Femoral prosthesis alignment of augmented reality-assisted versus accelerometer-based navigation in total knee arthroplasty: A noninferiority analysis

IF 1.5 4区 医学 Q3 ORTHOPEDICS Journal of Orthopaedic Science Pub Date : 2024-11-01 DOI:10.1016/j.jos.2023.10.011
Sachiyuki Tsukada , Kazuha Kizaki , Masayoshi Saito , Kenji Kurosaka , Naoyuki Hirasawa , Hiroyuki Ogawa
{"title":"Femoral prosthesis alignment of augmented reality-assisted versus accelerometer-based navigation in total knee arthroplasty: A noninferiority analysis","authors":"Sachiyuki Tsukada ,&nbsp;Kazuha Kizaki ,&nbsp;Masayoshi Saito ,&nbsp;Kenji Kurosaka ,&nbsp;Naoyuki Hirasawa ,&nbsp;Hiroyuki Ogawa","doi":"10.1016/j.jos.2023.10.011","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><div>The purpose of this study was to examine the comparative precision of the augmented reality (AR)-assisted navigation system and the accelerometer-based navigation system in total knee arthroplasty (TKA).</div></div><div><h3>Materials and methods</h3><div>We performed noninferiority analysis in a retrospective cohort. The coronal alignment of femoral prosthesis was compared between 109 TKAs performed using the AR-assisted navigation system and 118 TKAs performed using the accelerometer-based navigation system. All femoral prostheses were planned to be positioned perpendicular to the mechanical axis of the femur. The primary outcome was the success rate of coronal alignment of the femoral prosthesis defined as alignment error relative to neutral alignment &lt;3°. We calculated the noninferiority margin as 7%-points using the 95%–95 % method and also confirmed the validity of the noninferiority margin using the fixed margin method. Noninferiority would be shown if the lower boundary of the 95 % confidence interval (CI) for the between-group difference in percentage of the success rate was not less than 0.93 (i.e., 1.00 − 0.07).</div></div><div><h3>Results</h3><div>Treatment success was achieved in 104 of 109 patients (95.4 %) in the AR-assisted navigation group and 110 of 118 (93.2 %) in the accelerometer-based navigation group. The risk ratio of success between the AR-assisted navigation group versus accelerometer-based navigation group was 1.02 (95 % CI, 0.96 to 1.09): the CIs did not include the noninferiority margin of 0.93.</div></div><div><h3>Conclusion</h3><div>The AR-assisted navigation system was noninferior to the accelerometer-based navigation system in terms of coronal alignment of the femoral prosthesis in TKA.</div></div>","PeriodicalId":16939,"journal":{"name":"Journal of Orthopaedic Science","volume":"29 6","pages":"Pages 1417-1422"},"PeriodicalIF":1.5000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Science","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S094926582300283X","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction

The purpose of this study was to examine the comparative precision of the augmented reality (AR)-assisted navigation system and the accelerometer-based navigation system in total knee arthroplasty (TKA).

Materials and methods

We performed noninferiority analysis in a retrospective cohort. The coronal alignment of femoral prosthesis was compared between 109 TKAs performed using the AR-assisted navigation system and 118 TKAs performed using the accelerometer-based navigation system. All femoral prostheses were planned to be positioned perpendicular to the mechanical axis of the femur. The primary outcome was the success rate of coronal alignment of the femoral prosthesis defined as alignment error relative to neutral alignment <3°. We calculated the noninferiority margin as 7%-points using the 95%–95 % method and also confirmed the validity of the noninferiority margin using the fixed margin method. Noninferiority would be shown if the lower boundary of the 95 % confidence interval (CI) for the between-group difference in percentage of the success rate was not less than 0.93 (i.e., 1.00 − 0.07).

Results

Treatment success was achieved in 104 of 109 patients (95.4 %) in the AR-assisted navigation group and 110 of 118 (93.2 %) in the accelerometer-based navigation group. The risk ratio of success between the AR-assisted navigation group versus accelerometer-based navigation group was 1.02 (95 % CI, 0.96 to 1.09): the CIs did not include the noninferiority margin of 0.93.

Conclusion

The AR-assisted navigation system was noninferior to the accelerometer-based navigation system in terms of coronal alignment of the femoral prosthesis in TKA.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
全膝关节置换术中增强现实辅助导航与基于加速度计导航的股骨假体对齐:非劣效性分析。
引言:本研究的目的是检验增强现实(AR)辅助导航系统和基于加速度计的导航系统在全膝关节置换术(TKA)中的相对精度。材料和方法:我们在回顾性队列中进行了非劣效性分析。比较了使用AR辅助导航系统进行的109次TKA和使用基于加速度计的导航系统执行的118次TKA之间的股骨假体冠状位对齐。所有股骨假体的位置都计划垂直于股骨的机械轴。主要结果是股骨假体冠状位对齐的成功率,定义为相对于中性对齐的对齐误差。结果:AR辅助导航组109名患者中有104名(95.4%)获得治疗成功,基于加速度计的导航组118名患者中的110名(93.2%)获得治疗成功。AR辅助导航组与基于加速度计的导航组之间的成功风险比为1.02(95%CI,0.96至1.09):CI不包括0.93的非劣性界限。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Orthopaedic Science
Journal of Orthopaedic Science 医学-整形外科
CiteScore
3.00
自引率
0.00%
发文量
290
审稿时长
90 days
期刊介绍: The Journal of Orthopaedic Science is the official peer-reviewed journal of the Japanese Orthopaedic Association. The journal publishes the latest researches and topical debates in all fields of clinical and experimental orthopaedics, including musculoskeletal medicine, sports medicine, locomotive syndrome, trauma, paediatrics, oncology and biomaterials, as well as basic researches.
期刊最新文献
Clinical characteristics and results after conservative treatment or interfascicular neurolysis of 100 limbs with spontaneous anterior interosseous nerve palsy: A prospective Japanese multicenter study. Minimal clinically important difference in the Japanese Orthopedic Association Score and shoulder 36 after arthroscopic rotator cuff repair in a Japanese population: A retrospective cohort study. What is the appropriate revascularisation approach in traumatic popliteal artery injury? Platelet-rich plasma in the treatment of delayed union and nonunion fractures: An umbrella meta-analysis. Analysis of cancer multigene panel testing for osteosarcoma in pediatric and adults using the center for cancer genomics and advanced therapeutics database in Japan.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1