{"title":"3D modeling of bolus for producing by prototyping and use in radiation therapy","authors":"Larissa Cristina Silva dos Santos, J. W. Vieira, F. Lima, A. C. H. Oliveira","doi":"10.15392/2319-0612.2023.2220","DOIUrl":null,"url":null,"abstract":"Due to its vast number of occurrences, cancer has caused an economic impact on the public and supplementary health care sectors. It is estimated that more than 50% of patients diagnosed with malignant neoplasms need radiotherapy at some stage of their treatment, most of them treated with photon and/or electron beams. Due to the build-up effect (increase in dose in the matter from deposition on the surface to a point of maximum dose) caused by the interaction of photon beams with the irradiated tissue, bolus is often used in routine radiotherapy sectors to superficialize the point of maximum dose in the treatment region. The human body has complex surfaces that are often treatment regions in radiotherapy, but commercial bolus with a standard shape and length do not adapt perfectly to these surfaces. When this happens, air gaps may appear in the region, causing differences between the dose defined in radiotherapy planning and the dose delivered during treatment. In order to eliminate these air gaps and possible dose distribution errors, two methodologies for individualized bolus construction were proposed. In both cases, computed tomography images of the Alderson Rando male anthropomorphic phantom were used as a reference of the anatomy of a human body. From these images, one bolus model was constructed in the 3D modeling software 3ds Max by creating a polygonal mesh, while the other bolus model was constructed in the image computing software 3D Slicer, using segmentation tools. The software Creality Slicer 1.2.3. prepared the files for 3D printing. The prints of the files were made on polylactic acid filament on the Tevo Tarantula Pro printer. The bolus construction methodology using the software 3ds Max showed better results, as a greater contact area between the bolus and the phantom was observed when testing the fit of the printed bolus to the physical phantom. The 3D files of the virtual bolus will be available for future computer simulations. The printed bolus could be used in dosimetry with linear accelerators.","PeriodicalId":9203,"journal":{"name":"Brazilian Journal of Radiation Sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-07-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian Journal of Radiation Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15392/2319-0612.2023.2220","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Due to its vast number of occurrences, cancer has caused an economic impact on the public and supplementary health care sectors. It is estimated that more than 50% of patients diagnosed with malignant neoplasms need radiotherapy at some stage of their treatment, most of them treated with photon and/or electron beams. Due to the build-up effect (increase in dose in the matter from deposition on the surface to a point of maximum dose) caused by the interaction of photon beams with the irradiated tissue, bolus is often used in routine radiotherapy sectors to superficialize the point of maximum dose in the treatment region. The human body has complex surfaces that are often treatment regions in radiotherapy, but commercial bolus with a standard shape and length do not adapt perfectly to these surfaces. When this happens, air gaps may appear in the region, causing differences between the dose defined in radiotherapy planning and the dose delivered during treatment. In order to eliminate these air gaps and possible dose distribution errors, two methodologies for individualized bolus construction were proposed. In both cases, computed tomography images of the Alderson Rando male anthropomorphic phantom were used as a reference of the anatomy of a human body. From these images, one bolus model was constructed in the 3D modeling software 3ds Max by creating a polygonal mesh, while the other bolus model was constructed in the image computing software 3D Slicer, using segmentation tools. The software Creality Slicer 1.2.3. prepared the files for 3D printing. The prints of the files were made on polylactic acid filament on the Tevo Tarantula Pro printer. The bolus construction methodology using the software 3ds Max showed better results, as a greater contact area between the bolus and the phantom was observed when testing the fit of the printed bolus to the physical phantom. The 3D files of the virtual bolus will be available for future computer simulations. The printed bolus could be used in dosimetry with linear accelerators.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
三维建模丸的生产原型和使用在放射治疗
由于发病率高,癌症对公共和辅助保健部门造成了经济影响。据估计,超过50%被诊断为恶性肿瘤的患者在治疗的某个阶段需要放射治疗,其中大多数使用光子和/或电子束治疗。由于光子束与被照射组织的相互作用引起积聚效应(物质从表面沉积到最大剂量点的剂量增加),bolus通常用于常规放射治疗部门,以使治疗区域的最大剂量点表面化。人体具有复杂的表面,通常是放射治疗的治疗区域,但具有标准形状和长度的商业丸剂并不完全适应这些表面。当这种情况发生时,该区域可能出现气隙,造成放射治疗计划中确定的剂量与治疗期间给予的剂量之间的差异。为了消除这些气隙和可能的剂量分布误差,提出了两种个体化丸构建方法。在这两种情况下,计算机断层扫描图像的奥尔德森随机男性拟人化幻影被用作人体解剖的参考。从这些图像中,在三维建模软件3ds Max中通过创建多边形网格构建一个丸体模型,在图像计算软件3D Slicer中使用分割工具构建另一个丸体模型。软件质量切片1.2.3。准备3D打印的文件。文件的打印是在Tevo Tarantula Pro打印机上的聚乳酸长丝上进行的。使用3ds Max软件的丸构建方法显示出更好的结果,因为在测试打印丸与物理模体的贴合时,观察到丸与模体之间的接触面积更大。虚拟药丸的3D文件将可用于未来的计算机模拟。打印的小丸可用于线性加速器剂量测定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Análisis integral de visitas guiadas al reactor de investigación nuclear RA-6: perspectivas educativas, de investigación y sociales Development of a sample exchange system for irradiations in the BH-3 channel of the IEA-R1 reactor at IPEN Análise dos índices de exposição de exames de radiografia digital Multiphysics Computational Modeling of Nuclear Reactors Small Size Through the Coupling of Serpent Codes and Fluent Abordagens de blindagens baseadas em polímeros como uma solução prática na redução dos riscos radiológicos em operações de campo
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1