Lighting and noise levels in compost dairy barns with natural and forced ventilation

Q2 Agricultural and Biological Sciences Agronomy research Pub Date : 2020-01-01 DOI:10.15159/AR.20.104
R. R. Andrade, I. Tinôco, F. A. Damasceno, M. Barbari, D. A. Valente, M. O. Vilela, C. F. Souza, L. Conti, G. Rossi
{"title":"Lighting and noise levels in compost dairy barns with natural and forced ventilation","authors":"R. R. Andrade, I. Tinôco, F. A. Damasceno, M. Barbari, D. A. Valente, M. O. Vilela, C. F. Souza, L. Conti, G. Rossi","doi":"10.15159/AR.20.104","DOIUrl":null,"url":null,"abstract":"The housing system, called compost barn, is attracting the interest of several farmers. It allows dairy cows to remain in free movement inside a shed without any containment partitions like those used in freestall barns. In Brazil the compost barns with open sides are very common, but recently some closed barns with climatic control systems have been implemented. The objective of this work was to evaluate and compare lighting and noise levels in an open compost barn with natural ventilation and in a closed compost barn with a climate control system. The latter one is based on tunnel ventilation: inlet of air trough evaporative cellulose panels and exit through fans placed on the opposite wall. Through analysis of the collected data it was observed that the sound pressure recorded inside both analysed buildings did not exceed the ranges of noise discomfort recommended for the rearing of animals. However, the sound pressure amplitude inside the barn with climate control system was greater than in the open barn. The light intensity was significantly lower in the closed barn when compared to the open barn (84.96 and 1,413.58 lx, respectively). The artificial lighting system distributed throughout the closed barn was not sufficient to maintain brightness within the recommended range for lactating cows. In addition, it was found that in the closed building with forced ventilation, the highest brightness values are located near the exhaust fans.","PeriodicalId":7924,"journal":{"name":"Agronomy research","volume":"18 1","pages":"689-698"},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Agronomy research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15159/AR.20.104","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Agricultural and Biological Sciences","Score":null,"Total":0}
引用次数: 3

Abstract

The housing system, called compost barn, is attracting the interest of several farmers. It allows dairy cows to remain in free movement inside a shed without any containment partitions like those used in freestall barns. In Brazil the compost barns with open sides are very common, but recently some closed barns with climatic control systems have been implemented. The objective of this work was to evaluate and compare lighting and noise levels in an open compost barn with natural ventilation and in a closed compost barn with a climate control system. The latter one is based on tunnel ventilation: inlet of air trough evaporative cellulose panels and exit through fans placed on the opposite wall. Through analysis of the collected data it was observed that the sound pressure recorded inside both analysed buildings did not exceed the ranges of noise discomfort recommended for the rearing of animals. However, the sound pressure amplitude inside the barn with climate control system was greater than in the open barn. The light intensity was significantly lower in the closed barn when compared to the open barn (84.96 and 1,413.58 lx, respectively). The artificial lighting system distributed throughout the closed barn was not sufficient to maintain brightness within the recommended range for lactating cows. In addition, it was found that in the closed building with forced ventilation, the highest brightness values are located near the exhaust fans.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
采用自然和强制通风的堆肥奶牛场的照明和噪音水平
这个住房系统被称为堆肥谷仓,吸引了一些农民的兴趣。它可以让奶牛在牛棚内自由活动,而不需要像独立式谷仓那样使用任何隔离隔板。在巴西,开放式的堆肥仓非常普遍,但最近已经实施了一些带有气候控制系统的封闭式谷仓。这项工作的目的是评估和比较具有自然通风的开放式堆肥仓和具有气候控制系统的封闭式堆肥仓的照明和噪音水平。后者是基于隧道通风:空气通过蒸发纤维素板进入,通过放置在对面墙上的风扇排出。通过对收集到的数据进行分析,观察到所分析的建筑物内记录的声压均未超过饲养动物所建议的噪音不适范围。有气候调节系统的粮仓内的声压幅值比露天粮仓大。封闭仓的光强显著低于开放仓,分别为84.96 lx和1413.58 lx。分布在封闭畜棚内的人工照明系统不足以将乳牛的亮度维持在推荐范围内。此外,还发现在强制通风的密闭建筑中,最高亮度值位于排风机附近。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Agronomy research
Agronomy research Agricultural and Biological Sciences-Agronomy and Crop Science
CiteScore
2.10
自引率
0.00%
发文量
0
审稿时长
7 weeks
期刊介绍: Agronomy Research is a peer-reviewed international Journal intended for publication of broad-spectrum original articles, reviews and short communications on actual problems of modern biosystems engineering including crop and animal science, genetics, economics, farm- and production engineering, environmental aspects, agro-ecology, renewable energy and bioenergy etc. in the temperate regions of the world.
期刊最新文献
Adaptation of various maize hybrids when grown for biomass New device for air disinfection with a shielded uv radiation and ozone Genetic components for fodder yield and agronomic characters in maize lines Intra-annual height growth dynamics of Scots and lodgepole pines and its relationship with meteorological parameters in central Latvia. Insects in chicken nutrition. A review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1