Jonathan W Kilgallon, Joseph Cave, Emily J. Cushion, S. Joffe, J. Tallent
{"title":"Reliability of the Coach’s Eye Goniometer Application during Squat Exercise","authors":"Jonathan W Kilgallon, Joseph Cave, Emily J. Cushion, S. Joffe, J. Tallent","doi":"10.18276/cej.2022.2-05","DOIUrl":null,"url":null,"abstract":"This study examined the test re-test, intrarater and interrater reliability of joint kinematics from the coach’s Eye smartphone application. Twenty-two males completed a 1-repetition maximum (1-rM) assessment followed by 2 identical sessions using 5 incremental loads (20, 40, 60, 80, 90% 1-rM). Peak flexion angles at the hip, knee, and ankle joints were assessed using 1 experienced practitioner and 1 inexperienced practitioner. the acceptable reliability thresholds were defined as intraclass correlation coefficient (Icc) r > 0.70 and coefficient of variation cv ≤ 10%. the test re-test reliability of peak hip and knee flexion were reliable across 20–90% 1-rM (r > 0.64; cv < 4.2%), whereas peak ankle flexion was not reliable at any loaded condition (r > 0.70; cv < 20.4%). no significant differences were detected between trials (p > 0.11). the intrarater reliability was near perfect (r > 0.90) except for peak ankle flexion (r > 0.85). the interrater reliability was nearly perfect (r > 0.91) except for hip flexion at 80% 1-rM and ankle flexion at 20% (r > 0.77). concludingly, the coach’s Eye application can produce repeatable assessments of joint kinematics using either a single examiner or 2 examiners, regardless of experience level. the coach’s Eye can accurately monitor squat depth. Participants were allowed to use their own lifting footwear.","PeriodicalId":36509,"journal":{"name":"Central European Journal of Sport Sciences and Medicine","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Central European Journal of Sport Sciences and Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18276/cej.2022.2-05","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 0
Abstract
This study examined the test re-test, intrarater and interrater reliability of joint kinematics from the coach’s Eye smartphone application. Twenty-two males completed a 1-repetition maximum (1-rM) assessment followed by 2 identical sessions using 5 incremental loads (20, 40, 60, 80, 90% 1-rM). Peak flexion angles at the hip, knee, and ankle joints were assessed using 1 experienced practitioner and 1 inexperienced practitioner. the acceptable reliability thresholds were defined as intraclass correlation coefficient (Icc) r > 0.70 and coefficient of variation cv ≤ 10%. the test re-test reliability of peak hip and knee flexion were reliable across 20–90% 1-rM (r > 0.64; cv < 4.2%), whereas peak ankle flexion was not reliable at any loaded condition (r > 0.70; cv < 20.4%). no significant differences were detected between trials (p > 0.11). the intrarater reliability was near perfect (r > 0.90) except for peak ankle flexion (r > 0.85). the interrater reliability was nearly perfect (r > 0.91) except for hip flexion at 80% 1-rM and ankle flexion at 20% (r > 0.77). concludingly, the coach’s Eye application can produce repeatable assessments of joint kinematics using either a single examiner or 2 examiners, regardless of experience level. the coach’s Eye can accurately monitor squat depth. Participants were allowed to use their own lifting footwear.