The use of three-dimensional navigation and advanced intraoperative imaging in minimally invasive pelvic and acetabular fracture fixation: A systematic review

B. Bosakhar, L. Nairn, Kathy Liu, Julien Chapleau, Dale Williams, H. Johal
{"title":"The use of three-dimensional navigation and advanced intraoperative imaging in minimally invasive pelvic and acetabular fracture fixation: A systematic review","authors":"B. Bosakhar, L. Nairn, Kathy Liu, Julien Chapleau, Dale Williams, H. Johal","doi":"10.1177/22104917231191806","DOIUrl":null,"url":null,"abstract":"Pelvic and acetabular fractures are challenging injuries to treat. This review evaluates three-dimensional intraoperative imaging and navigation-guided percutaneous SI, trans-iliac, trans-sacral, and acetabular screw placement versus conventional methods performed with C-arm imaging. A systematic search of MEDLINE, Embase, and Cochrane was performed. Two reviewers independently extracted data into a collaborative data form designed a priori and piloted prior to its use. Descriptive statistics are presented where applicable. Summary statistics analysis was presented based on the fracture type. Continuous data such as fluoroscopic and operative time were compared with unpaired Student t-test and pooled data of revision rate and complications were compared with chi-square analysis with an alpha set at 0.05. The rate of complications using conventional fluoroscopy was 11.3% (26/230) compared to three-dimensional navigation (6.7% (40/597), X2 (DF: 1, N = 827) = 4.79, p = .028.) which translated to a higher rate of revision surgeries in the conventional fluoroscopy group (10.9% vs. 0.8%) X2 (DF: 1, N = 827) = 47.8, p ≤.001. Average fluoroscopic time was lower for studies using three-dimensional navigation (28.8 ± 14.3 s, n = 71) compared to conventional fluoroscopy (57.8 ± 4.2 s, n = 38, p ≤.001). Three-dimensional navigation during minimally invasive pelvis and acetabular fracture fixation may have some benefits. Level of evidence: IV.","PeriodicalId":42408,"journal":{"name":"Journal of Orthopaedics Trauma and Rehabilitation","volume":"1 1","pages":""},"PeriodicalIF":0.4000,"publicationDate":"2023-08-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedics Trauma and Rehabilitation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/22104917231191806","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Pelvic and acetabular fractures are challenging injuries to treat. This review evaluates three-dimensional intraoperative imaging and navigation-guided percutaneous SI, trans-iliac, trans-sacral, and acetabular screw placement versus conventional methods performed with C-arm imaging. A systematic search of MEDLINE, Embase, and Cochrane was performed. Two reviewers independently extracted data into a collaborative data form designed a priori and piloted prior to its use. Descriptive statistics are presented where applicable. Summary statistics analysis was presented based on the fracture type. Continuous data such as fluoroscopic and operative time were compared with unpaired Student t-test and pooled data of revision rate and complications were compared with chi-square analysis with an alpha set at 0.05. The rate of complications using conventional fluoroscopy was 11.3% (26/230) compared to three-dimensional navigation (6.7% (40/597), X2 (DF: 1, N = 827) = 4.79, p = .028.) which translated to a higher rate of revision surgeries in the conventional fluoroscopy group (10.9% vs. 0.8%) X2 (DF: 1, N = 827) = 47.8, p ≤.001. Average fluoroscopic time was lower for studies using three-dimensional navigation (28.8 ± 14.3 s, n = 71) compared to conventional fluoroscopy (57.8 ± 4.2 s, n = 38, p ≤.001). Three-dimensional navigation during minimally invasive pelvis and acetabular fracture fixation may have some benefits. Level of evidence: IV.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
三维导航和先进术中成像在微创骨盆和髋臼骨折固定中的应用:系统回顾
骨盆和髋臼骨折是具有挑战性的损伤治疗。本文综述了术中三维成像和导航引导下经皮SI、经髂、经骶骨和髋臼螺钉置入与常规c臂成像方法的比较。对MEDLINE、Embase和Cochrane进行系统检索。两名审稿人独立地将数据提取到一个预先设计并在使用之前进行试点的协作数据表单中。在适用的情况下提供描述性统计。根据骨折类型进行汇总统计分析。透视和手术时间等连续资料采用unpaired Student t检验比较,翻修率和并发症合并资料采用卡方分析比较,alpha集为0.05。常规透视组的并发症发生率为11.3%(26/230),而三维导航组为6.7% (40/597),X2 (DF: 1, N = 827) = 4.79, p = 0.028 .这意味着常规透视组的翻修手术率更高(10.9% vs. 0.8%) X2 (DF: 1, N = 827) = 47.8, p≤0.001。三维导航研究的平均透视时间(28.8±14.3 s, n = 71)低于常规透视(57.8±4.2 s, n = 38, p≤0.001)。三维导航在微创骨盆和髋臼骨折固定中可能有一定的好处。证据等级:四级。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.60
自引率
0.00%
发文量
36
审稿时长
8 weeks
期刊最新文献
Ultrasonic measurement for the diagnosis of cubital tunnel syndrome: A study in the Hong Kong Chinese population The surgical outcome of postoperative radial neck nonunion: Retrospective case series with systematic review Tip-to-apex distance does not predict fixation failure regardless of reduction quality in intra-capsular neck of femur fractures treated with femoral neck system Real world patient-reported and health care professional-perceived pain severity in outpatient fracture clinic procedures Impact of COVID-19 pandemic on sports and arthroscopic surgery in local hospitals
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1