Removal Natural Organic Matter (NOM) in Peat Water from Wetland Area by Coagulation-Ultrafiltration Hybrid Process with Pretreatment Two-Stage Coagulation

M. Mahmud, Chairul Abdi, Badaruddin Mu’min
{"title":"Removal Natural Organic Matter (NOM) in Peat Water from Wetland Area by Coagulation-Ultrafiltration Hybrid Process with Pretreatment Two-Stage Coagulation","authors":"M. Mahmud, Chairul Abdi, Badaruddin Mu’min","doi":"10.20527/JWEM.V1I1.88","DOIUrl":null,"url":null,"abstract":"The primary problem encountered in the application of membrane technology was membrane fouling. During this time, hybrid process by coagulation-ultrafiltration in drinking water treatment that has been conducted by some research, using by one-stage coagulation. The goal of this research was to investigate the effect of two-stage coagulation as a pretreatment towards performance of the coagulation-ultrafiltration hybrid process for removal NOM in the peat water. Coagulation process, either with the one-stage or two-stage coagulation was very good in removing charge hydrophilic fraction, i.e. more than 98%. NOM fractions of the peat water, from the most easily removed by the two-stage coagulation and one-stage coagulation process was charged hydrophilic>strongly hydrophobic>weakly hydrophobic>neutral hydrophilic. The two-stage coagulation process could removed UV 254 and colors with a little better than the one-stage coagulation at the optimum coagulant dose. Neutral hydrophilic fraction of peat water NOM was the most influential fraction of UF membrane fouling. The two-stage coagulation process better in removing the neutral hidrophilic fraction, while removing of the charged hydrophilic, strongly hydrophobic and weakly hydrophobic similar to the one-stage coagulation. Hybrid process by pretreatment with two-stage coagulation, beside can increased removal efficiency of UV 254 and color, also can reduced fouling rate of the ultrafiltration membraneIt must not exceed 250 words, contains a brief summary of the text, covering the whole manuscript without being too elaborate on every section. Avoid any abbreviation, unless it is a common knowledge or has been previously stated.","PeriodicalId":30661,"journal":{"name":"Journal of Wetlands Environmental Management","volume":"193 ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2016-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Wetlands Environmental Management","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20527/JWEM.V1I1.88","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

Abstract

The primary problem encountered in the application of membrane technology was membrane fouling. During this time, hybrid process by coagulation-ultrafiltration in drinking water treatment that has been conducted by some research, using by one-stage coagulation. The goal of this research was to investigate the effect of two-stage coagulation as a pretreatment towards performance of the coagulation-ultrafiltration hybrid process for removal NOM in the peat water. Coagulation process, either with the one-stage or two-stage coagulation was very good in removing charge hydrophilic fraction, i.e. more than 98%. NOM fractions of the peat water, from the most easily removed by the two-stage coagulation and one-stage coagulation process was charged hydrophilic>strongly hydrophobic>weakly hydrophobic>neutral hydrophilic. The two-stage coagulation process could removed UV 254 and colors with a little better than the one-stage coagulation at the optimum coagulant dose. Neutral hydrophilic fraction of peat water NOM was the most influential fraction of UF membrane fouling. The two-stage coagulation process better in removing the neutral hidrophilic fraction, while removing of the charged hydrophilic, strongly hydrophobic and weakly hydrophobic similar to the one-stage coagulation. Hybrid process by pretreatment with two-stage coagulation, beside can increased removal efficiency of UV 254 and color, also can reduced fouling rate of the ultrafiltration membraneIt must not exceed 250 words, contains a brief summary of the text, covering the whole manuscript without being too elaborate on every section. Avoid any abbreviation, unless it is a common knowledge or has been previously stated.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
混凝-超滤混合预处理两段混凝法去除湿地泥炭水中的天然有机物(NOM
膜技术应用中遇到的主要问题是膜污染。在此期间,混凝-超滤混合工艺在饮用水处理中进行了一些研究,采用的是一级混凝法。本研究的目的是研究两级混凝预处理对混凝-超滤混合工艺去除泥炭水中NOM性能的影响。混凝工艺,无论是一级混凝还是二级混凝,对电荷亲水组分的去除率都很好,均在98%以上。泥炭水的NOM馏分,从最易去除的两段混凝和一段混凝工艺分别为带电亲水性>强疏水性>弱疏水性>中性亲水性。在最佳混凝剂用量下,两段混凝法对UV - 254的去除效果略优于一段混凝法。泥炭水NOM的中性亲水组分是对超滤膜污染影响最大的组分。两段混凝工艺在去除中性亲水性组分方面效果较好,而去除带电亲水性、强疏水性和弱疏水性类似于一段混凝。采用两段混凝预处理的混合工艺,除了能提高UV - 254和颜色的去除效率外,还能降低超滤膜的污染率。它不应超过250字,包含简短的文字摘要,涵盖整个稿件,而不必过于详细。避免任何缩写,除非它是一个常识或以前已经说明过。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
8
期刊最新文献
Swot Analysis of Peatland Utilization Assessment for Community (Case Study at Banjar Regency of South Kalimantan) Remote Sensing-Based Assessment of How Much Tropical Wetland Fires Contribute to Carbon Emissions and How Fast the Carbon Recovering Is The Study of Superior Varieties and New Plant Types of Rice on Various Organic Cropping Systems in Tidal Land Phenotype Characteristics of Alabio Ducks (Anas Platyrhynchos Borneo) in South Kalimantan The Value of Mangrove Ecosystems Based on Mangrove Carbon Sequestration in West Kalimantan
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1