gedung Arsitektur","doi":"10.12962/j20882033.v31i2.5607","DOIUrl":null,"url":null,"abstract":"This research reviews the theories and design of energy-saving office buildings that apply evaporative cooling concepts to inhibit solar heat and improve natural cooling. The limited land in urban areas forces the building orientation facing East-West to increase building heat gain in tropical regions. This research is interesting because evaporative cooling is rarely found in office building design, especially in tropical areas. The method used is literature searching (theory, journal, and president) related to the energy-saving building (passive design) and passive cooling with evaporative cooling techniques. A review of design strategies can be used as a reference for general criteria applied at the design stage of office building architectural design. As a limitation, questions are needed to find related theories such as (1) what are the factors of building heat control and the criteria required in designing energy-saving office building (2) how to apply evaporative cooling techniques to design the energy-saving office building. Solar heat is a key factor in building heat gain. So it must be noticed to control building heat to protect heat transfer into buildings. The results of the design energy saving office buildings in the tropical region have required the application of passive designs such as building orientation, building core placement, shading elements, cross ventilation, natural lighting, producing shape, and application of evaporative cooling with consideration of wind direction and hottest side due to solar radiation","PeriodicalId":14549,"journal":{"name":"IPTEK: The Journal for Technology and Science","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-08-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IPTEK: The Journal for Technology and Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12962/j20882033.v31i2.5607","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

This research reviews the theories and design of energy-saving office buildings that apply evaporative cooling concepts to inhibit solar heat and improve natural cooling. The limited land in urban areas forces the building orientation facing East-West to increase building heat gain in tropical regions. This research is interesting because evaporative cooling is rarely found in office building design, especially in tropical areas. The method used is literature searching (theory, journal, and president) related to the energy-saving building (passive design) and passive cooling with evaporative cooling techniques. A review of design strategies can be used as a reference for general criteria applied at the design stage of office building architectural design. As a limitation, questions are needed to find related theories such as (1) what are the factors of building heat control and the criteria required in designing energy-saving office building (2) how to apply evaporative cooling techniques to design the energy-saving office building. Solar heat is a key factor in building heat gain. So it must be noticed to control building heat to protect heat transfer into buildings. The results of the design energy saving office buildings in the tropical region have required the application of passive designs such as building orientation, building core placement, shading elements, cross ventilation, natural lighting, producing shape, and application of evaporative cooling with consideration of wind direction and hottest side due to solar radiation
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
热带地区蒸发冷却节能办公建筑设计策略综述
本研究回顾了运用蒸发冷却概念来抑制太阳热量和改善自然冷却的节能办公建筑的理论和设计。城市地区有限的土地迫使建筑朝向东西,以增加热带地区的建筑热增益。这项研究很有趣,因为蒸发冷却很少出现在办公楼设计中,特别是在热带地区。采用的方法是对节能建筑(被动式设计)和蒸发冷却技术被动式冷却相关的文献(理论、期刊、总裁)进行检索。通过对设计策略的回顾,可以为办公楼建筑设计阶段应用的一般准则提供参考。作为一种限制,需要寻找相关的理论问题,如(1)建筑热控制的因素是什么,设计节能办公建筑需要的标准是什么(2)如何应用蒸发冷却技术来设计节能办公建筑。太阳热量是建筑热增益的关键因素。因此,必须注意控制建筑热量,防止热量向建筑内传递。热带地区节能办公建筑的设计结果要求建筑朝向、建筑核心布置、遮阳元素、交叉通风、自然采光、生产造型等被动式设计的应用,以及考虑风向和太阳辐射最热侧的蒸发冷却应用
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
17
审稿时长
9 weeks
期刊最新文献
Deposition Silver Based Thin Film on Stainless Steel 316l as Antimicrobial Agent Using Electrophoretic Deposition Method Probabilistic Scheduling Based On Hybrid Bayesian Network–Program Evaluation Review Technique, Analysis of Level Team Effectiveness in The Implementation of Scrum Using Evidence-Based Management (Case Study: Company A as A Fintech Industry) Project Delay Risk Assessment User-Centered Design-Based Approach in Scheduling Management Application Design and Development
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1