{"title":"Experimental plant for the physical-chemical treatment of groundwater polluted by Municipal Solid Waste (MSW) leachate, with ammonia recovery","authors":"M. Raboni, V. Torretta, P. Viotti, G. Urbini","doi":"10.4136/AMBI-AGUA.1250","DOIUrl":null,"url":null,"abstract":"The paper documents the results of the experimental treatment of groundwater (flow rate: 300 m 3 h -1 ) polluted by the leachate of an old MSW landfill (7 million tonnes) in northern Italy. The process consists of a coagulation-flocculation pre-treatment at pH > 11, and subsequent ammonia stripping, after heating the water to 35-38 °C by means of the biogas produced by the landfill. The stripped ammonia was recovered by absorption with sulfuric acid, producing a 30% solution of ammonium sulfate, which was reused as a base fertilizer. In addition, the paper reports important operational aspects related to the scaling of the stripping tower’s packing and its effect on pH and temperature profiles inside the towers caused by the closed loop, which recirculates the stripping air coming from the ammonia absorption towers with sulfuric acid. The average removal efficiency of ammonia reached 95.4% with an inlet mean concentration of 199.0 mg L -1 .","PeriodicalId":38374,"journal":{"name":"Revista Ambiente e Agua","volume":"57 1","pages":"22-32"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"33","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Ambiente e Agua","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4136/AMBI-AGUA.1250","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Environmental Science","Score":null,"Total":0}
引用次数: 33
Abstract
The paper documents the results of the experimental treatment of groundwater (flow rate: 300 m 3 h -1 ) polluted by the leachate of an old MSW landfill (7 million tonnes) in northern Italy. The process consists of a coagulation-flocculation pre-treatment at pH > 11, and subsequent ammonia stripping, after heating the water to 35-38 °C by means of the biogas produced by the landfill. The stripped ammonia was recovered by absorption with sulfuric acid, producing a 30% solution of ammonium sulfate, which was reused as a base fertilizer. In addition, the paper reports important operational aspects related to the scaling of the stripping tower’s packing and its effect on pH and temperature profiles inside the towers caused by the closed loop, which recirculates the stripping air coming from the ammonia absorption towers with sulfuric acid. The average removal efficiency of ammonia reached 95.4% with an inlet mean concentration of 199.0 mg L -1 .
这篇论文记录了意大利北部一个旧的城市生活垃圾填埋场(700万吨)的渗滤液污染地下水的实验处理结果(流速:300米3小时-1)。该工艺包括pH值为bbbb11的混凝-絮凝预处理,然后利用垃圾填埋场产生的沼气将水加热至35-38℃后进行氨汽提。将剥离后的氨用硫酸吸附回收,得到30%的硫酸铵溶液,作为基肥再利用。此外,本文还报道了与汽提塔填料结垢及其对塔内pH和温度分布的影响有关的重要操作方面,该影响是由闭环引起的,该闭环将来自氨吸收塔的汽提空气与硫酸再循环。进水平均浓度为199.0 mg L -1时,氨的平均去除率达95.4%。