B. Dzeletovic, Ivana Milanović, Đorđe Antonijević, Jovan Badnjar, Zoran Petrov, Violeta Petrovic, N. Teodorović
{"title":"Radiopacity of Premixed calcium silicate-based endodontic sealers","authors":"B. Dzeletovic, Ivana Milanović, Đorđe Antonijević, Jovan Badnjar, Zoran Petrov, Violeta Petrovic, N. Teodorović","doi":"10.5937/asn2184256d","DOIUrl":null,"url":null,"abstract":"Background: Premixedcalcium silicate-based sealers are ready-to-use, injectable materials with advantageous biological properties that create environment favorable for periapical tissues repair and health. The aim of our study was to examine the radiopacities of premixed calcium silicate-based sealers:TotalFill BCSealer, EndoSequence BC Sealer, Ceraseal, Bio-C Sealer and to compare them with epoxy-basedsealer, AH Plus. Material and methods: Three specimens (2 mm thick and 5 mm in diameter) of each sealer were radiographed using charge-coupled device-baseddigital sensor (Trophy Radiology, Cedex, France) along with an aluminum stepwedge reference.For radiopacity determination, a graph of the logarithm of aluminum thickness versus radiographic density was plotted and a calibration curve was generated. Radiopacities were assessed from the graph and presented as millimeters of aluminum per millimeter of material (mmAl).ANOVA with a post hoc Tukey test was used for statistical analysis and significance was set at 0.05. Results: Radiopacity values of EndoSequence BC Sealer and Bio-C Sealerwere significantly lower than radiopacities of Ceraseal and AH Plus. Differences in values between EndoSequence BC Sealer and Bio-C Sealer as well as between Ceraseal and AH Plus were nonsignificant. TotalFill BC Sealer was nonsignificantly different from all other sealers. Conclusion: Premixed calcium silicate-based endodontic sealers evaluated in our study had radiopacity values higher than 9 mmAl, in ascending order,from Bio-C Sealer, EndoSequence BC Sealer, TotalFill BC Sealer to Ceraseal.","PeriodicalId":39229,"journal":{"name":"Acta Stomatologica Naissi","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Stomatologica Naissi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5937/asn2184256d","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Premixedcalcium silicate-based sealers are ready-to-use, injectable materials with advantageous biological properties that create environment favorable for periapical tissues repair and health. The aim of our study was to examine the radiopacities of premixed calcium silicate-based sealers:TotalFill BCSealer, EndoSequence BC Sealer, Ceraseal, Bio-C Sealer and to compare them with epoxy-basedsealer, AH Plus. Material and methods: Three specimens (2 mm thick and 5 mm in diameter) of each sealer were radiographed using charge-coupled device-baseddigital sensor (Trophy Radiology, Cedex, France) along with an aluminum stepwedge reference.For radiopacity determination, a graph of the logarithm of aluminum thickness versus radiographic density was plotted and a calibration curve was generated. Radiopacities were assessed from the graph and presented as millimeters of aluminum per millimeter of material (mmAl).ANOVA with a post hoc Tukey test was used for statistical analysis and significance was set at 0.05. Results: Radiopacity values of EndoSequence BC Sealer and Bio-C Sealerwere significantly lower than radiopacities of Ceraseal and AH Plus. Differences in values between EndoSequence BC Sealer and Bio-C Sealer as well as between Ceraseal and AH Plus were nonsignificant. TotalFill BC Sealer was nonsignificantly different from all other sealers. Conclusion: Premixed calcium silicate-based endodontic sealers evaluated in our study had radiopacity values higher than 9 mmAl, in ascending order,from Bio-C Sealer, EndoSequence BC Sealer, TotalFill BC Sealer to Ceraseal.