Experimental set-up to study power quality in single-phase split-phase distribution systems

I. Vicente, A. Arrinda, J. E. Rodriguez-Seco, L. Piyasinghe
{"title":"Experimental set-up to study power quality in single-phase split-phase distribution systems","authors":"I. Vicente, A. Arrinda, J. E. Rodriguez-Seco, L. Piyasinghe","doi":"10.24084/repqj21.251","DOIUrl":null,"url":null,"abstract":"Power Quality (PQ) has been an important topic since the creation of distribution systems. The deployment of the Advanced Metering Infrastructure (AMI) provided an important tool to measure the PQ of the electric power in the consumption points. One of the smallest secondary distribution systems in terms of power consumption is the single-phase split-phase system (120 V/240 V) that countries such as the United States, Canada, and some countries of central and south America have. Due to its size, this secondary distribution system is more prone to PQ issues. To that end, an experimental set-up was built by the authors so the distribution system from the Low Voltage (LV) transformer to the final appliances of the different houses was emulated. The aim is to capture the currents and voltages observed by the smart meter located at the entrance of the house and look for the different responses. A combination of real and dummy loads was installed in the set-up, so real noise could also be simulated. The set-up was totally automated by an industrial controller and relays, and it produced a very detailed dataset that could be used for multiple purposes.","PeriodicalId":21076,"journal":{"name":"Renewable Energy and Power Quality Journal","volume":"54 4","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Renewable Energy and Power Quality Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24084/repqj21.251","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Energy","Score":null,"Total":0}
引用次数: 0

Abstract

Power Quality (PQ) has been an important topic since the creation of distribution systems. The deployment of the Advanced Metering Infrastructure (AMI) provided an important tool to measure the PQ of the electric power in the consumption points. One of the smallest secondary distribution systems in terms of power consumption is the single-phase split-phase system (120 V/240 V) that countries such as the United States, Canada, and some countries of central and south America have. Due to its size, this secondary distribution system is more prone to PQ issues. To that end, an experimental set-up was built by the authors so the distribution system from the Low Voltage (LV) transformer to the final appliances of the different houses was emulated. The aim is to capture the currents and voltages observed by the smart meter located at the entrance of the house and look for the different responses. A combination of real and dummy loads was installed in the set-up, so real noise could also be simulated. The set-up was totally automated by an industrial controller and relays, and it produced a very detailed dataset that could be used for multiple purposes.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
研究单相分相配电系统电能质量的实验装置
自配电系统诞生以来,电能质量一直是一个重要的课题。先进计量基础设施(AMI)的部署为测量用电量点的PQ提供了重要工具。二次配电系统中功耗最小的一种是单相分相系统(120v / 240v),美国、加拿大和中美洲、南美洲的一些国家都采用这种系统。由于其规模,这种二次分配系统更容易出现PQ问题。为此,作者建立了一个实验装置,以模拟从低压变压器到不同房屋的最终电器的配电系统。目的是捕捉位于房屋入口处的智能电表所观察到的电流和电压,并寻找不同的响应。在装置中安装了真实和虚拟负载的组合,因此也可以模拟真实的噪声。该装置完全由工业控制器和继电器自动化,它产生了一个非常详细的数据集,可以用于多种目的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Renewable Energy and Power Quality Journal
Renewable Energy and Power Quality Journal Energy-Energy Engineering and Power Technology
CiteScore
0.70
自引率
0.00%
发文量
147
期刊最新文献
Experimental set-up to study power quality in single-phase split-phase distribution systems Analysis of Synthetic Inertia Applied to Wind Farms Cosine Windows in Interpolated DFT-based Method for an Accurate High-Frequency Distortion Assessment in Power Systems Thermal and electrical performance prediction of an FSPV system: a case study in the Douro/Portugal climatic conditions I-V Characteristics Measuring System for PV Generator based on PDM Inverter
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1