Characterization of cu free air ball constitutive behavior using microscale compression test

Sai Sudharsanan Paranjothy, Y. Singh, Allen Tippman, Hung-Yun Lin, G. Subbarayan, D. Jung, B. Sammakia
{"title":"Characterization of cu free air ball constitutive behavior using microscale compression test","authors":"Sai Sudharsanan Paranjothy, Y. Singh, Allen Tippman, Hung-Yun Lin, G. Subbarayan, D. Jung, B. Sammakia","doi":"10.1109/ITHERM.2014.6892303","DOIUrl":null,"url":null,"abstract":"In recent years, there is increasing interest in copper wirebond technology as an alternative to gold wirebond in microelectronic devices due to its superior electrical performance and low cost. At present, validated constitutive models for the strain rate and temperature dependent behavior of Cu free air ball (FAB) appear to be largely missing in the literature. The lack of reliable constitutive models for the Cu FAB has hampered the modeling of the wirebonding process and the ability to assess risk of fracture in ultra low-k dielectric stacks. The challenge to FAB characterization is primarily due to the difficulty in performing mechanical tests on spherical FAB of micrometers in size. To address this challenge, we perform compression tests on FAB using custom-built microscale tester in the current study. Specifically, the tester has three closed-loop controlled linear stages with submicron resolutions, a manual tilt stage, a six-axis load cell with sub-Newton load resolution for eliminating misalignment, a milliNewton resolution load cell, a capacitance sensor to estimate sample deformation and to control the vertical stage in closed loop, a high working depth camera for viewing the sample deformation, and controllers for the stages implemented in the LabVIEW environment. We compress the FAB between tungsten carbide punches and develop a constitutive model for the copper of FAB through an inverse modeling procedure. In the inverse procedure, the assumed constitutive model parameter values are iterated until the load-displacement response matches the experimentally observed response.","PeriodicalId":12453,"journal":{"name":"Fourteenth Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm)","volume":"55 1","pages":"365-368"},"PeriodicalIF":0.0000,"publicationDate":"2014-05-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fourteenth Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ITHERM.2014.6892303","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

In recent years, there is increasing interest in copper wirebond technology as an alternative to gold wirebond in microelectronic devices due to its superior electrical performance and low cost. At present, validated constitutive models for the strain rate and temperature dependent behavior of Cu free air ball (FAB) appear to be largely missing in the literature. The lack of reliable constitutive models for the Cu FAB has hampered the modeling of the wirebonding process and the ability to assess risk of fracture in ultra low-k dielectric stacks. The challenge to FAB characterization is primarily due to the difficulty in performing mechanical tests on spherical FAB of micrometers in size. To address this challenge, we perform compression tests on FAB using custom-built microscale tester in the current study. Specifically, the tester has three closed-loop controlled linear stages with submicron resolutions, a manual tilt stage, a six-axis load cell with sub-Newton load resolution for eliminating misalignment, a milliNewton resolution load cell, a capacitance sensor to estimate sample deformation and to control the vertical stage in closed loop, a high working depth camera for viewing the sample deformation, and controllers for the stages implemented in the LabVIEW environment. We compress the FAB between tungsten carbide punches and develop a constitutive model for the copper of FAB through an inverse modeling procedure. In the inverse procedure, the assumed constitutive model parameter values are iterated until the load-displacement response matches the experimentally observed response.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用微尺度压缩试验表征无铜空气球的本构行为
近年来,由于铜线键合技术具有优异的电性能和较低的成本,人们对其作为微电子器件中金线键合的替代品越来越感兴趣。目前,文献中缺乏有效的无Cu空气球(FAB)应变速率和温度依赖行为的本构模型。Cu FAB缺乏可靠的本构模型,这阻碍了对超低k介电层中线连接过程的建模和评估断裂风险的能力。FAB表征的挑战主要是由于难以对微米大小的球形FAB进行机械测试。为了解决这一挑战,我们在当前的研究中使用定制的微型测试器对FAB进行了压缩测试。具体来说,该测试仪具有三个亚微米分辨率的闭环控制线性级,一个手动倾斜级,一个具有亚牛顿负载分辨率的六轴称重传感器,用于消除不对准,一个千牛顿分辨率的称重传感器,一个电容传感器用于估计样品变形并在闭环中控制垂直级,一个高工作深度相机用于查看样品变形,以及在LabVIEW环境中实现的级控制器。我们将FAB压缩在碳化钨冲头之间,并通过反建模程序建立了FAB铜的本构模型。在反过程中,迭代假设的本构模型参数值,直到荷载-位移响应与实验观测响应相匹配。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Material behavior of SAC305 under high strain rate at high temperature Phase-separation of wetting fluids using nanoporous alumina membranes and micro-glass capillaries Nature-inspired enhanced microscale heat transfer in macro geometry Transient thermal imaging characterization of a die attached optoelectronic device on silicon A model for the free (top) surface deformation of through-silicon vias
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1