Identification of the principal selenium compounds in selenium-enriched natural sample extracts by ion-pair liquid chromatography with inductively coupled plasma- and electrospray ionization-mass spectrometric detection
M. Kotrebai, J. Tyson, P. Udén, M. Birringer, E. Block
{"title":"Identification of the principal selenium compounds in selenium-enriched natural sample extracts by ion-pair liquid chromatography with inductively coupled plasma- and electrospray ionization-mass spectrometric detection","authors":"M. Kotrebai, J. Tyson, P. Udén, M. Birringer, E. Block","doi":"10.1039/A902770J","DOIUrl":null,"url":null,"abstract":"Selenium-enriched garlic and yeast sample extracts and digests were analyzed using ion-pair high performance liquid chromatography (HPLC) with on-line inductively coupled plasma-mass spectrometric (ICP-MS) and electrospray ionization-mass spectrometric (ESI-MS) detection. The principal selenium compounds in these samples were identified as selenomethionine, and Se-adenosyl-selenohomocysteine in yeast, and γ-glutamyl-Se-methyl-selenocysteine and possibly γ-glutamyl-selenomethionine in garlic. The compounds identified account for 85 and 90% of the total selenium content of the yeast and the garlic samples, respectively. On-line HPLC-ESI-MS selected ion chromatograms (SIC) and mass spectra of selenium compounds extracted from selenium enriched samples are presented. Limits of quantification (LOQ, defined as S/N = 10) for HPLC-ICP-MS were in the range 10–50 ng mL–1 Se in the injected extracts. LOQ values for HPLC-ESI-MS were ca. 100 times higher than those of HPLC-ICP-MS.","PeriodicalId":7814,"journal":{"name":"Analytical Communications","volume":"48 1","pages":"249-252"},"PeriodicalIF":0.0000,"publicationDate":"1999-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"101","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Communications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1039/A902770J","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 101
Abstract
Selenium-enriched garlic and yeast sample extracts and digests were analyzed using ion-pair high performance liquid chromatography (HPLC) with on-line inductively coupled plasma-mass spectrometric (ICP-MS) and electrospray ionization-mass spectrometric (ESI-MS) detection. The principal selenium compounds in these samples were identified as selenomethionine, and Se-adenosyl-selenohomocysteine in yeast, and γ-glutamyl-Se-methyl-selenocysteine and possibly γ-glutamyl-selenomethionine in garlic. The compounds identified account for 85 and 90% of the total selenium content of the yeast and the garlic samples, respectively. On-line HPLC-ESI-MS selected ion chromatograms (SIC) and mass spectra of selenium compounds extracted from selenium enriched samples are presented. Limits of quantification (LOQ, defined as S/N = 10) for HPLC-ICP-MS were in the range 10–50 ng mL–1 Se in the injected extracts. LOQ values for HPLC-ESI-MS were ca. 100 times higher than those of HPLC-ICP-MS.