Ultrasound transducer sensitivity in non linear parameter measurement

D. Kourtiche, M. Nadi, A. Rouane, A. Chitnalah
{"title":"Ultrasound transducer sensitivity in non linear parameter measurement","authors":"D. Kourtiche, M. Nadi, A. Rouane, A. Chitnalah","doi":"10.1109/ICSENST.2008.4757128","DOIUrl":null,"url":null,"abstract":"We present a procedure for measurement of the non linear B/A parameter using a simple comparative method. A theoretical model of the measurement system is proposed. A function sensitivity of the system is derived in order to connect the electric and acoustic magnitudes. Thus the optimal conditions in order to avoid complex calculation of the transducers sensitivities were carried out. We showed that the sensitivity function of the measurement system can be kept close to the unit by making a good choice of the fundamental frequency. Indeed if the frequency of the source transducer is chosen less than the resonance frequency we can avoid determining the sensitivities. Measurements had been carried out to validate the procedure and the theoretical aspects.","PeriodicalId":6299,"journal":{"name":"2008 3rd International Conference on Sensing Technology","volume":"20 1","pages":"358-362"},"PeriodicalIF":0.0000,"publicationDate":"2008-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 3rd International Conference on Sensing Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENST.2008.4757128","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

We present a procedure for measurement of the non linear B/A parameter using a simple comparative method. A theoretical model of the measurement system is proposed. A function sensitivity of the system is derived in order to connect the electric and acoustic magnitudes. Thus the optimal conditions in order to avoid complex calculation of the transducers sensitivities were carried out. We showed that the sensitivity function of the measurement system can be kept close to the unit by making a good choice of the fundamental frequency. Indeed if the frequency of the source transducer is chosen less than the resonance frequency we can avoid determining the sensitivities. Measurements had been carried out to validate the procedure and the theoretical aspects.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
超声换能器在非线性参数测量中的灵敏度
我们提出了用简单的比较法测量非线性B/ a参数的程序。提出了测量系统的理论模型。推导了系统的函数灵敏度,以便将电量值和声量值联系起来。为了避免传感器灵敏度的复杂计算,给出了最佳条件。结果表明,通过选择合适的基频,可以使测量系统的灵敏度函数与单元保持接近。事实上,如果选择源换能器的频率小于共振频率,我们可以避免确定灵敏度。已经进行了测量以验证程序和理论方面。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Synthesis and characterization of CuO nanoparticle: Its electrochemical paracetamol sensor activity and substituted-2-aminothiophene synthesis applications Electrochemical-sensor, antimicrobial and Environmental Assessments of Bi 3+ :Mg (1− x) Zr x O 4 NPs synthesized by bio-mediated combustion method CeO2/ZnO nanocomposite-modified glassy carbon electrode as an enhanced sensing platform for sensitive voltammetric determination of norepinephrine Mechanical and corrosion properties of electrochemically deposited Ni-Nb2O5 composite coatings on mild steel for marine Applications Voltammetric analysis of hazardous azo-dye indigo carmine at simple and cost-effective carbon paste sensor modified with L-phenylalanine
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1