Research on Slot-pole Combination in High-power Direct-drive PM Vernier Generator for Fractional Frequency Transmission System

Zhidong Yuan;Shaofeng Jia;Deliang Liang;Xiuli Wang;Yong Yang
{"title":"Research on Slot-pole Combination in High-power Direct-drive PM Vernier Generator for Fractional Frequency Transmission System","authors":"Zhidong Yuan;Shaofeng Jia;Deliang Liang;Xiuli Wang;Yong Yang","doi":"10.30941/CESTEMS.2022.00056","DOIUrl":null,"url":null,"abstract":"Offshore wind energy is an important part of clean energy, and the adoption of wind energy to generate electricity will contribute to the implementation of the carbon peaking and carbon neutrality goals. The combination of the fractional frequency transmission system (FFTS) and the direct-drive wind turbine generator will be beneficial to the development of the offshore wind power industry. The use of fractional frequency in FFTS is beneficial to the transmission of electrical energy, but it will also lead to an increase in the volume and weight of the generator, which is unfavorable for wind power generation. Improving the torque density of the generator can effectively reduce the volume of the generators. The vernier permanent magnet machine (VPM) operates on the magnetic flux modulation principle and has the merits of high torque density. In the field of electric machines, the vernier machine based on the principle of magnetic flux modulation has been proved its feasibility to reduce the volume and weight. However, in the field of low-speed direct-drive machines for high-power fractional frequency power generation, there are still few related researches. Therefore, this paper studies the application of magnetic flux modulation in fractional frequency and high-power direct-drive wind turbine generators, mainly analyzes the influence of different pole ratios and different pole pairs on the generator, and draws some conclusions to provide reference for the design of wind turbine generators.","PeriodicalId":100229,"journal":{"name":"CES Transactions on Electrical Machines and Systems","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/iel7/7873789/10004905/10004930.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"CES Transactions on Electrical Machines and Systems","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10004930/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Offshore wind energy is an important part of clean energy, and the adoption of wind energy to generate electricity will contribute to the implementation of the carbon peaking and carbon neutrality goals. The combination of the fractional frequency transmission system (FFTS) and the direct-drive wind turbine generator will be beneficial to the development of the offshore wind power industry. The use of fractional frequency in FFTS is beneficial to the transmission of electrical energy, but it will also lead to an increase in the volume and weight of the generator, which is unfavorable for wind power generation. Improving the torque density of the generator can effectively reduce the volume of the generators. The vernier permanent magnet machine (VPM) operates on the magnetic flux modulation principle and has the merits of high torque density. In the field of electric machines, the vernier machine based on the principle of magnetic flux modulation has been proved its feasibility to reduce the volume and weight. However, in the field of low-speed direct-drive machines for high-power fractional frequency power generation, there are still few related researches. Therefore, this paper studies the application of magnetic flux modulation in fractional frequency and high-power direct-drive wind turbine generators, mainly analyzes the influence of different pole ratios and different pole pairs on the generator, and draws some conclusions to provide reference for the design of wind turbine generators.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
大功率直驱永磁调速器槽极组合的研究
海上风能是清洁能源的重要组成部分,采用风能发电将有助于实现碳达峰和碳中和目标。分数频率传输系统(FFTS)和直接驱动风力发电机的结合将有利于海上风电行业的发展。在FFTS中使用分数频率有利于电能的传输,但也会导致发电机的体积和重量增加,这对风力发电不利。提高发电机的转矩密度可以有效地减小发电机的体积。游标永磁电机采用磁通调制原理,具有转矩密度大的优点。在电机领域,基于磁通量调制原理的游标机床已被证明其减小体积和重量的可行性。然而,在用于大功率分频发电的低速直驱电机领域,相关研究仍然很少。因此,本文研究了磁通调制在分频和大功率直驱风力发电机组中的应用,主要分析了不同极比和不同极对对对发电机的影响,得出了一些结论,为风力发电机组的设计提供参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Review of Fault-Tolerant Control for Motor Inverter Failure with Operational Quality Considered Winding Function Model-Based Performance Evaluation of a PM Transverse Flux Generator for Applications in Direct-Drive Systems Transient AC Overvoltage Suppression Orientated Reactive Power Control of the Wind Turbine in the LCC-HVDC Sending Grid Coordinated Capacitor Voltage Balancing Method for Cascaded H-Bridge Inverter with Supercapacitor and DC-DC Stage Analytical Model and Topology Optimization of Doubly-Fed Induction Generator
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1