{"title":"Reliability of a novel method assessing muscle power and velocity during seated trunk rotations","authors":"E. Zemková","doi":"10.16926/PAR.2019.07.01","DOIUrl":null,"url":null,"abstract":"Introduction: Isometric and isokinetic dynamometers are mainly used for assessment of strength and endurance of core muscles. However, muscle power represents a more appropriate variable for evaluating of athlete performance that involve dynamic movements of the trunk. This study estimates test-retest reliability of trunk rotational power and velocity over a 1-week interval using the FiTRO Torso Isoinertial Dynamometer. Material and Methods: A group of 32 physically active men performed 5 trunk rotations to each side while seated with a barbell of 1 kg or 20 kg placed on their shoulders. Results: Results showed that assessment of peak and mean velocity in the acceleration phase of trunk rotations with 1 kg provides reliable results (ICC = 0.94 and 0.92 respectively, SEM = 7.0% and 7.3% respectively). However, peak and mean values of velocity and power obtained during trunk rotations with a weight of 20 kg should be interpreted with caution (ICC < 0.80, SEM > 10%). Conclusions: Such an assessment of trunk rotational power and velocity can be used in practice, however with a limitation of performing trunk rotations in a seated position and using lower loads.","PeriodicalId":43466,"journal":{"name":"Physical Activity Review","volume":"1 1","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physical Activity Review","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.16926/PAR.2019.07.01","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SPORT SCIENCES","Score":null,"Total":0}
引用次数: 5
Abstract
Introduction: Isometric and isokinetic dynamometers are mainly used for assessment of strength and endurance of core muscles. However, muscle power represents a more appropriate variable for evaluating of athlete performance that involve dynamic movements of the trunk. This study estimates test-retest reliability of trunk rotational power and velocity over a 1-week interval using the FiTRO Torso Isoinertial Dynamometer. Material and Methods: A group of 32 physically active men performed 5 trunk rotations to each side while seated with a barbell of 1 kg or 20 kg placed on their shoulders. Results: Results showed that assessment of peak and mean velocity in the acceleration phase of trunk rotations with 1 kg provides reliable results (ICC = 0.94 and 0.92 respectively, SEM = 7.0% and 7.3% respectively). However, peak and mean values of velocity and power obtained during trunk rotations with a weight of 20 kg should be interpreted with caution (ICC < 0.80, SEM > 10%). Conclusions: Such an assessment of trunk rotational power and velocity can be used in practice, however with a limitation of performing trunk rotations in a seated position and using lower loads.
期刊介绍:
Physical Activity Review aims to facilitate and enhance communication across all sub-disciplines of the sport sciences. The emphasis of the journal is on the human sciences, broadly defined, applied to sport and exercise. Subject areas suitable for publication include, but are not limited to the following fields: Sport Science Sport Pedagogy Physiology Biomechanics Sports theory and history Different aspects of martial arts Recreation and tourism Physiotherapy.