{"title":"In-vitro Measurement of Glucose Concentration in Human Blood Plasma Mixed Intralipid Phantom Samples by Using Modulated Ultrasound and Infrared Light","authors":"Anuj Srivastava, Chowdhury, Shiru Sharma, Neeraj Sharma","doi":"10.9734/BBJ/2016/24861","DOIUrl":null,"url":null,"abstract":"Non-invasive blood glucose measurement is one of most innovative domain in Biomedical Engineering. Multiple methodologies have-been introduced over last few decades to fulfil the clinical requirement for non-invasive glucose measurement in human beings, however, without a successful breakthrough. This research article uses modulated ultrasound with infrared light-based technique to study glucose-induced variations in human blood plasma mixed Intralipid TM phantom samples using infrared light of 940 nm and 40 kHz central frequency based ultrasonic transmitter unit. The test uses blood samples of 30 study subjects during oral glucose tolerance test and fasting, postprandial and random stages based blood glucose tests respectively. The result as obtained from oral glucose tolerance tests and fasting, postprandial and random stages blood Original Research Article","PeriodicalId":90120,"journal":{"name":"British biotechnology journal","volume":"13 1","pages":"1-14"},"PeriodicalIF":0.0000,"publicationDate":"2016-01-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"British biotechnology journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9734/BBJ/2016/24861","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
Abstract
Non-invasive blood glucose measurement is one of most innovative domain in Biomedical Engineering. Multiple methodologies have-been introduced over last few decades to fulfil the clinical requirement for non-invasive glucose measurement in human beings, however, without a successful breakthrough. This research article uses modulated ultrasound with infrared light-based technique to study glucose-induced variations in human blood plasma mixed Intralipid TM phantom samples using infrared light of 940 nm and 40 kHz central frequency based ultrasonic transmitter unit. The test uses blood samples of 30 study subjects during oral glucose tolerance test and fasting, postprandial and random stages based blood glucose tests respectively. The result as obtained from oral glucose tolerance tests and fasting, postprandial and random stages blood Original Research Article