{"title":"EVALUATION OF GLOVE INTEGRITY AFTER MULTIPLE WASHES WITH DISINFECTANT","authors":"W. Chai, Z. Yusof, J. Marhazlinda, C. N. Shim, M. Y. Lee, P. Nambiar","doi":"10.22452/ADUM.VOL19NO2.1","DOIUrl":null,"url":null,"abstract":"Background: In an academic setting due to financial constrain, it is not uncommon during non-surgical procedures dental students and clinical supervisors wash their gloved hands with disinfectants in between patients or when touching on non-contaminated objects. Whether this practice could cause any deterioration of the glove and expose clinicians and patients to infectious micro-organisms was a concern. Aim: The aim of this study was to investigate the effect of multiple washes of gloved hands with a disinfectant on the integrity of the gloves. Methods: Three brands of commonly used gloves in a dental school were tested for leaks after multiple washes with a disinfectant. Thirty pairs of each type of gloves were subjected to 0, 1, 5, 10, 20 and 30 washes with a disinfectant solution at a 5-minute interval between each wash. After each washing cycle, the gloves were filled with 1L of water and hanged for 2 minutes to observe any signs of water leaks. Results: The results showed that the type of gloves and number of washes were significantly associated with the leakage rates (p<0.001). Washing of gloves for more than 5 times were at least 6 times higher to suffer from leakage (OR=6.23, 95% CI=2.14–18.08). Powdered gloves were almost 13 times higher to leak in all washes (OR=12.78, 95% CI= 4.40–37.14) and were almost 25 times more likely to leak when washed for more than 5 times (OR = 24.92, 95% CI = 5.79 – 107.21) when compared to the non-powdered gloves. Conclusion: The practice of washing gloved hands with a disinfectant deteriorates the integrity of the gloves.","PeriodicalId":75515,"journal":{"name":"Annals of dentistry","volume":"44 1","pages":"43-50"},"PeriodicalIF":0.0000,"publicationDate":"2012-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22452/ADUM.VOL19NO2.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: In an academic setting due to financial constrain, it is not uncommon during non-surgical procedures dental students and clinical supervisors wash their gloved hands with disinfectants in between patients or when touching on non-contaminated objects. Whether this practice could cause any deterioration of the glove and expose clinicians and patients to infectious micro-organisms was a concern. Aim: The aim of this study was to investigate the effect of multiple washes of gloved hands with a disinfectant on the integrity of the gloves. Methods: Three brands of commonly used gloves in a dental school were tested for leaks after multiple washes with a disinfectant. Thirty pairs of each type of gloves were subjected to 0, 1, 5, 10, 20 and 30 washes with a disinfectant solution at a 5-minute interval between each wash. After each washing cycle, the gloves were filled with 1L of water and hanged for 2 minutes to observe any signs of water leaks. Results: The results showed that the type of gloves and number of washes were significantly associated with the leakage rates (p<0.001). Washing of gloves for more than 5 times were at least 6 times higher to suffer from leakage (OR=6.23, 95% CI=2.14–18.08). Powdered gloves were almost 13 times higher to leak in all washes (OR=12.78, 95% CI= 4.40–37.14) and were almost 25 times more likely to leak when washed for more than 5 times (OR = 24.92, 95% CI = 5.79 – 107.21) when compared to the non-powdered gloves. Conclusion: The practice of washing gloved hands with a disinfectant deteriorates the integrity of the gloves.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
消毒剂多次洗涤后手套完整性的评价
背景:在学术环境中,由于财政限制,在非外科手术过程中,牙科学生和临床导师在病人之间或接触未受污染的物体时用消毒剂洗手并不罕见。这种做法是否会导致手套变质,并使临床医生和患者暴露于传染性微生物中,这是一个值得关注的问题。目的:本研究的目的是探讨用消毒剂多次清洗戴手套的手对手套完整性的影响。方法:对某牙科学校常用的3种手套,用消毒液多次清洗后进行泄漏检测。每种类型的30双手套分别用消毒液洗涤0、1、5、10、20和30次,每次洗涤间隔5分钟。每个洗涤周期结束后,将手套注满1L水,悬挂2分钟,观察是否有漏水的迹象。结果:手套种类和洗涤次数与泄漏率有显著相关性(p<0.001)。手套清洗5次以上至少6倍以上发生渗漏(OR=6.23, 95% CI=2.14 ~ 18.08)。在所有洗涤中,有粉手套的泄漏率几乎是无粉手套的13倍(OR=12.78, 95% CI= 4.40-37.14),当洗涤超过5次时,泄漏率几乎是无粉手套的25倍(OR= 24.92, 95% CI= 5.79 - 107.21)。结论:用消毒液洗手会破坏手套的完整性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Profile of Patients with Maxillofacial Fracture in Emergency Department, Head-Neck Surgery Division, Dr. Soetomo Public Hospital Surabaya in 2020 Detection of Genetic Alterations in Oral Squamous Cell Carcinoma Using Multiplex Ligation-Dependent Probe Amplification (MLPA) COVID-19 Impact on Dental Clinical Education: An Observational Narrative Misconceptions, Hesitancy and Efficacy of COVID-19 Vaccination in Dental Surgeons Working in A Teaching Dental Hospital, Peshawar Presence of the Periodontal Bacterium Porphyromonas gingivalis in Patients With and Without Cancer: A Meta-analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1