Characteristics of lightweight aggregate concrete interfacial transition zone

V. Milovanović, V. Ducman, M. Radeka
{"title":"Characteristics of lightweight aggregate concrete interfacial transition zone","authors":"V. Milovanović, V. Ducman, M. Radeka","doi":"10.5937/grmk1403063M","DOIUrl":null,"url":null,"abstract":"The paper presents the characteristics of the interfacial zone between the lightweight aggregate produced on the basis of waste materials and binder matrix with the application of the methods SEM, EDS and the Vickers micro hardness test. On the basis of the SEM and EDS analysis, as well as the criteria for the atomic ratio of elements which compose some products of hydration, we can gain insight into the dominant composition of the interfacial zone. The values of the Vickers micro hardness test for four kinds of tested concrete after seven days of hydration is impossible to correlate with the composition of the interfacial zone in reliable way, whereas after twenty eight days the differences in values are insignificant.","PeriodicalId":40707,"journal":{"name":"Gradevnski Materijiali I Konstrukcije-Building Materials and Structures","volume":"57 1","pages":"63-77"},"PeriodicalIF":0.5000,"publicationDate":"2014-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gradevnski Materijiali I Konstrukcije-Building Materials and Structures","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5937/grmk1403063M","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 0

Abstract

The paper presents the characteristics of the interfacial zone between the lightweight aggregate produced on the basis of waste materials and binder matrix with the application of the methods SEM, EDS and the Vickers micro hardness test. On the basis of the SEM and EDS analysis, as well as the criteria for the atomic ratio of elements which compose some products of hydration, we can gain insight into the dominant composition of the interfacial zone. The values of the Vickers micro hardness test for four kinds of tested concrete after seven days of hydration is impossible to correlate with the composition of the interfacial zone in reliable way, whereas after twenty eight days the differences in values are insignificant.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
轻骨料混凝土界面过渡区特征
采用扫描电子显微镜(SEM)、能谱仪(EDS)和维氏显微硬度测试等方法,研究了废料制备的轻骨料与粘结剂基体的界面区特征。通过SEM和EDS分析,以及组成水化产物的元素的原子比标准,我们可以了解到界面区的主导成分。4种试验混凝土水化7天后的维氏显微硬度测试值与界面区成分之间的相关性不可靠,而水化28天后的维氏显微硬度测试值差异不显著。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
25.00%
发文量
4
审稿时长
4 weeks
期刊最新文献
Contribution of strain-hardening cementitious composites (SHCC) to shear resistance in hybrid reinforced concrete beams Domain reduction method: Formulation, possibilities, and examples for analyzing seismic soil-structure interaction Tensile membrane structure forces dependence on different parameters under point load action Railway bridges on interoperable lines: Aspect of track/bridge interaction Nonlinear Static vs. Incremental Dynamic Analysis of Infilled Frames with Open First Floor
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1