Reliability of the RunScribe™ system to determine kinematic variables of the pelvis during locomotion at different speeds

Pub Date : 2022-01-01 DOI:10.37190/abb-02073-2022-03
Aitor Marcos-Blanco, F. García-Pinillos, Alejandro Molina-Molina, D. Jaén-Carrillo, V. Soto-Hermoso, Santiago A. Ruiz-Alias
{"title":"Reliability of the RunScribe™ system to determine kinematic variables of the pelvis during locomotion at different speeds","authors":"Aitor Marcos-Blanco, F. García-Pinillos, Alejandro Molina-Molina, D. Jaén-Carrillo, V. Soto-Hermoso, Santiago A. Ruiz-Alias","doi":"10.37190/abb-02073-2022-03","DOIUrl":null,"url":null,"abstract":"Purpose This study aimed to determine the reliability of the RunScribe™ system to measure kinematic variables of the pelvis during walking and running. Methods In this study, a treadmill protocol was implemented where the participants (n=23) completed 3 sets of 1 minute at 5, 10 and 15 km.h-1. Results All the recorded measurements during walking reported a low reliability with coefficients of variation (CV) greater than 10% in all variables and small-moderate intraclass correlation coefficient (ICC) (< 0.6) in seven out of ten variables. Similarly, the CVs reported in running were greater than 10% except for the maximum angular rate in the obliquity of the pelvis and the vertical oscillation that together with the angular velocity variables showed almost perfect ICCs (> 0.92). Conclusions Therefore, the data obtained suggests that the RunScribe™ system with 3 IMUs does not provide reliable metrics about the kinematics of the pelvis during locomotion (i.e., walking and running).","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.37190/abb-02073-2022-03","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose This study aimed to determine the reliability of the RunScribe™ system to measure kinematic variables of the pelvis during walking and running. Methods In this study, a treadmill protocol was implemented where the participants (n=23) completed 3 sets of 1 minute at 5, 10 and 15 km.h-1. Results All the recorded measurements during walking reported a low reliability with coefficients of variation (CV) greater than 10% in all variables and small-moderate intraclass correlation coefficient (ICC) (< 0.6) in seven out of ten variables. Similarly, the CVs reported in running were greater than 10% except for the maximum angular rate in the obliquity of the pelvis and the vertical oscillation that together with the angular velocity variables showed almost perfect ICCs (> 0.92). Conclusions Therefore, the data obtained suggests that the RunScribe™ system with 3 IMUs does not provide reliable metrics about the kinematics of the pelvis during locomotion (i.e., walking and running).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
RunScribe™系统在不同速度下确定骨盆运动变量的可靠性
本研究旨在确定RunScribe™系统在步行和跑步过程中测量骨盆运动学变量的可靠性。方法本研究采用跑步机方案,参与者(n=23)以5、10和15 km.h-1的速度完成3组1分钟的运动。结果所有记录的步行测量结果均为低信度,所有变量的变异系数(CV)均大于10%,10个变量中有7个变量的小-中度类内相关系数(ICC) < 0.6。同样,除了骨盆倾角和垂直振荡的最大角速率以及角速度变量显示几乎完美的ICCs(> 0.92)外,跑步时报告的CVs均大于10%。因此,所获得的数据表明,带有3个imu的RunScribe™系统不能提供有关骨盆运动(即行走和跑步)期间运动学的可靠指标。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1