{"title":"The possibility for gamma and UV radiation detection based on electrical breakdown time delay measurement in krypton and xenon filled diodes","authors":"M. Pejović, E. Živanović, Čedomir Belić","doi":"10.2298/ntrp2103243p","DOIUrl":null,"url":null,"abstract":"The paper presents results of electrical breakdown time delay mean value t?d as a function of relaxation time ? (memory curve) for krypton and xenon-filled diodes at 270 Pa pressure. Memory curves were obtained for the cases without radiation as well as in the presence of gamma and UV radiation. It was shown that significant influence of UV radiation to t?d can be observed for ? ? 100 ms, as well as gamma radiation for ? ? 103 ms. Laue's distribution was also investigated for electrical breakdown time delay data sets td, obtained for ? ? 150 ms, without radiation as well as in the presence of gamma and UV radiation. It was shown that for all these data sets Laue's distribution stands, except for the case when krypton-filled tube was subjected to UV radiation. On the basis of the obtained results, the throughout analysis was performed with the aim to investigate possible application of these diodes as sensors of gamma and UV radiation.","PeriodicalId":49734,"journal":{"name":"Nuclear Technology & Radiation Protection","volume":"1 1","pages":""},"PeriodicalIF":0.9000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Technology & Radiation Protection","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.2298/ntrp2103243p","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 5
Abstract
The paper presents results of electrical breakdown time delay mean value t?d as a function of relaxation time ? (memory curve) for krypton and xenon-filled diodes at 270 Pa pressure. Memory curves were obtained for the cases without radiation as well as in the presence of gamma and UV radiation. It was shown that significant influence of UV radiation to t?d can be observed for ? ? 100 ms, as well as gamma radiation for ? ? 103 ms. Laue's distribution was also investigated for electrical breakdown time delay data sets td, obtained for ? ? 150 ms, without radiation as well as in the presence of gamma and UV radiation. It was shown that for all these data sets Laue's distribution stands, except for the case when krypton-filled tube was subjected to UV radiation. On the basis of the obtained results, the throughout analysis was performed with the aim to investigate possible application of these diodes as sensors of gamma and UV radiation.
期刊介绍:
Nuclear Technology & Radiation Protection is an international scientific journal covering the wide range of disciplines involved in nuclear science and technology as well as in the field of radiation protection. The journal is open for scientific papers, short papers, review articles, and technical papers dealing with nuclear power, research reactors, accelerators, nuclear materials, waste management, radiation measurements, and environmental problems. However, basic reactor physics and design, particle and radiation transport theory, and development of numerical methods and codes will also be important aspects of the editorial policy.