{"title":"Audit Energi Pemakaian Air Conditioning (AC) Di Gedung Dinas Pekerjaan Umum Kab. Ketapang Propinsi Kalimantan Barat","authors":"A. Lukman","doi":"10.26418/ELKHA.V10I1.25202","DOIUrl":null,"url":null,"abstract":"Abstract–Goverment Building Pekerjaan Umum Office of Ketapang District, West Kalimantan is one of government office buildings into categorized  of office buildings that use air conditioning. To implement one of the government's policy that is to save electricity energy consumption in government building, it must be known Intensity of Energy Consumption in the building, Preliminary Energy Audit Result in Public Service Office Building of Kab. Ketapang shows the value of Energy Consumption Intensity (IKE) of 198.13 kWH / (m ^ 2.year) and belongs to the category of government building with air conditioning with energy efficient enough.To improve the category of energy saving savings, a Detailed Energy Audit should be performed. Detailed Energy Audit Result, through the measurement data analysis step, the search for energy saving opportunities analysis of energy saving opportunities resulted some recommendations that must be done by the Office of Public Works of Kab. Ketapang in order to improve the category of energy-efficient usage. The results of the Detailed Energy Audit improve the category of energy use in Public Works Office to be efficient with the value of Energy Consumption Intensity (IKE) 156.83 kWH / (m2.year)And savings programs that are made include in energy savings program at no cost and with low cost.","PeriodicalId":32754,"journal":{"name":"Elkha Jurnal Teknik Elektro","volume":"13 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-03-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Elkha Jurnal Teknik Elektro","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26418/ELKHA.V10I1.25202","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Abstract–Goverment Building Pekerjaan Umum Office of Ketapang District, West Kalimantan is one of government office buildings into categorized  of office buildings that use air conditioning. To implement one of the government's policy that is to save electricity energy consumption in government building, it must be known Intensity of Energy Consumption in the building, Preliminary Energy Audit Result in Public Service Office Building of Kab. Ketapang shows the value of Energy Consumption Intensity (IKE) of 198.13 kWH / (m ^ 2.year) and belongs to the category of government building with air conditioning with energy efficient enough.To improve the category of energy saving savings, a Detailed Energy Audit should be performed. Detailed Energy Audit Result, through the measurement data analysis step, the search for energy saving opportunities analysis of energy saving opportunities resulted some recommendations that must be done by the Office of Public Works of Kab. Ketapang in order to improve the category of energy-efficient usage. The results of the Detailed Energy Audit improve the category of energy use in Public Works Office to be efficient with the value of Energy Consumption Intensity (IKE) 156.83 kWH / (m2.year)And savings programs that are made include in energy savings program at no cost and with low cost.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
公共工程部工作大楼对空调使用能源的审计。西婆罗洲省的海螺
西加里曼丹吉打邦区Pekerjaan Umum办公室是政府办公楼中使用空调的办公楼之一。为了贯彻政府建筑节能的政策之一,必须了解建筑能耗强度,Kab公共服务办公楼能源审计初步结果。Ketapang的能耗强度(IKE)值为198.13 kWH / (m ^ 2.year),属于空调节能程度足够的政府建筑类别。为了改善节能的类别,应该进行详细的能源审计。详细的能源审计结果,通过测量数据分析步骤,寻找节能机会,对节能机会进行分析,得出了一些必须由Kab公共工程办公室完成的建议。以提高吉打邦类的节能利用率。详细的能源审计结果提高了公共工程办公室的能源使用类别,能源消耗强度(IKE)值为156.83 kWH / (m2.year),并制定了节能方案,包括无成本和低成本的节能方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
23
审稿时长
10 weeks
期刊最新文献
Multi-oscillations Detection for Process Variables Based on K-Nearest Neighbor Interference Analysis Between 5G System and Fixed Satellite Service in the 28 GHz Band Heading control for quadruped stair climbing based on PD controller for the KRSRI competition Optimization Objective Function Corona Discharge Acoustic Using Fuzzy c-Means (FcM ) Temperature and Humidity Control System for Pole-Mounted Metering Circuit Breaker with Artificial Neural Network Methods
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1