{"title":"Impact of Plaque Erosion on Stress/Strain and Flow Shear Stress Calculation: An OCT-Based FSI Modeling Study","authors":"Liang Wang, H. Jia, Luping He, R. Lv, Xiaoya Guo, Chun Yang, D. Giddens, H. Samady, A. Maehara, G. Mintz, D. Tang","doi":"10.32604/mcb.2019.07522","DOIUrl":null,"url":null,"abstract":"Plaque erosion, one of the primary causes for coronary thrombosis, is responsible for about one third of the patients with acute coronary syndrome (ACS) [1]. Histological studies characterized the eroded plaque as a plaque with following morphological features: 1) plaque intima having direct contact with intraluminal thrombus due to the absence of endothelium or endothelial injury; 2) without rupture in the fibrous cap; 3) abundance of proteoglycans and smooth muscle cells on the luminal surface under the thrombus [2]. These characteristics has been applied in in vivo diagnosis of plaque erosion using  optical coherence tomography (OCT) image technology and specific treatment strategy has also been developed for plaque erosion related ACS [3]. However, The pathogenesis mechanisms that cause plaque erosion are not fully understood [2]. It is postulated that plaque erosion has close association with biomechanical conditions in the coronary vessel [2]. In this work, a patient-specific OCT-based modeling approach was develop 3D fluid-structure interaction (FSI) models to investigate the biomechanical conditions in eroded plaque and investigate the impact of erosion-induced inflammation on plaque stress/strain conditions. \nPatient-specific OCT data of eroded coronary plaque were acquired from one male patient (age: 64) with frequency-domain OCT C7XR system and the Dragon Fly catheter (Lightlab Imaging/St. Jude Medical). Erosion sites were identified as the luminal surface having direct contact with intraluminal thrombus on the OCT images. Biplane X-ray angiographic data (Allura Xper FD10 System, Philips, Bothel, WA)  were also acquired with the information of the location of the coronary artery stenosis and vessel curvature. OCT images were segmented manually with external elastic membrane (EEM) contour assumed to have positive remodeling ratio 1.1 for this plaque. The trailing edge of the lipid-rich necrotic core (lipid) was also assumed since it cannot be seen on the OCT images.  Co-registration of OCT and angiographic data were performed to reconstruct the 3D coronary geometry. Our FSI modeling procedures with pre-shrink–stretch process and anisotropic material properties were previously developed. Blood flow was assumed to be laminar, Newtonian and incompressible, with arbitrary Lagrangian–Eulerian formulation of the Navier–Stokes equations used as the governing equations. The governing equations of the structure models included equations of motion, the nonlinear Cauchy–Green strain–displacement relation and Mooney–Rivlin material properties. To reflect tissue weakening caused by erosion-induced inflammation, the material stiffness of plaque intima at the erosion site was adjust to one tenth of un-eroded fibrous plaque tissue [2]. Three FSI models were constructed to investigate the impacts of erosion-induced inflammation and lipid component on plaque stress/strain conditions: M1, without erosion (this means plaque intima at the erosion sites were not softened)  and without inclusion of lipid component; M2, with erosion but no lipid component; M3, with erosion and inclusion of lipid component. Pulsating pressure conditions were prescribed at the inlet and outlet of the vessel segment. Fluid–structure interaction boundary conditions including force balance and no-slip conditions were imposed to the fluid–structure interface between blood flow and vessel lumen surface. Results for plaque wall stress/strain (PWS/PWSn) and flow wall shear stress (WSS) from the FSI models corresponding to peak blood pressure were extracted for analysis. \nTable 1 summarizes the average values of the biomechanical factors both at erosion sites and fibrous cap overlaying lipid component for 3 models. By comparing M1 and M2 at the erosion sites, Mean PWS value decreases from 49.98 kPa to 18.83 kPa (62.32% decrease) while Mean PWSn value increases from 0.1231 to 0.1384 (12% increase) as the material stiffness becomes 10 times soft. At the fibrous cap, M3 (with inclusion of lipid) will elevates mean PWS and PWSn values by 48.59% and 16.09%, respectively. The impacts of erosion and lipid on flow shear stress were limited (<2%). \nTable 1: Average values of three biomechanical factors over erosion sites and fibrous cap overlaying lipid core.  \n \n \n \n \nAverage values of biomechanical factors over Erosion sites for 3 Models \n \n \n \n \n  \n \n \nM1 \n \n \nM2 \n \n \nM3 \n \n \n \n \nMean PWS (kPa) \n \n \n49.9759 \n \n \n18.8318 \n \n \n18.8298 \n \n \n \n \nMean PWSn \n \n \n0.1231 \n \n \n0.1384 \n \n \n0.1384 \n \n \n \n \nMean WSS (dyn/cm2) \n \n \n101.0637 \n \n \n99.9383 \n \n \n99.4303 \n \n \n \n \nAverage values of biomechanical factors over fibrous cap overlaying lipid for 3 Models \n \n \n \n \n  \n \n \nM1 \n \n \nM2 \n \n \nM3 \n \n \n \n \nMean PWS (kPa) \n \n \n68.3209 \n \n \n68.3199 \n \n \n101.5173 \n \n \n \n \nMean PWSn \n \n \n0.0870 \n \n \n0.0870 \n \n \n0.1010 \n \n \n \n \nMean WSS (dyn/cm2) \n \n \n18.5260 \n \n \n18.4634 \n \n \n18.1910 \n \n \n \n \nTo conclude, erosion-induced inflammation on blood vessel would lead to lower stress distribution but larger strain distribution, while lipid component would elevate both stress and strain conditions. This shows the influence of erosion and lipid component has impacts on stress/strain calculations which are closely related to plaque assessment.","PeriodicalId":48719,"journal":{"name":"Molecular & Cellular Biomechanics","volume":"25 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Molecular & Cellular Biomechanics","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.32604/mcb.2019.07522","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Biochemistry, Genetics and Molecular Biology","Score":null,"Total":0}
引用次数: 0

Abstract

Plaque erosion, one of the primary causes for coronary thrombosis, is responsible for about one third of the patients with acute coronary syndrome (ACS) [1]. Histological studies characterized the eroded plaque as a plaque with following morphological features: 1) plaque intima having direct contact with intraluminal thrombus due to the absence of endothelium or endothelial injury; 2) without rupture in the fibrous cap; 3) abundance of proteoglycans and smooth muscle cells on the luminal surface under the thrombus [2]. These characteristics has been applied in in vivo diagnosis of plaque erosion using  optical coherence tomography (OCT) image technology and specific treatment strategy has also been developed for plaque erosion related ACS [3]. However, The pathogenesis mechanisms that cause plaque erosion are not fully understood [2]. It is postulated that plaque erosion has close association with biomechanical conditions in the coronary vessel [2]. In this work, a patient-specific OCT-based modeling approach was develop 3D fluid-structure interaction (FSI) models to investigate the biomechanical conditions in eroded plaque and investigate the impact of erosion-induced inflammation on plaque stress/strain conditions. Patient-specific OCT data of eroded coronary plaque were acquired from one male patient (age: 64) with frequency-domain OCT C7XR system and the Dragon Fly catheter (Lightlab Imaging/St. Jude Medical). Erosion sites were identified as the luminal surface having direct contact with intraluminal thrombus on the OCT images. Biplane X-ray angiographic data (Allura Xper FD10 System, Philips, Bothel, WA)  were also acquired with the information of the location of the coronary artery stenosis and vessel curvature. OCT images were segmented manually with external elastic membrane (EEM) contour assumed to have positive remodeling ratio 1.1 for this plaque. The trailing edge of the lipid-rich necrotic core (lipid) was also assumed since it cannot be seen on the OCT images.  Co-registration of OCT and angiographic data were performed to reconstruct the 3D coronary geometry. Our FSI modeling procedures with pre-shrink–stretch process and anisotropic material properties were previously developed. Blood flow was assumed to be laminar, Newtonian and incompressible, with arbitrary Lagrangian–Eulerian formulation of the Navier–Stokes equations used as the governing equations. The governing equations of the structure models included equations of motion, the nonlinear Cauchy–Green strain–displacement relation and Mooney–Rivlin material properties. To reflect tissue weakening caused by erosion-induced inflammation, the material stiffness of plaque intima at the erosion site was adjust to one tenth of un-eroded fibrous plaque tissue [2]. Three FSI models were constructed to investigate the impacts of erosion-induced inflammation and lipid component on plaque stress/strain conditions: M1, without erosion (this means plaque intima at the erosion sites were not softened)  and without inclusion of lipid component; M2, with erosion but no lipid component; M3, with erosion and inclusion of lipid component. Pulsating pressure conditions were prescribed at the inlet and outlet of the vessel segment. Fluid–structure interaction boundary conditions including force balance and no-slip conditions were imposed to the fluid–structure interface between blood flow and vessel lumen surface. Results for plaque wall stress/strain (PWS/PWSn) and flow wall shear stress (WSS) from the FSI models corresponding to peak blood pressure were extracted for analysis. Table 1 summarizes the average values of the biomechanical factors both at erosion sites and fibrous cap overlaying lipid component for 3 models. By comparing M1 and M2 at the erosion sites, Mean PWS value decreases from 49.98 kPa to 18.83 kPa (62.32% decrease) while Mean PWSn value increases from 0.1231 to 0.1384 (12% increase) as the material stiffness becomes 10 times soft. At the fibrous cap, M3 (with inclusion of lipid) will elevates mean PWS and PWSn values by 48.59% and 16.09%, respectively. The impacts of erosion and lipid on flow shear stress were limited (<2%). Table 1: Average values of three biomechanical factors over erosion sites and fibrous cap overlaying lipid core.  Average values of biomechanical factors over Erosion sites for 3 Models   M1 M2 M3 Mean PWS (kPa) 49.9759 18.8318 18.8298 Mean PWSn 0.1231 0.1384 0.1384 Mean WSS (dyn/cm2) 101.0637 99.9383 99.4303 Average values of biomechanical factors over fibrous cap overlaying lipid for 3 Models   M1 M2 M3 Mean PWS (kPa) 68.3209 68.3199 101.5173 Mean PWSn 0.0870 0.0870 0.1010 Mean WSS (dyn/cm2) 18.5260 18.4634 18.1910 To conclude, erosion-induced inflammation on blood vessel would lead to lower stress distribution but larger strain distribution, while lipid component would elevate both stress and strain conditions. This shows the influence of erosion and lipid component has impacts on stress/strain calculations which are closely related to plaque assessment.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
斑块侵蚀对应力/应变和流动剪切应力计算的影响:基于oct的FSI模型研究
这表明侵蚀和脂质成分的影响对与斑块评估密切相关的应力/应变计算有影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Molecular & Cellular Biomechanics
Molecular & Cellular Biomechanics CELL BIOLOGYENGINEERING, BIOMEDICAL&-ENGINEERING, BIOMEDICAL
CiteScore
1.70
自引率
0.00%
发文量
21
期刊介绍: The field of biomechanics concerns with motion, deformation, and forces in biological systems. With the explosive progress in molecular biology, genomic engineering, bioimaging, and nanotechnology, there will be an ever-increasing generation of knowledge and information concerning the mechanobiology of genes, proteins, cells, tissues, and organs. Such information will bring new diagnostic tools, new therapeutic approaches, and new knowledge on ourselves and our interactions with our environment. It becomes apparent that biomechanics focusing on molecules, cells as well as tissues and organs is an important aspect of modern biomedical sciences. The aims of this journal are to facilitate the studies of the mechanics of biomolecules (including proteins, genes, cytoskeletons, etc.), cells (and their interactions with extracellular matrix), tissues and organs, the development of relevant advanced mathematical methods, and the discovery of biological secrets. As science concerns only with relative truth, we seek ideas that are state-of-the-art, which may be controversial, but stimulate and promote new ideas, new techniques, and new applications.
期刊最新文献
Hot Topics of Molecular and Cellular Biomechanics in 2022 CFD Study on Hemodynamic Characteristics of Inferior Vena Cava Filter Affected by Blood Vessel Diameter Can PAPE-Induced Increases in Jump Height Be Explained by Jumping Kinematics? Reconstruction of the Hindlimb Locomotion of Confuciusornis (Aves) and Its Implication for the Origin of Avian Flight Classification of Leukemia and Leukemoid Using VGG-16 Convolutional Neural Network Architecture
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1