Power Plant Performance Analysis on Variations of Generator Loading at Ombilin Coal Fired Steam Power Plant Unit 1 (2x100 MW)

Ryan Adytia Putra, R. Nazir
{"title":"Power Plant Performance Analysis on Variations of Generator Loading at Ombilin Coal Fired Steam Power Plant Unit 1 (2x100 MW)","authors":"Ryan Adytia Putra, R. Nazir","doi":"10.25077/aijaset.v3i2.58","DOIUrl":null,"url":null,"abstract":"Abstract— Steam Power Plants are classified as thermal plants that convert chemical energy in fuel into electrical energy. In an effort to increase the effectiveness of the work of the plant, there needs to be proper planning for its operations, this is important because it directly affects the operational costs incurred by the plant. This journal aims to determine the effect of changes in load or variations in generator loading on power plant performance, both efficiency, heat rate and production costs of electricity generation and to identify the magnitude of the decline in the thermal performance of the generator, as well as determine the causes and parts of the plant whose performance level decreases compared to optimal conditions. The method used to calculate the efficiency and heat rate is the “Direct Method”, namely by directly comparing the input energy with the electrical output produced. The data used in this study is the “Power Plant Performance Test” data. The results of this study get the most optimal conditions when loading 93.39 MW Net with efficiency 34.693%, heat rate 2475,445 kcal/kWh and electricity production costs 413,297 Rp/kWh. The conclusion of this study is that plant performance is getting better at high loads.\nKeywords: Thermal efficiency, Heat Rate, Electricity Production Cost, and Steam Power Plant","PeriodicalId":7884,"journal":{"name":"Andalasian International Journal of Applied Science, Engineering and Technology","volume":"34 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Andalasian International Journal of Applied Science, Engineering and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25077/aijaset.v3i2.58","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract— Steam Power Plants are classified as thermal plants that convert chemical energy in fuel into electrical energy. In an effort to increase the effectiveness of the work of the plant, there needs to be proper planning for its operations, this is important because it directly affects the operational costs incurred by the plant. This journal aims to determine the effect of changes in load or variations in generator loading on power plant performance, both efficiency, heat rate and production costs of electricity generation and to identify the magnitude of the decline in the thermal performance of the generator, as well as determine the causes and parts of the plant whose performance level decreases compared to optimal conditions. The method used to calculate the efficiency and heat rate is the “Direct Method”, namely by directly comparing the input energy with the electrical output produced. The data used in this study is the “Power Plant Performance Test” data. The results of this study get the most optimal conditions when loading 93.39 MW Net with efficiency 34.693%, heat rate 2475,445 kcal/kWh and electricity production costs 413,297 Rp/kWh. The conclusion of this study is that plant performance is getting better at high loads. Keywords: Thermal efficiency, Heat Rate, Electricity Production Cost, and Steam Power Plant
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Ombilin 1号机组发电机负荷变化的电厂性能分析(2x100mw)
摘要:蒸汽发电厂是将燃料中的化学能转化为电能的热电厂。为了提高工厂的工作效率,需要对其运营进行适当的规划,这一点很重要,因为它直接影响到工厂的运营成本。本期刊旨在确定负荷变化或发电机负荷变化对发电厂性能的影响,包括发电效率、热率和生产成本,并确定发电机热性能下降的幅度,以及确定电厂性能水平与最佳条件相比下降的原因和部分。计算效率和热率的方法是“直接法”,即直接比较输入的能量和产生的电输出。本研究使用的数据为“电厂性能测试”数据。研究结果表明,负荷为93.39 MW时,发电效率为34.693%,发热量为2475,445 kcal/kWh,发电成本为413,297 Rp/kWh。本研究的结论是,在高负荷下,电厂的性能越来越好。关键词:热效率,热速率,发电成本,蒸汽电厂
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Determination of Resultant Forces for 2D Hyperstatic Frames using Android-Based Frame Design Application and Finite Element Analysis Enhancing Current Density and Specific Capacitance of Nata de Coco, TEMPO, and MXene Composites through Boiling Time Variations Integration of Photovoltaic Distributed Generation in Grid Distribution Network: A Literature Review Overcurrent and Directional Overcurrent Protection for Microgrid Study of Laccase Activity as a Biosensor for Peatland Degradation in Oil Palm Plantations in Pesisir Selatan of West Sumatra
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1