Liberação de flúor de materiais restauradores

A. Carvalho, J. Cury
{"title":"Liberação de flúor de materiais restauradores","authors":"A. Carvalho, J. Cury","doi":"10.1590/S0103-06631998000400011","DOIUrl":null,"url":null,"abstract":"Nowadays there are several types of restorative materials with fluoride release properties. Thus, the purpose of this study was to analyze the fluoride release from the following restorative materials, considering their different compositions. The materials used were: Chelon Fil-ESPE (CHE), Vitremer-3M (VIT), Variglass-DENTSPLY (VAR), Dyract-DENTSPLY (DYR) and Tetric-VIVADENT (TET). Six cylindrical samples (area = 1.65 cm2) of each material were prepared; each sample was then suspended individually in a plastic tube containing 2.0 mL of deionized water. The water was changed daily during 15 days. Fluoride release was determined after buffering the solution with an equal volume of TISABII. For the fluoride analysis, a fluoride electrode, Orion 96-09, and an ionalyser Orion EA 940 were used. All materials showed the same pattern of fluoride release during the 15-day experiment; the greatest fluoride release occurred during the first days and then it decreased rapidly toward a constant level. The fluoride released (mean ± standard error) in mg F/cm2 were: CHE = 7.62 ± 0.73A, VIT = 5.91 ± 0.79B, VAR = 2.72 ± 0.25C, DYR = 1.50 ± 0.17D, TE = 0.136 ± 0.016E. Means followed by different letters were significant (5%). The results showed that the composition of restorative materials influenced significantly the fluoride release.","PeriodicalId":77611,"journal":{"name":"Revista de odontologia da Universidade de Sao Paulo","volume":"12 1","pages":"367-373"},"PeriodicalIF":0.0000,"publicationDate":"1998-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista de odontologia da Universidade de Sao Paulo","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/S0103-06631998000400011","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

Nowadays there are several types of restorative materials with fluoride release properties. Thus, the purpose of this study was to analyze the fluoride release from the following restorative materials, considering their different compositions. The materials used were: Chelon Fil-ESPE (CHE), Vitremer-3M (VIT), Variglass-DENTSPLY (VAR), Dyract-DENTSPLY (DYR) and Tetric-VIVADENT (TET). Six cylindrical samples (area = 1.65 cm2) of each material were prepared; each sample was then suspended individually in a plastic tube containing 2.0 mL of deionized water. The water was changed daily during 15 days. Fluoride release was determined after buffering the solution with an equal volume of TISABII. For the fluoride analysis, a fluoride electrode, Orion 96-09, and an ionalyser Orion EA 940 were used. All materials showed the same pattern of fluoride release during the 15-day experiment; the greatest fluoride release occurred during the first days and then it decreased rapidly toward a constant level. The fluoride released (mean ± standard error) in mg F/cm2 were: CHE = 7.62 ± 0.73A, VIT = 5.91 ± 0.79B, VAR = 2.72 ± 0.25C, DYR = 1.50 ± 0.17D, TE = 0.136 ± 0.016E. Means followed by different letters were significant (5%). The results showed that the composition of restorative materials influenced significantly the fluoride release.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
从修复材料中释放氟化物
目前有几种具有氟释放特性的修复材料。因此,本研究的目的是分析以下修复材料的氟释放,考虑它们的不同成分。使用的材料有:Chelon file - espe (CHE)、Vitremer-3M (VIT)、Variglass-DENTSPLY (VAR)、Dyract-DENTSPLY (DYR)和Tetric-VIVADENT (TET)。每种材料制备了6个圆柱形样品(面积= 1.65 cm2);然后将每个样品分别悬浮在含有2.0 mL去离子水的塑料管中。在15天里,每天换一次水。用等体积的TISABII缓冲溶液后测定氟化物释放量。氟化物分析使用了Orion 96-09氟化物电极和Orion EA 940离子分析仪。在15天的实验中,所有材料的氟化物释放模式相同;氟化物释放量在头几天最大,然后迅速下降到一个恒定的水平。氟释放(平均±标准误差)(mg F/cm2): CHE = 7.62±0.73A, VIT = 5.91±0.79B, VAR = 2.72±0.25C, DYR = 1.50±0.17D, TE = 0.136±0.016E。不同字母后面的平均值显著(5%)。结果表明,修复材料的组成对氟的释放有显著影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
"Resisting social identity threat and maintaining resilience": A qualitative study of Chinese parents following the loss of an only child. Study of surface alterations of composite and ionomeric materials submitted to simulation of a high cariogenic challenge Infiltração marginal de agentes cimentantes em coroas metálicas fundidas Efeito da desinfeccao por aerossois sobre a capacidade de umedecimento de moldes de polieter por gesso tipo IV Microinfiltração em dentes decíduos em função de materiais restauradores e condicionamento ácido
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1