DEFINITION OF EFFICIENCY OF POLYMETHYLPHENYLSІLOXANE-BASED FIRE PROTECTIVE COATINGS FOR STEEL BUILDING STRUCTURES

O. Pazen, S. Vovk, O. Bashynskyi, M. Peleshko
{"title":"DEFINITION OF EFFICIENCY OF POLYMETHYLPHENYLSІLOXANE-BASED FIRE PROTECTIVE COATINGS FOR STEEL BUILDING STRUCTURES","authors":"O. Pazen, S. Vovk, O. Bashynskyi, M. Peleshko","doi":"10.32447/20786662.32.2018.08","DOIUrl":null,"url":null,"abstract":"The article deals with the current problem of determining the fire resistance of protected steel elements of building structures. Based on the analysis of literary sources, the main methods for increasing the fire resistance of steel structures are considered, as well as the use of fire retardant coatings based on polymetallophenylsiloxane. Analytical studies were conducted to determine the time of fire protection of the coating, compared to unprotected structures. The results show that the limit of fire resistance of protected steel constructions is increased 2-4 times, depending on the thickness of the application.","PeriodicalId":12280,"journal":{"name":"Fire Safety","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-08-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fire Safety","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32447/20786662.32.2018.08","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The article deals with the current problem of determining the fire resistance of protected steel elements of building structures. Based on the analysis of literary sources, the main methods for increasing the fire resistance of steel structures are considered, as well as the use of fire retardant coatings based on polymetallophenylsiloxane. Analytical studies were conducted to determine the time of fire protection of the coating, compared to unprotected structures. The results show that the limit of fire resistance of protected steel constructions is increased 2-4 times, depending on the thickness of the application.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
polymethylphenylsІloxane-based钢结构防火涂料效能的定义
本文论述了目前建筑结构防护钢构件耐火性能的确定问题。在对文献资料进行分析的基础上,提出了提高钢结构耐火性能的主要方法,以及基于聚金属苯硅氧烷的防火涂料的使用。进行了分析研究,以确定涂层的防火时间,与未保护的结构进行比较。结果表明,防护钢结构的耐火极限随应用厚度的不同而提高2 ~ 4倍。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
АНАЛІЗ ОБЛАДНАННЯ ДЛЯ ГАСІННЯ ЕЛЕКТРОМОБІЛІВ ТА РОЗРОБКА РЕКОМЕНДАЦІЙ З ЇХ ГАСІННЯ АНАЛІЗ ДОСВІДУ ВИКОРИСТАННЯ МОДИФІКУВАЛЬНИХ ДОБАВОК ТА ЇХ ФІЗИКО-ХІМІЧНИХ ВЛАСТИВОСТЕЙ ДЛЯ ПОДАЛЬШОГО ЗАСТОСУВАННЯ У СКЛАДІ КОМПРЕСІЙНОЇ ПІНИ РОЗРОБЛЕННЯ ТА ЗАСТОСУВАННЯ ВІТЧИЗНЯНОЇ НОРМАТИВНОЇ БАЗИ ЩОДО ОЦІНЮВАННЯ ЯКОСТІ ПІНОУТВОРЮВАЧІВ ДЛЯ ГАСІННЯ ПОЖЕЖ НА ПЕРЕХІДНИЙ ПЕРІОД ІМІТАЦІЙНА МОДЕЛЬ ПРОЦЕСУ ВИЗНАЧЕННЯ ЧАСОВИХ ПАРАМЕТРІВ ПОЖЕЖНОГО СПОВІЩУВАЧА УДОСКОНАЛЕННЯ АНАЛІТИЧНОЇ ОЦІНКИ ТЕМПЕРАТУР ЗАЙМАННЯ РІДИН
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1