Pengaruh Suhu, Kelembaban Dan Kecepatan Angin Air Conditioner (AC) Terhadap Jumlah Angka Kuman Udara Ruangan

Daria Br Ginting, I. Santosa, Sri Indra Trigunarso
{"title":"Pengaruh Suhu, Kelembaban Dan Kecepatan Angin Air Conditioner (AC) Terhadap Jumlah Angka Kuman Udara Ruangan","authors":"Daria Br Ginting, I. Santosa, Sri Indra Trigunarso","doi":"10.26630/jak.v11i1.3183","DOIUrl":null,"url":null,"abstract":"A room that uses an Air Conditioner (AC) is one of the breeding grounds for air microorganisms, therefore it is necessary to have a number of germs in the room so as not to cause airborne disease. The purpose of this study was to determine the effect of temperature, humidity, and wind speed on the number of germs in an air-conditioned room. This type of research is an experimental consisting of 3 dependent variables and 1 independent variable with a cross-sectional research design. Laboratory room air samples were taken by the BRAB method, 12 times in a row. Sampling of the air using an air sampling pump. The results of the study showed that there was a fairly close relationship and a significant effect on temperature with the number of germs (p value = 0.005), with a temperature effect of 20.9%. There is a relationship and influence between humidity and germ numbers (p value = 0.000), with a humidity effect value of 31.9%. There is a relationship and influence between wind speed and germ numbers (p value = 0.009), with a wind speed effect of 18.5%. There is a simultaneous effect of temperature, humidity, and wind speed on the germ number of 33.6%.","PeriodicalId":17791,"journal":{"name":"Jurnal Media Analis Kesehatan","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Media Analis Kesehatan","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26630/jak.v11i1.3183","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

A room that uses an Air Conditioner (AC) is one of the breeding grounds for air microorganisms, therefore it is necessary to have a number of germs in the room so as not to cause airborne disease. The purpose of this study was to determine the effect of temperature, humidity, and wind speed on the number of germs in an air-conditioned room. This type of research is an experimental consisting of 3 dependent variables and 1 independent variable with a cross-sectional research design. Laboratory room air samples were taken by the BRAB method, 12 times in a row. Sampling of the air using an air sampling pump. The results of the study showed that there was a fairly close relationship and a significant effect on temperature with the number of germs (p value = 0.005), with a temperature effect of 20.9%. There is a relationship and influence between humidity and germ numbers (p value = 0.000), with a humidity effect value of 31.9%. There is a relationship and influence between wind speed and germ numbers (p value = 0.009), with a wind speed effect of 18.5%. There is a simultaneous effect of temperature, humidity, and wind speed on the germ number of 33.6%.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
温度、湿度和空调风速对室内微生物数量的影响
使用空调(AC)的房间是空气微生物的孳生地之一,因此房间内必须有一定数量的细菌,以免引起空气传播疾病。这项研究的目的是确定温度、湿度和风速对空调房间内细菌数量的影响。这类研究是由3个因变量和1个自变量组成的实验,采用横断面研究设计。采用BRAB法连续12次采集实验室空气样本。使用空气采样泵对空气进行采样。研究结果表明,温度与细菌数量有相当密切的关系,且对细菌数量有显著的影响(p值= 0.005),温度效应为20.9%。湿度与细菌数量之间存在相关关系和影响(p值= 0.000),湿度效应值为31.9%。风速与菌种数之间存在相关关系和影响(p值= 0.009),风速效应为18.5%。温度、湿度和风速对细菌数量的影响同时存在(33.6%)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
PENGARUH PEMBERIAN COOKIES DENGAN PENAMBAHAN TEPUNG TEMPE DAN KACANG MERAH TERHADAP PENINGKATAN BERAT BADAN BALITA GIZI KURANG STATUS GIZI ANAK SEKOLAH DI MI DARUSSALAM KOTA BENGKULU Pola Konsumsi Makanan Sumber Asam Lemak Trans pada mahasiswa PTS Kota Bengkulu di Era Pandemi Covid 19 Assessment of the Cytotoxic Effects of Dimethyl Sulfoxide (DMSO) on MCF-7 and HeLa Cell Line GAMBARAN AKTIVITAS ENZIM Aspartat aminotransferase (AST) PADA PEROKOK AKTIF 10-15 TAHUN DI WILAYAH KECAMATAN KAMPUNG MELAYU KOTA BENGKULU
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1