{"title":"Reverberating Asymmetric TEM Cell For Radiated EMC/V And SE Testing, 10 KHz-18 GHz","authors":"M. Crawford, B. Riddle","doi":"10.1109/ISEMC.1992.626079","DOIUrl":null,"url":null,"abstract":"This paper describes work in progress at the National Institute of Standards and Technology (NIST) to develop a single, integrated facility for electromagnetic compatibility/vulnerability (EMC/V) and shielding effectiveness (SE) testing over the frequency range of 10 kHz to 18 GHz. The facility consists of an asymmetric (offset center plate) TEM cell, 1.01 m x 1.20 m x 2.98 m in size, with two cavity mode tuners, configured as a TEM transmission line-driven, modestirred chamber. TEM test fields are generated in the chamber at frequencies below multimode cutoff (= 150 MHz), and mode-stirred test fields are generated at frequencies above multimode cutoff. The test volume in the cell is 0.5 m x 0.6 m x 0.6 m. The paper discusses the cell design, advantages and limitations for its use, the theoretical basis for its operation, and the experimental approach for its use in SE or EMC/V testing. Results are given of the evaluation of the cell's operational parameters including VSWR, E-field amplitude versus input power, tuners' effectiveness, and test volume E-field uniformity .","PeriodicalId":93568,"journal":{"name":"IEEE International Symposium on Electromagnetic Compatibility : [proceedings]. IEEE International Symposium on Electromagnetic Compatibility","volume":"59 1","pages":"206-213"},"PeriodicalIF":0.0000,"publicationDate":"1992-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE International Symposium on Electromagnetic Compatibility : [proceedings]. IEEE International Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.1992.626079","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
This paper describes work in progress at the National Institute of Standards and Technology (NIST) to develop a single, integrated facility for electromagnetic compatibility/vulnerability (EMC/V) and shielding effectiveness (SE) testing over the frequency range of 10 kHz to 18 GHz. The facility consists of an asymmetric (offset center plate) TEM cell, 1.01 m x 1.20 m x 2.98 m in size, with two cavity mode tuners, configured as a TEM transmission line-driven, modestirred chamber. TEM test fields are generated in the chamber at frequencies below multimode cutoff (= 150 MHz), and mode-stirred test fields are generated at frequencies above multimode cutoff. The test volume in the cell is 0.5 m x 0.6 m x 0.6 m. The paper discusses the cell design, advantages and limitations for its use, the theoretical basis for its operation, and the experimental approach for its use in SE or EMC/V testing. Results are given of the evaluation of the cell's operational parameters including VSWR, E-field amplitude versus input power, tuners' effectiveness, and test volume E-field uniformity .
本文描述了美国国家标准与技术研究所(NIST)正在进行的一项工作,即开发一个单一的集成设备,用于在10 kHz至18 GHz的频率范围内进行电磁兼容性/脆弱性(EMC/V)和屏蔽有效性(SE)测试。该设备由一个非对称(偏移中心板)TEM单元组成,尺寸为1.01 m x 1.20 m x 2.98 m,具有两个腔模式调谐器,配置为TEM传输线驱动的调制室。实验室内在多模截止频率以下(= 150 MHz)产生TEM试验场,在多模截止频率以上产生模搅拌试验场。细胞内的测试体积为0.5 m × 0.6 m × 0.6 m。本文讨论了电池的设计、使用的优点和局限性、工作的理论基础以及在SE或EMC/V测试中使用的实验方法。给出了单元工作参数的评估结果,包括VSWR、E-field振幅与输入功率的关系、调谐器的有效性和测试体积E-field均匀性。