{"title":"Detection of tracking carbon path using visual and thermal images (Discussion, with reply by M. Nishida et al.)","authors":"J. H. Mason, K. Mathes, B. Varlow, M. Nishida","doi":"10.1109/14.236203","DOIUrl":null,"url":null,"abstract":"The discussers separately address questions raised in the above-titled paper by M. Nishida et al. (ibid., vol.27, p.1050-1053, 1982) concerning tracking test procedures. The three discussers agree that there is a need to revise IEC 587. Nishida replies that the above paper did not intend to evaluate the tracking resistance of the electrical insulating materials, or to offer any information for a revision of IEC 587. >","PeriodicalId":13105,"journal":{"name":"IEEE Transactions on Electrical Insulation","volume":"16 1","pages":"425-428"},"PeriodicalIF":0.0000,"publicationDate":"1993-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Electrical Insulation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/14.236203","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
The discussers separately address questions raised in the above-titled paper by M. Nishida et al. (ibid., vol.27, p.1050-1053, 1982) concerning tracking test procedures. The three discussers agree that there is a need to revise IEC 587. Nishida replies that the above paper did not intend to evaluate the tracking resistance of the electrical insulating materials, or to offer any information for a revision of IEC 587. >