Challenging coronary sinus lead placement for CRT: A modified "Anchoring balloon" technique.

IF 1.7 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Pace-Pacing and Clinical Electrophysiology Pub Date : 2024-07-01 Epub Date: 2023-11-06 DOI:10.1111/pace.14869
Ronpichai Chokesuwattanaskul, Nithi Tokavanich, Suphot Srimahachota
{"title":"Challenging coronary sinus lead placement for CRT: A modified \"Anchoring balloon\" technique.","authors":"Ronpichai Chokesuwattanaskul, Nithi Tokavanich, Suphot Srimahachota","doi":"10.1111/pace.14869","DOIUrl":null,"url":null,"abstract":"<p><p>An 80-year-old man with a history of complete heart block underwent dual chamber pacemaker implantation about a year ago. He returned to the hospital due to de novo heart failure caused by pacing-induced cardiomyopathy; hence, we planned to upgrade his pacemaker to a biventricular device. The initial strategy was to perform left bundle branch area pacing-optimized cardiac resynchronization therapy (LOT-CRT) with left bundle branch area pacing (LBBAP) combined with a coronary sinus (CS) lead. In this challenging case, the successful placement of a CS lead was hindered by a complicated combination of a large CS body linked to the left superior vena cava and a winding CS branch. However, utilizing readily available tools, such as the coronary balloon and Guide Plus II ST catheter, proved instrumental in overcoming these obstacles. As a result, LOT-CRT provided the patient with a safe alternative to surgical LV lead placement.</p>","PeriodicalId":54653,"journal":{"name":"Pace-Pacing and Clinical Electrophysiology","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pace-Pacing and Clinical Electrophysiology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1111/pace.14869","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/6 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

An 80-year-old man with a history of complete heart block underwent dual chamber pacemaker implantation about a year ago. He returned to the hospital due to de novo heart failure caused by pacing-induced cardiomyopathy; hence, we planned to upgrade his pacemaker to a biventricular device. The initial strategy was to perform left bundle branch area pacing-optimized cardiac resynchronization therapy (LOT-CRT) with left bundle branch area pacing (LBBAP) combined with a coronary sinus (CS) lead. In this challenging case, the successful placement of a CS lead was hindered by a complicated combination of a large CS body linked to the left superior vena cava and a winding CS branch. However, utilizing readily available tools, such as the coronary balloon and Guide Plus II ST catheter, proved instrumental in overcoming these obstacles. As a result, LOT-CRT provided the patient with a safe alternative to surgical LV lead placement.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
CRT冠状窦导线置入的挑战:一种改良的“锚定球囊”技术。
一位有完全性心脏传导阻滞病史的80岁老人大约一年前接受了双腔起搏器植入术。他因起搏诱导的心肌病引起的新发性心力衰竭而返回医院;因此,我们计划将他的起搏器升级为双心室设备。最初的策略是用左束支区域起搏(LBBAP)结合冠状窦(CS)导线进行左束支区起搏优化心脏再同步治疗(LOT-CRT)。在这种具有挑战性的情况下,连接到左上腔静脉的大CS体和缠绕的CS分支的复杂组合阻碍了CS导线的成功放置。然而,使用现成的工具,如冠状动脉球囊和Guide Plus II ST段导管,被证明有助于克服这些障碍。因此,LOT-CRT为患者提供了手术左心室导线放置的安全替代方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Pace-Pacing and Clinical Electrophysiology
Pace-Pacing and Clinical Electrophysiology 医学-工程:生物医学
CiteScore
2.70
自引率
5.60%
发文量
209
审稿时长
2-4 weeks
期刊介绍: Pacing and Clinical Electrophysiology (PACE) is the foremost peer-reviewed journal in the field of pacing and implantable cardioversion defibrillation, publishing over 50% of all English language articles in its field, featuring original, review, and didactic papers, and case reports related to daily practice. Articles also include editorials, book reviews, Musings on humane topics relevant to medical practice, electrophysiology (EP) rounds, device rounds, and information concerning the quality of devices used in the practice of the specialty.
期刊最新文献
Coronary Spasm Due to Pulsed Field Ablation: A State-of-the-Art Review. Recalled But Responsive: Easier Extraction of Recalled Leads. Vein of Marshall Ethanol Infusion: Beware the Left Atrial Appendage Isolation. Changes in QRS morphology during antidromic atrioventricular reentrant tachycardia. Exercise-induced type 1 Brugada pattern in a child.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1