{"title":"Safety Assessment of H-Coil for Nursing Staff in Deep Transcranial Magnetic Stimulation","authors":"Mai Lu;Shoogo Ueno","doi":"10.1109/LMAG.2022.3198370","DOIUrl":null,"url":null,"abstract":"This work investigates the exposure experienced by the nursing staff executing deep transcranial magnetic stimulations (TMS) using H-coil. The safety assessment was implemented by employing the H-coil and realistic human model. The 144 relative positions of the H-coil with respect to the TMS operator body were considered, including the distance and vertical height. Dependence of the magnetic flux density and induced electric fields in the human model were obtained by using the impedance method. Results were compared with the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines. Regarding the occupational exposure, safe distances of 120 and 100 cm are derived from the ICNIRP reference level (RL) and basic restriction (BR), respectively. At the distance of 100 cm, the exposure level does not exceed the ICNIRP BR, and although the exposure level exceeds the RL, continued exposure is allowed. The findings suggest that nursing staff should stand at least 100 cm apart from the H-coil.","PeriodicalId":13040,"journal":{"name":"IEEE Magnetics Letters","volume":"13 ","pages":"1-5"},"PeriodicalIF":1.1000,"publicationDate":"2022-08-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/iel7/5165412/9656771/09857568.pdf","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Magnetics Letters","FirstCategoryId":"101","ListUrlMain":"https://ieeexplore.ieee.org/document/9857568/","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 1
Abstract
This work investigates the exposure experienced by the nursing staff executing deep transcranial magnetic stimulations (TMS) using H-coil. The safety assessment was implemented by employing the H-coil and realistic human model. The 144 relative positions of the H-coil with respect to the TMS operator body were considered, including the distance and vertical height. Dependence of the magnetic flux density and induced electric fields in the human model were obtained by using the impedance method. Results were compared with the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines. Regarding the occupational exposure, safe distances of 120 and 100 cm are derived from the ICNIRP reference level (RL) and basic restriction (BR), respectively. At the distance of 100 cm, the exposure level does not exceed the ICNIRP BR, and although the exposure level exceeds the RL, continued exposure is allowed. The findings suggest that nursing staff should stand at least 100 cm apart from the H-coil.
期刊介绍:
IEEE Magnetics Letters is a peer-reviewed, archival journal covering the physics and engineering of magnetism, magnetic materials, applied magnetics, design and application of magnetic devices, bio-magnetics, magneto-electronics, and spin electronics. IEEE Magnetics Letters publishes short, scholarly articles of substantial current interest.
IEEE Magnetics Letters is a hybrid Open Access (OA) journal. For a fee, authors have the option making their articles freely available to all, including non-subscribers. OA articles are identified as Open Access.