J. Baek, Jaewon Choi, Yeonho Jeong, Yujin Jang, G. Moon, Chanhun Yu
{"title":"Asymmetrical half-bridge converter with reduced DC-offset current in transformer","authors":"J. Baek, Jaewon Choi, Yeonho Jeong, Yujin Jang, G. Moon, Chanhun Yu","doi":"10.1109/IPEMC.2016.7512648","DOIUrl":null,"url":null,"abstract":"In this paper, a new asymmetrical half-bridge converter with reduced DC-offset current in transformer is proposed. In general, to meet the hold-up time conditions, the conventional asymmetrical half-bridge (AHB) converter operates in wide-input-voltage range. Wide-input-voltage range design makes converter suffered from severe asymmetric operation under the nominal operation, which increases the DC-offset current in the transformer, size of the transformer, and unbalance of the voltage stresses of the secondary rectifiers. On the other hand, the proposed converter can reduce the DC-offset current in the transformer and relieve the unbalanced voltage stresses of the secondary rectifiers under the nominal operation by changing transformer turns-ratio with an auxiliary switch and capacitor. Therefore, the proposed converter can achieve high efficiency. The validity of the proposed converter is confirmed by experimental results from a prototype with 330-400V input, 300W/12V output.","PeriodicalId":6857,"journal":{"name":"2016 IEEE 8th International Power Electronics and Motion Control Conference (IPEMC-ECCE Asia)","volume":"112 1","pages":"2249-2253"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE 8th International Power Electronics and Motion Control Conference (IPEMC-ECCE Asia)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPEMC.2016.7512648","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
In this paper, a new asymmetrical half-bridge converter with reduced DC-offset current in transformer is proposed. In general, to meet the hold-up time conditions, the conventional asymmetrical half-bridge (AHB) converter operates in wide-input-voltage range. Wide-input-voltage range design makes converter suffered from severe asymmetric operation under the nominal operation, which increases the DC-offset current in the transformer, size of the transformer, and unbalance of the voltage stresses of the secondary rectifiers. On the other hand, the proposed converter can reduce the DC-offset current in the transformer and relieve the unbalanced voltage stresses of the secondary rectifiers under the nominal operation by changing transformer turns-ratio with an auxiliary switch and capacitor. Therefore, the proposed converter can achieve high efficiency. The validity of the proposed converter is confirmed by experimental results from a prototype with 330-400V input, 300W/12V output.