Experimental Study on the Relationship Between the Change of Free available Chlorine and the Increase Rate of Disinfection by-products according to Operating Conditions of three Types of Sodium Hypochlorite

N. Park, Suk-min Yoon, Sang-min Park, Mi-ae Yun, Young-joo Lee
{"title":"Experimental Study on the Relationship Between the Change of Free available Chlorine and the Increase Rate of Disinfection by-products according to Operating Conditions of three Types of Sodium Hypochlorite","authors":"N. Park, Suk-min Yoon, Sang-min Park, Mi-ae Yun, Young-joo Lee","doi":"10.4491/ksee.2022.44.12.534","DOIUrl":null,"url":null,"abstract":"Objectives : This study was conducted to suggest field operating conditions that can minimize disinfection by-products for three types of sodium hypochlorite.Methods : In this study, changes in free available chlorine, chlorate and bromate were analyzed according to storage temperature, storage time and presence or absence of sunlight for three types of sodium hypochlorite(two types of bleach and one type of sodium hypochlorite made on-site hypochlorite generator).Results and Discussion : In the case of bleach with 12% free available chlorine, when operating with a target of 10% of more of free available chlorine, the storage time for each storage temperature was 3 days at 40℃, 13 days at 30℃, 27 days at 20℃, 85 days at 10℃, and 200 days at 5℃. In the case of bleach with 5% free available chlorine, when operating with a target of 4% of more of free available chlorine, the storage time for each storage temperature was 37 days at 35℃, 255 days at 20℃, 1,343 days at 10℃, and 4,821 days at 4℃. In the case of sodium hypochlorite with 0.8% free available chlorine made on-site hypochlorite generator, when operating with a target of 0.7% of more of free available chlorine, the storage time for each storage temperature was 10 days at 3 5℃, 42 days at 20℃, 470 days at 10℃, and 1,770 days at 4°C. As a result of evaluating the quality change according to the presence or absence of UV protection, the free available chlorine decreased rapidly when exposed to sunlight, whereas the free available chlorine decreased slowly in the case of indoor storage.Conclusion : Bleach with 12% free available chlorine can be stored for about 60 days at 15℃, and bleach with 5% free available chlorine can be used within about 6 months at 15℃. And sodium hypochlorite with 0.8% free available chlorine can be used within 10 days at room temperature. In addition, when storing sodium hypochlorite, it is suggested that it be stored indoors protected from sunlight.","PeriodicalId":52756,"journal":{"name":"daehanhwangyeonggonghaghoeji","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"daehanhwangyeonggonghaghoeji","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4491/ksee.2022.44.12.534","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives : This study was conducted to suggest field operating conditions that can minimize disinfection by-products for three types of sodium hypochlorite.Methods : In this study, changes in free available chlorine, chlorate and bromate were analyzed according to storage temperature, storage time and presence or absence of sunlight for three types of sodium hypochlorite(two types of bleach and one type of sodium hypochlorite made on-site hypochlorite generator).Results and Discussion : In the case of bleach with 12% free available chlorine, when operating with a target of 10% of more of free available chlorine, the storage time for each storage temperature was 3 days at 40℃, 13 days at 30℃, 27 days at 20℃, 85 days at 10℃, and 200 days at 5℃. In the case of bleach with 5% free available chlorine, when operating with a target of 4% of more of free available chlorine, the storage time for each storage temperature was 37 days at 35℃, 255 days at 20℃, 1,343 days at 10℃, and 4,821 days at 4℃. In the case of sodium hypochlorite with 0.8% free available chlorine made on-site hypochlorite generator, when operating with a target of 0.7% of more of free available chlorine, the storage time for each storage temperature was 10 days at 3 5℃, 42 days at 20℃, 470 days at 10℃, and 1,770 days at 4°C. As a result of evaluating the quality change according to the presence or absence of UV protection, the free available chlorine decreased rapidly when exposed to sunlight, whereas the free available chlorine decreased slowly in the case of indoor storage.Conclusion : Bleach with 12% free available chlorine can be stored for about 60 days at 15℃, and bleach with 5% free available chlorine can be used within about 6 months at 15℃. And sodium hypochlorite with 0.8% free available chlorine can be used within 10 days at room temperature. In addition, when storing sodium hypochlorite, it is suggested that it be stored indoors protected from sunlight.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
三种类型次氯酸钠不同操作条件下游离有效氯变化与消毒副产物增幅关系的实验研究
目的:本研究旨在建议现场操作条件,以尽量减少三种类型的次氯酸钠消毒副产物。方法:本研究分析了三种次氯酸钠(两种漂白剂和一种现场制作的次氯酸钠)在贮存温度、贮存时间和有无光照条件下的游离有效氯、氯酸盐和溴酸盐的变化。结果与讨论:以游离有效氯为12%的漂白剂为例,当游离有效氯的目标量增加10%时,每种储存温度下的储存时间分别为:40℃下3天、30℃下13天、20℃下27天、10℃下85天、5℃下200天。以游离有效氯为5%的漂白剂为例,当游离有效氯的目标量为4%以上时,每种储存温度下的储存时间分别为35℃下37天、20℃下255天、10℃下1343天、4℃下4821天。以游离有效氯含量为0.8%的次氯酸钠自制现场次氯酸盐发生器为例,在游离有效氯含量增加0.7%的目标下运行,各储存温度下的储存时间分别为:3.5℃下10天、20℃下42天、10℃下470天、4℃下1770天。根据有无紫外线防护来评价质量变化,暴露在阳光下时,游离有效氯下降迅速,而室内储存时,游离有效氯下降缓慢。结论:游离有效氯含量为12%的漂白剂在15℃下可保存60天左右,游离有效氯含量为5%的漂白剂在15℃下可保存6个月左右。含0.8%游离有效氯的次氯酸钠在室温下可在10天内使用。另外,储存次氯酸钠时,建议在室内避光存放。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
38
审稿时长
8 weeks
期刊最新文献
Comparative Analysis of Greenhouse Gas Emissions from Domestic Wastewater Treatment Processes by Modeling: Existing Estimation Methods vs Modeling A Study on Assessment of Carbon Absorption Footprint (CAF) and Forestation in Local Governments Greenhouse Gas Emissions of an Urban Water System in Korea: A case study of Paju city Evaluation of the Chemical Characteristics and Predictive Model of Water-Soluble Inorganic Ions for Fine Particulate Matter Generated in Pohang Characteristics of Soil Heavy Metal Contamination in the Intensive Livestock Farming Watersheds
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1