ALTIROC 1, a 25 ps time resolution ASIC for the ATLAS High Granularity Timing Detector

C. Agapopoulou, P. Dinaucourt, A. Dragone, D. Gong, C. de La Taille, N. Makovec, B. Markovic, G. Martin-Chassard, C. Milke, M. Morenas, L. Ruckman, S. Sacerdoti, A. Schwartzman, N. Seguin-Moreau, L. Serin, D. Su, J. Ye
{"title":"ALTIROC 1, a 25 ps time resolution ASIC for the ATLAS High Granularity Timing Detector","authors":"C. Agapopoulou, P. Dinaucourt, A. Dragone, D. Gong, C. de La Taille, N. Makovec, B. Markovic, G. Martin-Chassard, C. Milke, M. Morenas, L. Ruckman, S. Sacerdoti, A. Schwartzman, N. Seguin-Moreau, L. Serin, D. Su, J. Ye","doi":"10.1109/NSS/MIC42677.2020.9507972","DOIUrl":null,"url":null,"abstract":"1 Abstract—Designed and characterized by the HGTD collaboration, ALTIROC belongs to the family of readout ASICs used at the Large Hadron Collider (LHC) for the High Luminosity-LHC upgrade. ALTIROC1 is a 25-channel ASIC designed in CMOS 130 nm to read out the 5 x 5 matrix of 1.3 mm x 1.3 mm Low Gain Avalanche Diodes (LGAD) of the ATLAS HGTD detector. The targeted combined time resolution of the sensor and its readout electronics from 35 ps/hit (initial) to 70 ps/hit (end of operational lifetime). Each ASIC channel integrates an RF preamplifier followed by a high speed discriminator and two TDCs for Time-of-Arrival and Time-Over-Threshold measurements as well as a local memory. This front-end must exhibit an extremely low jitter noise while keeping a challenging power consumption of less than 4.5 mW per channel. This conference proceeding summarizes the ASIC's architecture, its measured performances compared to simulation, along with the requirements for the HEP experiments.","PeriodicalId":6760,"journal":{"name":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","volume":"10 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSS/MIC42677.2020.9507972","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

1 Abstract—Designed and characterized by the HGTD collaboration, ALTIROC belongs to the family of readout ASICs used at the Large Hadron Collider (LHC) for the High Luminosity-LHC upgrade. ALTIROC1 is a 25-channel ASIC designed in CMOS 130 nm to read out the 5 x 5 matrix of 1.3 mm x 1.3 mm Low Gain Avalanche Diodes (LGAD) of the ATLAS HGTD detector. The targeted combined time resolution of the sensor and its readout electronics from 35 ps/hit (initial) to 70 ps/hit (end of operational lifetime). Each ASIC channel integrates an RF preamplifier followed by a high speed discriminator and two TDCs for Time-of-Arrival and Time-Over-Threshold measurements as well as a local memory. This front-end must exhibit an extremely low jitter noise while keeping a challenging power consumption of less than 4.5 mW per channel. This conference proceeding summarizes the ASIC's architecture, its measured performances compared to simulation, along with the requirements for the HEP experiments.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
ALTIROC 1,用于ATLAS高粒度定时检测器的25 ps时间分辨率ASIC
摘要:ALTIROC由HGTD合作设计和表征,属于大型强子对撞机(LHC)用于高亮度-LHC升级的读出asic家族。ALTIROC1是一款采用CMOS 130 nm设计的25通道ASIC,用于读取ATLAS HGTD探测器的1.3 mm x 1.3 mm低增益雪崩二极管(LGAD)的5 x 5矩阵。传感器及其读出电子器件的目标组合时间分辨率从35ps /命中(初始)到70ps /命中(运行寿命结束)。每个ASIC通道集成了一个RF前置放大器,随后是一个高速鉴别器和两个tdc,用于到达时间和超过阈值的测量,以及一个本地存储器。该前端必须具有极低的抖动噪声,同时保持每个通道低于4.5 mW的具有挑战性的功耗。本次会议总结了ASIC的架构,与仿真相比的测量性能,以及HEP实验的要求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Performance of Dual-Ended Readout PET Detectors Based on SiPMs with Different Microcell Sizes Neural Network-based Inter-crystal Scatter Event Positioning in a PET System Design Based on 3D Position Sensitive Detectors An e-LINAC driven PGNAA system for concealed drug inspection Design of a Multi-Technology Pre-Clinical SPECT System Comprehensive Simulation and Design of 3D Silicon Sensors for Enhanced Timing Performance
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1