Analysis of Z-source inverter control system for asynchronous drive for gas compressor

D. Ivanchenko, R. Salov, E. V. Yakovleva
{"title":"Analysis of Z-source inverter control system for asynchronous drive for gas compressor","authors":"D. Ivanchenko, R. Salov, E. V. Yakovleva","doi":"10.1109/EICONRUS.2018.8317177","DOIUrl":null,"url":null,"abstract":"The article deals with the comparison of Z-source inverter based control systems for the asynchronous drive of gas compressor that is used in oil and gas industry. The relevance of the task is highlighted by the fact that choice of control system determines the reliability and the efficiency of gas system drive. Two types of indirect DC-link voltage control techniques were examined in order to estimate operation effectiveness of control system in dynamic modes. For that purpose simulation model of ZSI fed by induction motor, based on state space averaged modeling method, has been developed utilizing MATLAB/Simulink environment. The simulation results of dynamic performance of the ZSI with single-loop and dual-loop capacitor voltage control techniques during input voltage changes and steady state operations are presented and analyzed.","PeriodicalId":6562,"journal":{"name":"2018 IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering (EIConRus)","volume":"37 1","pages":"636-640"},"PeriodicalIF":0.0000,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering (EIConRus)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EICONRUS.2018.8317177","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

The article deals with the comparison of Z-source inverter based control systems for the asynchronous drive of gas compressor that is used in oil and gas industry. The relevance of the task is highlighted by the fact that choice of control system determines the reliability and the efficiency of gas system drive. Two types of indirect DC-link voltage control techniques were examined in order to estimate operation effectiveness of control system in dynamic modes. For that purpose simulation model of ZSI fed by induction motor, based on state space averaged modeling method, has been developed utilizing MATLAB/Simulink environment. The simulation results of dynamic performance of the ZSI with single-loop and dual-loop capacitor voltage control techniques during input voltage changes and steady state operations are presented and analyzed.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
气体压缩机异步驱动z源逆变控制系统分析
本文介绍了几种基于z源逆变器的控制系统在石油天然气工业用气体压缩机异步驱动中的比较。控制系统的选择决定了燃气系统驱动的可靠性和效率,这一事实凸显了该任务的相关性。为了评估控制系统在动态模式下的运行有效性,研究了两种间接直流链路电压控制技术。为此,利用MATLAB/Simulink环境,基于状态空间平均建模方法,建立了感应电机驱动ZSI的仿真模型。给出并分析了采用单环和双环电容电压控制技术的ZSI在输入电压变化和稳态工作时的动态性能仿真结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The modeling of emergency oil spills in GIS Load balancing in cloud computing Practical characterisation of the piezo electric properties of a 3K T300 carbon fibre for impact sensoring Modelling of a photovoltaic array using Analog System Lab Kit Pro board Design of optimum configuration of a hybrid power system for Abertay University campus
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1