Use of an x-ray beam-limiting cone to improve radiographic quality in diagnosis of traumatic reticuloperitonitis.

D. Pravettoni, D. Zani, M. Biggi, N. Morandi, M. Giancamillo, A. Bertagnoli, A. Belloli
{"title":"Use of an x-ray beam-limiting cone to improve radiographic quality in diagnosis of traumatic reticuloperitonitis.","authors":"D. Pravettoni, D. Zani, M. Biggi, N. Morandi, M. Giancamillo, A. Bertagnoli, A. Belloli","doi":"10.2376/0341-6593-116-429","DOIUrl":null,"url":null,"abstract":"To evaluate the quality and the diagnostic relevance of the radiographs of the reticular area obtained using an x-ray beam-limiting cone (LC), both conventional and LC images were analysed in 12 cows affected by traumatic reticuloperitonitis (TRP). The improvement in resolution, definition and contrast of the LC images and a clinical assessment of the diagnostic relevance of the procedure were scored. The use of LC improved the quality of the radiographs in 10 cases (83%) thanks to an improvement in the resolution (67%), definition (58%) and contrast (83%). The procedure was diagnostically relevant in 5 cases (42%), facilitating the detection of details not clearly visualised by previous conventional survey radiographs: a very thin foreign body responsible ofTRP, a mass in the ventro-caudal contour of the reticulum, the exact position of the foreign bodies. A consistency test for the x-rays was performed in a clinically healthy cow to confirm the improvement in the radiographic quality determined by the procedure. Although conventional imaging is often sufficient to confirm diagnosis ofTRP, the use of the LC improves the quality of reticular radiographs and in several cases can be fundamental for the identification of a thin foreign body or a lesion.","PeriodicalId":11154,"journal":{"name":"Deutsche tierarztliche Wochenschrift","volume":"1 1","pages":"429-435"},"PeriodicalIF":0.0000,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Deutsche tierarztliche Wochenschrift","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2376/0341-6593-116-429","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

To evaluate the quality and the diagnostic relevance of the radiographs of the reticular area obtained using an x-ray beam-limiting cone (LC), both conventional and LC images were analysed in 12 cows affected by traumatic reticuloperitonitis (TRP). The improvement in resolution, definition and contrast of the LC images and a clinical assessment of the diagnostic relevance of the procedure were scored. The use of LC improved the quality of the radiographs in 10 cases (83%) thanks to an improvement in the resolution (67%), definition (58%) and contrast (83%). The procedure was diagnostically relevant in 5 cases (42%), facilitating the detection of details not clearly visualised by previous conventional survey radiographs: a very thin foreign body responsible ofTRP, a mass in the ventro-caudal contour of the reticulum, the exact position of the foreign bodies. A consistency test for the x-rays was performed in a clinically healthy cow to confirm the improvement in the radiographic quality determined by the procedure. Although conventional imaging is often sufficient to confirm diagnosis ofTRP, the use of the LC improves the quality of reticular radiographs and in several cases can be fundamental for the identification of a thin foreign body or a lesion.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
应用x线限束锥提高外伤性网状腹膜炎的影像学诊断质量。
为了评估使用x射线束限制锥(LC)获得的网状区域x线片的质量和诊断相关性,分析了12头创伤性网状腹膜炎(TRP)的奶牛的常规和LC图像。改进的分辨率,清晰度和对比度的LC图像和临床评估的诊断相关性的程序进行评分。LC的使用提高了10例(83%)x线片的质量,这要归功于分辨率(67%)、清晰度(58%)和对比度(83%)的提高。在5例(42%)病例中,该程序与诊断相关,有助于发现以往常规x线片无法清晰显示的细节:造成trp的非常薄的异物,网状腹尾侧轮廓的肿块,异物的确切位置。对一头临床健康的奶牛进行了x射线一致性测试,以确认该程序确定的x射线质量的改善。虽然常规成像通常足以确诊trp,但LC的使用提高了网状x线片的质量,在一些情况下可以作为鉴别薄异物或病变的基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Use of an x-ray beam-limiting cone to improve radiographic quality in diagnosis of traumatic reticuloperitonitis. Risikoabschätzung von laMRSA in der Lebensmittelkette - Molekulare Diagnostik als Werkzeug zur Aufklärung epidemiologischer Zusammenhänge Zur Problematik der oralen Verabreichung von antimikrobiell wirksamen Substanzen Erfahrungen aus der Schweiz Eignung der Thermographie zur Erfassung von Entzündungen an den Gliedmassen von Mastschweinen Lungenabszess, Pleuraerguss und Aszites bei einem Rind mit Vena-cava-caudalis-Thrombose
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1